KITOZER
KITOZER

KITOZER Outdoor Power Cabinet 30 kVA With Battery Backup

The KITOZER 30 kVA outdoor power cabinet integrates an online double-conversion UPS, battery compartment, DC distribution, and AC output distribution in a single weatherproof enclosure for remote sites without a building. Designed for roadside 5G power shelters, traffic management intersections, pipeline pump stations, and off-grid telecom sites, the cabinet delivers conditioned, uninterrupted AC power to critical loads while surviving wide ambient temperature swings and dust exposure. A sealed battery bay with fire-rated separation protects staff and equipment during abnormal battery events. The all-in-one format eliminates the cost of building an equipment room and shortens site commissioning from weeks to days.

Product Overview

The cabinet is split into two compartments separated by a steel partition: the equipment bay houses the 30 kVA UPS module, input and output distribution, and monitoring controller; the battery bay accepts front-access valve-regulated lead-acid or lithium iron phosphate battery strings. The front door and rear door both lock independently, allowing battery service without exposing the power electronics. A plinth-mounted skid base supports concrete mounting and includes forklift slots for site delivery. A touchscreen HMI on the front door displays load percentage, battery state of charge, and alarm history, and remote communication allows energy managers to monitor the site from a central NOC.

Technical Specifications

Ingress protection IP55. Material 1.5mm galvanized steel with outdoor polyester powder coat, optional 304 stainless. UPS rating 30 kVA / 24 kW online double conversion, 3 phase input, single or three phase output, input power factor greater than 0.99, efficiency up to 95 percent in Eco mode. Battery bay configurable for up to 60 x 12V 100Ah VRLA batteries or equivalent lithium pack, supporting 30 minutes to 4 hours backup depending on load. Thermal management: 1500W outdoor air conditioner with redundant fans, 300W PTC heater, condensate evaporation tray. Monitoring: touchscreen HMI, SNMP, Modbus TCP, dry contacts, optional 4G remote. Dimensions 1200mm W by 800mm D by 2000mm H. KITOZER 3 year UPS warranty, 5 year enclosure warranty.

Applications

Primary uses include 5G macro site power shelters, intelligent transportation intersection cabinets, railway signaling backup power, water treatment plant remote power, oil and gas wellhead instrumentation power, and rural fiber access nodes. The cabinet also supports outdoor edge computing racks, temporary event power distribution, and disaster recovery mobile telecom huts where a permanent building is unavailable. Operators commonly parallel two cabinets for N plus 1 redundancy at critical sites, such as highway tunnel ventilation and broadcasting transceivers.

Advantages and Features

All-in-one design eliminates separate UPS room, battery room, and shelter construction. The integrated air conditioner prevents battery overheating, extending battery service life by maintaining 20 to 25 degree Celsius internal temperature. Fire-rated battery separation and optional gas exhaust duct contain internal thermal events. Parallel redundancy allows two cabinets to share load for N plus 1 availability. Wide input voltage tolerance handles poor grid quality typical of remote sites. The UPS supports generator compatibility with programmable voltage and frequency windows, preventing nuisance transfers during generator start-up.

Installation and Maintenance Recommendations

Place the cabinet on a level concrete plinth with drainage around the perimeter. Connect neutral and earth separately at the input, and verify grounding resistance below 5 ohms. Commission the UPS in bypass mode first, then transfer to online. Schedule quarterly battery voltage and internal resistance tests, annual battery capacity test, and semiannual air conditioner filter and condenser inspection. Keep the battery bay ventilated per battery manufacturer instructions and never store flammable materials within one meter of the cabinet. Firmware updates should be performed during a maintenance window with the load on bypass. Retain replacement batteries locally to minimize downtime during end-of-life replacement.

Customization and Quality

KITOZER offers lithium battery upgrade, expanded battery bay, parallel redundancy, 4G remote monitoring, and 316L stainless options. Every cabinet passes a factory FAT with full load bank test, battery charge cycle, and thermal run. Units ship with commissioning manuals, wiring diagrams, and test reports. Project customers receive dedicated engineering support for power study, load schedule, and backup runtime calculation.

Price

From $9,800 per unit excluding batteries. Contact KITOZER for battery configuration, backup runtime, and project pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com