KITOZER
KITOZER

KITOZER Parallel Cabinet For 4 Diesel Generators 1000kW

Product Overview

The KITOZER parallel cabinet for four diesel generators is a medium-voltage synchronization and load-sharing switchboard designed for plants that need redundant megawatt-class power. The cabinet accepts four generator incoming feeders, synchronizes them with the utility bus or with each other, and distributes total capacity up to 4000kW through outgoing feeders. Built around a deep-sea or ComAp load-share controller, the cabinet handles soft synchronization, kW load sharing, load shedding, and black start sequencing. KITOZER engineers the cabinet with air circuit breakers, busbar measurement, protection relays, and human-machine interface, so the customer only needs to connect generator cables, utility feeders, and outgoing loads.

Technical Specifications

Rated for four 1000kW generators at 400V or 480V, 50Hz or 60Hz. Each generator incoming is fitted with a 2000A air circuit breaker with protection relays for overcurrent, short circuit, and reverse power. The utility feeder is fitted with a 3200A circuit breaker, and outgoing feeders are sized per customer schedule. The controller performs synchronization within plus or minus 5 degrees phase angle, plus or minus 0.5Hz frequency, and plus or minus 5 percent voltage. Load sharing is within plus or minus 5 percent per unit. The cabinet measures voltage, current, kW, kVA, kVAR, PF, frequency, and energy on every feeder. Busbar temperature monitoring, fan cooling, and arc-flash venting are standard. Communication: Modbus TCP, Ethernet, SNMP, and optional GSM. Cabinet is floor-standing IP42, steel powder coated, with HMI touch screen on the front door. Weight is about 2800kg and dimensions are 2400 by 800 by 2200 millimeters.

Applications

This parallel cabinet is used in medium data centers where four 1000kW generators run in parallel to feed UPS systems and cooling plants. Hospitals and university campuses deploy it to achieve N plus one redundancy, so that one generator can be serviced without losing site power. Industrial plants with heavy production lines use it to share load across multiple gensets and shed non-critical loads during peak demand. Microgrid and distributed energy projects also use it to synchronize diesel generators with solar and battery storage. Because the cabinet handles load sharing and synchronization automatically, operators do not need to manually match phases and frequencies.

Advantages and Features

KITOZER builds the parallel cabinet with industrial-grade components: air circuit breakers with motorized spring charge, protection relays, current transformers, and voltage transformers. The controller offers automatic start sequencing, synchronization, load sharing, load shedding, and stop sequencing with cool-down timers. A human-machine interface displays one-line diagram, feeder status, metering, and alarm history. Standard features: Modbus TCP, Ethernet, SNMP, dry-contact alarms, fan cooling, busbar temperature monitoring, and arc-flash venting. Optional items include GSM remote monitoring, synchroscope mimic diagram, generator power management software, and third-party communication protocol such as IEC 61850. The cabinet is factory-tested with simulated signals before shipment, and KITOZER provides commissioning support on site.

Installation and Maintenance Recommendations

Install the cabinet on a level concrete plinth, anchor it with floor bolts, and keep 1 meter clearance on front and rear for cable termination and door swing. Connect generator cables, utility feeder, and outgoing feeders with copper busbar or cable lugs sized per current rating. Verify phase rotation on every feeder before energizing. Configure the controller with generator ratings, load priority, and load shedding thresholds, and perform synchronization tests with one generator at a time before paralleling all four. Maintenance: circuit breaker spring mechanism inspection annually, protection relay test every 2 years, current transformer ratio check every 4 years, fan filter cleaning quarterly, and battery replacement for the controller every 3 years. Keep the cabinet door closed to prevent dust ingress, and verify arc-flash venting is not obstructed. Remote monitoring via Modbus TCP or GSM helps operators track breaker status, load share, and alarm history.

Typical Customer Configuration

A typical KITOZER parallel cabinet configuration for four 1000kW generators includes outgoing feeders for main switchboard, UPS system, cooling plant, and essential lighting. The controller is set for N plus one redundancy, so that any single generator can be serviced or fail without losing site power. Load shedding logic automatically removes non-critical loads if total demand exceeds available capacity. This package is widely specified by data centers, hospitals, and industrial plants that require megawatt-class redundancy.

Quality Assurance and Delivery

KITOZER performs a full factory test on each parallel cabinet, including insulation resistance, contact resistance, protection relay simulation, synchronization logic, load-share balance, and communication protocol verification. The one-line diagram, wiring schedule, and protection settings are documented in the factory test report. Delivery scope includes the parallel cabinet, controller manual, electrical schematic, spare relay kit, and 2 years of warranty. KITOZER can supply outgoing feeders, power management software, and on-site commissioning with the customer generator set. CE documentation, type test report, and factory witness test are available for large data center and utility projects.

Price

From $58,000 per parallel cabinet ex works Guangzhou. Contact KITOZER for custom one-line diagram, outgoing feeder schedule, and commissioning support.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart