The KITOZER 50kW power conversion system is a three-phase bi-directional inverter that links a lithium battery rack to the low-voltage AC grid, enabling peak shaving, demand charge management, backup power, and self-consumption optimization. Using three-level IGBT topology and LCL filtering, the PCS achieves up to 98.5 percent maximum efficiency and supports both grid-tied and islanded operation modes. It is a compact tower unit designed for commercial and industrial energy storage projects, and it can be paired with KITOZER battery cabinets to form a complete turnkey storage system.
Table of Contents
ToggleProduct Overview
KITOZER 50kW PCS integrates DC to AC conversion, grid synchronization, anti-islanding, reactive power support, and DC bus protection in a single wall or floor-standing enclosure. The controller communicates with the battery management system via CAN bus and with the site energy management system via Modbus TCP, coordinating charge and discharge schedules in real time. A built-in contactor and pre-charge circuit protect the DC bus at startup, and a DC main breaker allows safe isolation for service.
The power stage uses a three-level neutral-point-clamped topology that reduces harmonic content and filter size compared with two-level designs. The controller runs a real-time operating system and executes setpoints from the EMS every 10 milliseconds. On loss of grid voltage, the PCS switches to grid-forming mode in under 20 milliseconds, supplying connected critical loads from the battery. The front touchscreen displays power, state of charge, and fault history in plain language.
Technical Specifications
Rated AC power 50kW, 400V three phase, 50/60Hz. DC voltage range 600 to 850V. Maximum efficiency 98.5 percent, European efficiency 98.2 percent. THDi under linear load less than 3 percent. Power factor 0.8 leading to 0.8 lagging adjustable. Protection IP20, operating temperature -25 to +60 degrees Celsius, derating above 40. Noise less than 65dB at 1m. Dimensions 600x500x1200mm, weight 95kg. Communication: CAN to BMS, Modbus TCP and RS485 to EMS, dry contact alarms. Certifications CE, IEC 62109, VDE-AR-N 4105 optional. KITOZER brand, 5-year warranty.
Applications
This PCS is suited for commercial and industrial battery energy storage systems behind the meter, peak shaving factories, shopping malls, and logistics centers. It supports demand charge reduction, renewable self-consumption, and backup power for critical loads during outages. It can also be paralleled up to 8 units for larger C&I storage projects, and it integrates with rooftop PV to shift solar generation from midday to evening peak hours.
Advantages and Features
Bi-directional IGBT design supports four-quadrant operation, providing both active and reactive power control. The three-level topology reduces filter size and improves harmonic performance. Soft-start and anti-islanding functions ensure compliant grid behavior. A color touchscreen HMI displays real-time power, state of charge, and fault logs. Remote firmware update via Ethernet reduces service visits. Parallel operation with droop control allows seamless scaling from one to eight units.
The PCS offers built-in grid support functions including volt-var, frequency-watt, and ramp-rate control, which are increasingly required by grid operators. The DC side includes a pre-charge resistor and contactor that limit inrush current when connecting the battery, protecting both the PCS and the battery contactors. A built-in DC insulation monitoring device warns the operator if the battery or cabling develops an earth fault. The unit also supports scheduled charge and discharge based on time-of-use tariffs, maximizing arbitrage revenue.
Installation and Maintenance
Install in a ventilated, dust-free room with ambient temperature below 40 degrees Celsius for full rating. Maintain 500mm clearance on both sides for airflow. Connect battery DC cables with correct polarity and use shielded cables for CAN communication, routed separately from power cables. Verify grid voltage and frequency settings before first charge. Never operate the PCS without the battery management system communication link active, because the BMS provides the charge and discharge current limits.
Maintenance includes annual fan filter cleaning, DC busbar torque check, and insulation resistance test. Keep firmware updated with releases issued by KITOZER. Every two years, inspect the DC contactors for pitting and replace if contact resistance has risen. Keep a log of daily charge and discharge energy to detect gradual efficiency loss. If a fault occurs, record the fault code from the HMI and send it to KITOZER support before attempting a reset.
Quality and Reliability
KITOZER PCS units pass a full load burn-in test for 4 hours at rated power before shipment, with thermal imaging of all power semiconductors. The controller firmware is validated against a hardware-in-the-loop test rig that simulates grid faults, islanding, and battery faults. Every unit includes a commissioning report and a quick-start guide in English. The cooling fans are rated for 60,000 hours at nominal ambient, and the electrolytic DC bus capacitors are sized for 10-year design life at 40 degrees Celsius ambient.
Price
From $6,980/pc. Contact +86 13922289957 for PCS pricing and parallel configuration support for your storage project.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com