KITOZER Piped Gas Fire Suppression Solution for Computer Rooms

Table of Contents

1. System Introduction

The piped gas fire suppression system is an efficient, eco-friendly and safe fixed fire extinguishing system. It delivers extinguishing agents to designated protected areas via professionally designed pipe networks to achieve total flooding fire suppression. Specially applicable to computer rooms, data centers, power distribution rooms and other environments with high-value electronic equipment sensitive to water damage, the system can put out fires rapidly without causing any damage to equipment or personnel, serving as the preferred fire protection solution for modern computer rooms.

The KITOZER piped gas fire suppression system is designed and manufactured in strict accordance with national standards including Code for Design of Gas Fire Extinguishing Systems (GB50370-2005) and Code for Construction and Acceptance of Gas Fire Extinguishing Systems (GB50263-2007). It offers two mainstream extinguishing agents: HFC-227ea (Heptafluoropropane) and IG541 mixed gas, meeting the fire protection demands of diverse computer room scenarios. Equipped with three activation modes—automatic, manual and emergency manual, the system ensures reliable startup and rapid fire spread control under all emergencies.

2. System Composition

The KITOZER piped gas fire suppression system consists of multiple core components that work in coordination to ensure efficient and reliable system operation:

2.1 Extinguishing Agent Storage Device

Composed of agent cylinders, cylinder valves, drive gas cylinders and electromagnetic actuators, it stores fire extinguishing agents and drive gas to provide startup power for the entire system.

2.2 Pipe Network Delivery System

Consisting of manifold pipes, selector valves (for combined distribution systems), connecting pipes, check valves, pressure reducing devices and safety valves, it evenly transports extinguishing agents to each protected area and precisely controls gas flow direction and working pressure.

2.3 Injection System

Including spray nozzles, it atomizes and uniformly distributes extinguishing agents to form a full flooding effect and eliminate fire blind spots in protected spaces.

2.4 Control & Alarm System

Composed of fire alarm controllers, gas fire suppression controllers, smoke/heat detectors, manual control boxes, emergency start/stop buttons, audible and visual alarms, and gas release indicators, it realizes fire detection, alarm notification and system startup control, and guarantees safe personnel evacuation.

2.5 Auxiliary Facilities

Including pressure relief devices, gas check valves, low-leakage high-seal valves, pressure switches and signal feedback devices, it balances the pressure of protected areas, prevents gas backflow and feeds back real-time system operating status.

2.6 Supporting Accessories

Including cylinder brackets, pipe supports, pipe fittings, valves, pressure gauges and agent charging interfaces, it ensures firm system installation, reliable connection and convenient daily maintenance.

the computer room has a piped gas fire suppression system (7)

3. System Classification

3.1 Classification by Extinguishing Agent Type

3.1.1 HFC-227ea (Heptafluoropropane) Piped Fire Suppression System

Featuring high fire extinguishing efficiency, clean and eco-friendly performance, non-conductivity, zero residue and low toxicity, it is applicable to computer rooms, server rooms, UPS rooms and precision instrument rooms.

3.1.2 IG541 Mixed Gas Piped Fire Suppression System

Composed of 52% nitrogen, 40% argon and 8% carbon dioxide, it is a pure natural, non-toxic and eco-friendly gas mixture. It is ideal for manned computer rooms, archives, libraries, cultural relic museums and other scenarios with strict personnel safety requirements.

3.2 Classification by Structural Characteristics

3.2.1 Independent Unit System

One set of storage devices corresponds to a single protected area, featuring strong independence and high reliability. It is suitable for core computer rooms, high-risk areas and spaces requiring independent fire protection.

3.2.2 Combined Distribution System

One set of storage devices protects multiple adjacent protected areas via selector valves, effectively reducing equipment investment costs. It is widely used for centrally managed areas such as clustered computer rooms and power distribution centers.

3.3 Classification by Working Pressure Type

3.3.1 Internal Pressure-stored HFC-227ea System

With working pressure of 4.2MPa/5.6MPa, it features simple structure and low maintenance difficulty, suitable for medium and short-distance agent delivery scenarios.

3.3.2 External Pressure-stored HFC-227ea System

With working pressure of 4.2MPa/5.6MPa and a maximum delivery distance of 243m, it adapts to large-scale data centers and long-distance pipe network systems.

