Table of Contents
ToggleProduct Overview
The KITOZER 400A PC class automatic transfer switch is a single-unit, three-source-capable change-over appliance designed for medium commercial and industrial installations where utility, generator, and optional alternate utility must be selected automatically. PC class means the switching element is a dedicated change-over device rated to carry and withstand short-circuit current, unlike CB class which uses two circuit breakers. This gives the KITOZER PC ATS a smaller footprint, faster transfer, and lower cost than equivalent CB class equipment, while still providing full short-circuit withstand capability. The electromechanical drive operates under 200ms between sources, and the controller monitors voltage, frequency, and phase on both feeds with programmable windows and timers. A manual operating handle allows safe mechanical selection during maintenance, and the built-in interlock guarantees that the two sources can never be paralleled.
Technical Specifications
Rating: 400A continuous, 400V three phase plus neutral, 50 or 60Hz. Class: PC class IEC 60947-6-1, dedicated change-over switch, short-time withstand rated. Transfer time: 100ms to 200ms typical. Source monitoring: three phase under voltage, over voltage, unbalance, frequency, phase rotation on both feeds. Voltage window programmable 320V to 460V, frequency 47Hz to 63Hz. Timers: generator start delay, transfer delay, re-transfer delay, preferred source. Control: microprocessor controller with LCD, front push buttons, event log. Communication: RS485 Modbus RTU standard, optional Ethernet Modbus TCP, optional SNMP, dry contact IO. Mechanical: motor driven change-over, manual handle, electrical and mechanical interlock. Mounting: floor standing or wall cabinet, IP31, operating -5 to 40 degrees C. Standards: CE, IEC 60947, 5 year warranty.
Application Scenarios
The 400A PC ATS is the typical interface between a 400A automatic standby generator and a commercial building or medium industrial plant. Common sites include hotels, shopping centers, mid-rise office buildings, hospitals without full UPS-grade critical loads, water treatment plants, pumping stations, and food and beverage processing lines. It is also used in large retail distribution centers, cold storage warehouses, and data halls that use UPS for the short transfer gap but rely on the ATS for long-duration generator power. In telecom and broadcasting, it selects between utility and generator for transmission sites. In solar plus storage microgrids, it can switch the building feed between grid and inverter under controller logic.
Key Advantages
PC class gives a smaller footprint and faster transfer than CB class at the same current rating, which saves switchroom floor space and reduces the number of contact operations during utility dips. The dedicated change-over switch is rated for short-time withstand, so no separate upstream coordination study is needed beyond the main breaker. The motor drive with manual handle allows live mechanical operation during maintenance. The interlock is both electrical and mechanical, so software bugs cannot cause source paralleling. Adjustable timers prevent nuisance generator starts during short utility flickers. Modbus and optional SNMP integrate the ATS into BMS, DCIM, and generator management platforms. The LCD event log gives service technicians a local record of every transfer and fault, reducing truck rolls to diagnose problems.
Installation and Maintenance Recommendations
Mount on a solid floor plinth or wall bracket rated for the cabinet weight, size upstream and downstream busbar for 400A with appropriate derating, and coordinate the main upstream breaker with the ATS short-time withstand rating. On commissioning, set voltage and frequency windows, set generator start delay to match the engine, set transfer delay to let generator voltage stabilize, and set re-transfer delay for generator cool-down. Run a forced transfer on each source with real load. Verify that the mechanical handle cannot engage both sources. Maintenance: inspect contacts annually for pitting, torque terminals, test the manual handle, read event log, and exercise the motor drive. Keep a spare control board and motor drive on site. Because PC class contacts do wear, budget a contact inspection every 5 years and a contact replacement after a high number of operations or after a short-circuit event. Trend source voltage to catch generator and utility issues early.
Ordering Information
The 400A PC ATS is supplied as a floor standing cabinet with busbar top or bottom entry, or as an open frame for integration into a new switchboard. The standard controller includes LCD, event log, RS485 Modbus RTU, and adjustable timers. Optional packages include Ethernet Modbus TCP, SNMP for BMS integration, a generator start output with crank control, and a manual operating handle with padlock facility. The cabinet can be supplied IP31 or IP42, and busbar stubs can be prefabricated to site drawings. Lead time is four to six weeks for standard configurations. KITOZER provides factory test reports, a coordination study support, and commissioning guidance. The five year warranty covers both the change-over switch and the controller.
Price
From $3,680 per piece. Contact the factory for cabinet layout, generator interface, and Modbus TCP option. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com