3.3.3 High-pressure IG541 Mixed Gas System

With a rated working pressure of 15MPa (20℃), it delivers stable and efficient fire suppression performance, applicable to all types of computer rooms, especially manned scenarios.

the computer room has a piped gas fire suppression system (6)

4. System Schematic & Working Principle

4.1 Working Principle of Independent Unit System

Signal Logic: Smoke & Heat Detectors → Gas Fire Suppression Controller → Audible & Visual Alarm + Gas Release Indicator Control Linkage: Electromagnetic Actuator → Drive Gas Cylinder → Cylinder Valve → Agent Cylinder → Manifold Pipe → Pipe Network → Nozzles → Protected Area Status Feedback: Pressure Switch → Feedback Signal → Controller → Linked Control (Air conditioner/ventilation shutdown, power cut-off) Manual Intervention: Manual Control Box (Emergency Start/Stop Button) for direct system control

Working Flow

1. Once a fire occurs, both smoke and heat detectors trigger alarms and transmit signals to the gas fire suppression controller.

2. The controller activates audible and visual alarms, starts an adjustable 0-30s delay, and synchronously cuts off power supply and shuts down ventilation and air-conditioning systems via linkage control.

3. After the delay ends, the controller outputs signals to activate the electromagnetic actuator and trigger the drive gas cylinder.

4. The drive gas opens the cylinder valve, and the extinguishing agent is delivered to nozzles through manifold pipes and pipe networks for full flooding release in the protected area.

5. The pressure switch detects gas flow and feeds back a release signal to the controller to display system operating status.

6. Operators can manually stop the system during the delay period or manually activate the system when automatic control fails.

4.2 Working Principle of Combined Distribution System

Signal Logic: Multi-area Detectors → Gas Fire Suppression Controller → Selector Valve Control Module → Target Area Selector Valve Suppression Linkage: Electromagnetic Actuator → Drive Gas Cylinder → Cylinder Valve → Agent Cylinder → Manifold Pipe → Opened Selector Valve → Target Area Pipe Network → Nozzles Isolation Design: Selector valves of non-fire areas remain closed to prevent agent leakage

Working Flow

1. When a fire breaks out in a single protected area, local detectors send alarm signals to the controller.

2. The controller identifies the fire location, activates the corresponding selector valve module and opens the target area valve.

3. The subsequent startup procedure is consistent with the independent unit system; the extinguishing agent is only released to the fire-affected area without impacting other protected zones.

4. The system supports simultaneous protection of multiple areas, with the agent storage capacity configured based on the maximum demand of a single protected area.

the computer room has a piped gas fire suppression system (5)

5. Core Technical Parameters

5.1 Technical Parameters of HFC-227ea Piped Fire Suppression System

Extinguishing Agent: HFC-227ea (Heptafluoropropane) with purity ≥99.8%, complying with GB18614-2012

Working Pressure: 4.2MPa / 5.6MPa (20℃), internal pressure-stored design

Filling Density: ≤950kg/m³ (4.2MPa system); ≤1080kg/m³ (5.6MPa system) for safe operation

Discharge Time: ≤10s for total flooding fire suppression, complying with GB50370-2005

Design Extinguishing Concentration: ≥8% (volume ratio) for computer rooms and server rooms; the design concentration is 1.3 times the minimum extinguishing concentration

Soaking Time: ≥5 minutes to ensure complete fire extinction and prevent re-ignition

Operating Temperature: 0℃~+50℃ (special customization required for out-of-range environments)

Activation Modes: Automatic, manual and emergency manual triple control for reliable startup under all conditions

Protected Area Limitation: Single area ≤800㎡, volume ≤3600m³; enclosure fire resistance ≥0.5h, compressive strength ≥1200Pa

Pipe Material: Internal and external galvanized seamless steel pipe, working pressure ≥2.5MPa, complying with GB50263-2007

Pipe Connection: Threaded connection for DN≤50mm pipes; flange connection for DN>50mm pipes to avoid inner wall corrosion caused by welding

Nozzle Protection Radius: 3.6m for standard diffusion nozzles to ensure uniform agent distribution

5.2 Technical Parameters of IG541 Mixed Gas Piped Fire Suppression System

Extinguishing Agent: Pure natural IG541 mixture (52% Nâ‚‚, 40% Ar, 8% COâ‚‚), non-toxic and pollution-free, complying with GB20128-2006

Working Pressure: 15MPa (20℃), maximum working pressure 17.2MPa (high-pressure storage for stable delivery and injection)

Discharge Requirements: The discharge time for 95% of the designed agent volume is 48s~60s, complying with GB50370-2005

Design Extinguishing Concentration: ≥37.5% (volume ratio) for computer rooms; the design concentration is 1.3 times the minimum extinguishing concentration

Soaking Time: ≥10 minutes for thorough fire extinction and re-ignition prevention

Operating Temperature: 0℃~+50℃ (special customization required for out-of-range environments)

Activation Modes: Automatic, manual and emergency manual triple control

Protected Area Limitation: Single area ≤800㎡, volume ≤3600m³; enclosure fire resistance ≥0.5h, compressive strength ≥1200Pa

Pipe Material: Stainless steel or seamless steel pipe, working pressure ≥15MPa

Pipe Connection: Flange connection as the main method to eliminate high-pressure leakage risks of threaded connections

Nozzle Protection Radius: 4.5m for special uniform distribution nozzles suitable for large-area protected spaces

5.3 Control & Alarm System Parameters

Gas Fire Suppression Controller: Operating voltage AC220V±10%, 50Hz; backup power DC24V 7Ah battery; supports 1-8 protected areas and RS485 communication interface

Detectors: Smoke detector sensitivity: 0.65-1.3μA/m; heat detector response temperature: 57℃/68℃ optional; intelligent self-diagnosis function

Manual Control Box: DC24V working voltage, starting current ≤0.5A, IP65 protection grade

Audible & Visual Alarm: Sound level ≥85dB (1m distance), flash frequency 1-2Hz, IP30 protection grade

Gas Release Indicator: DC24V working voltage, brightness ≥200cd/m², constant lighting for status prompt

Pressure Switch: Working pressure 0.1-1.0MPa, outputs normally open/closed passive contact signals for flow detection and status feedback

the computer room has a piped gas fire suppression system (4)

6. Application Scope

With high fire extinguishing efficiency, clean performance and zero equipment damage, the KITOZER piped gas fire suppression system is widely applied in the following scenarios, especially computer rooms and precision electronic equipment environments:

6.1 Data Center & Computer Room Scenarios

Electronic computer rooms, server rooms, network rooms, IDC data centers, UPS rooms, battery rooms, power distribution rooms, generator rooms, communication equipment rooms, program-controlled switching rooms and satellite communication centers

6.2 Precision Instrument & Valuable Asset Scenarios

Precision instrument rooms, laboratories, metering centers, archives, libraries, cultural relic museums, bank vaults, securities trading centers and high-value goods warehouses

6.3 Industrial & Commercial Key Areas

Integrated circuit production workshops, semiconductor clean rooms, pharmaceutical production workshops, operating rooms, medical device rooms, rail transit control centers, airport command centers and scheduling centers

6.4 Special Scenarios

Manned key areas (IG541 system priority), water-damage sensitive areas, and sites inaccessible to water-based fire suppression systems

the computer room has a piped gas fire suppression system (3)

7. Core Product Advantages

7.1 Superior Fire Suppression Performance

Efficient and rapid fire extinction: HFC-227ea features low design concentration (≥8% for electronic equipment areas) and ultra-fast discharge within 10 seconds; IG541 ensures reliable fire suppression with long soaking time to prevent re-ignition. Professional pipe network and nozzle design realizes full flooding coverage without fire blind spots. Triple startup modes ensure timely system response under all emergency conditions.

7.2 High Safety & Environmental Friendliness

Both HFC-227ea and IG541 are clean gas agents with zero residue and no environmental pollution after discharge. HFC-227ea is low-toxic and harmless to human bodies at design concentration; IG541 adopts pure natural gas components, fully suitable for manned scenarios. All agents are non-conductive, completely avoiding short-circuit damage to precision electronic equipment and adapting to computer room operating environments.

7.3 High System Reliability

High-strength seamless steel and stainless steel materials ensure safe high-pressure operation. All products undergo 100% pressure testing (1.5 times working pressure) and leakage testing before delivery to guarantee sealing performance. The intelligent controller supports real-time self-diagnosis, actively detecting potential faults and ensuring stable long-term operation.

7.4 Economic Efficiency & Low Maintenance

The combined distribution design enables one system to serve multiple protected areas, greatly reducing equipment investment costs for clustered computer rooms. Standardized modular components simplify daily inspection and part replacement, lowering maintenance difficulty. The service life of agent cylinders reaches 20 years, reducing replacement frequency and long-term operating costs.

7.5 Customized & Expandable Design

Two optional agents (HFC-227ea & IG541) meet differentiated scenario demands. Personalized solutions are available based on computer room area, volume and number of protected areas. The system can be integrated with automatic fire alarm systems and security systems to realize intelligent unified management.

the computer room has a piped gas fire suppression system (2)

8. Bidding Specification Parameters

8.1 Basic System Requirements

1. The system shall comply with national standards: GB50370-2005 Code for Design of Gas Fire Extinguishing Systems and GB50263-2007 Code for Construction and Acceptance of Gas Fire Extinguishing Systems.

2. Extinguishing agents shall meet national standards: HFC-227ea complies with GB18614-2012; IG541 complies with GB20128-2006.

3. The system shall possess valid national fire product certification, inspection reports and complete type approval documents.

8.2 Agent Storage Device Parameters

1. Agent cylinders adopt seamless steel cylinders complying with GB5099, with wall thickness ≥5mm and volume error ≤±2%.

2. Cylinder valves are made of stainless steel, supporting both automatic and manual startup, with sealing performance complying with GB25972-2024.

3. Working pressure tolerance: ±5% for 4.2MPa/5.6MPa HFC-227ea systems and 15MPa IG541 systems.

4. Filling density complies with GB50370-2005: ≤950kg/m³ (4.2MPa HFC-227ea); ≤1080kg/m³ (5.6MPa HFC-227ea).

8.3 Pipe Network & Injection System Parameters

1. Manifold pipes adopt seamless steel pipes with wall thickness ≥4mm, with welding quality complying with GB50236 and free of pores and slag inclusions.

2. Selector valves adopt cast steel material with excellent sealing performance, opening pressure ≤0.05MPa, complying with GB25972-2024.

3. Diffusion nozzles: protection radius ≥3.6m (HFC-227ea), ≥4.5m (IG541), injection angle ≥120°.

4. Pipes: Galvanized seamless steel pipes for HFC-227ea systems; stainless steel pipes for IG541 systems, complying with GB/T8163.

8.4 Control & Alarm System Parameters

1. Gas fire suppression controller: AC220V±10% working voltage, DC24V backup power, controllable protected areas ≥4, equipped with RS485 communication interface.

2. Detectors: Smoke detector response time ≤10s, heat detector response time ≤5s, with self-diagnosis function and annual false alarm rate ≤0.1%.

3. Manual control box: IP65 protection grade, button operation life ≥10,000 times, with misoperation prevention function.

4. Audible & visual alarm: Sound level ≥85dB (1m distance), flash frequency 1-2Hz, IP30 protection grade.

8.5 System Performance Parameters

1. Discharge time: ≤10s for HFC-227ea systems; 48-60s for 95% agent discharge of IG541 systems.

2. Extinguishing concentration: ≥8% (HFC-227ea for electronic areas), ≥37.5% (IG541 for electronic areas), complying with GB50370-2005.

3. Soaking time: ≥5 minutes (HFC-227ea), ≥10 minutes (IG541) for thorough fire extinction.

4. System reliability: MTBF (Mean Time Between Failures) ≥50,000 hours, startup success rate ≥99.9%.

the computer room has a piped gas fire suppression system (1)

9. Customized Industry Solutions

9.1 Small Computer Room Solution (Area ≤200㎡, Volume ≤600m³)

Applicable Scenarios: Small enterprise computer rooms, branch bank computer rooms, school computer rooms

Solution Design: Adopt 4.2MPa internal pressure-stored HFC-227ea piped system with independent unit design. Equip 1-2 sets of 70L/90L agent cylinders according to protected volume. Adopt 50-80mm seamless steel pipes with balanced pipe network design for uniform nozzle flow rate. Configure 1 set of gas suppression controller, 2-4 smoke/heat detectors and 1 outdoor manual control box. Install 1 pressure relief device at 2/3 of the room’s net height.

Core Advantages: Simple system structure, cost-effective investment, low maintenance cost, fully meeting basic fire protection and equipment safety requirements for small-scale computer rooms.

9.2 Medium Computer Room Solution (Area 200-500㎡, Volume 600-1800m³)

Applicable Scenarios: Medium enterprise computer rooms, Internet enterprise computer rooms, modular data centers

Solution Design: Adopt 4.2MPa/5.6MPa internal pressure-stored HFC-227ea system with combined distribution design to cover 2-4 protected areas. Equip 2-4 sets of 120L/150L cylinders configured based on the maximum protected area demand. Adopt 80-100mm seamless steel pipes with selector valves for independent flow control of each area. Configure dedicated manual control boxes and gas release indicators for every protected area, matched with pressure switch status feedback and independent pressure relief devices.

Core Advantages: One set of system covers multiple areas, effectively reducing procurement and construction costs while ensuring consistent fire suppression effect for all zones, ideal for centrally managed clustered computer rooms.

9.3 Large Data Center Solution (Area ≥500㎡, Volume ≥1800m³)

Applicable Scenarios: Large-scale data centers, cloud computing centers, financial core data centers

Solution Design: Adopt 15MPa high-pressure IG541 mixed gas piped system with combined distribution design for 4-8 protected areas. Equip 4-8 sets of 80L cylinders with 100% standby backup cylinders for ultra-high reliability. Adopt stainless steel pipes with full flange connection to adapt to high-pressure and long-distance delivery. Deploy master and regional controllers, matched with intelligent smoke/heat/image detectors for early fire warning. Equip independent pressure relief devices and gas concentration monitoring systems for each area, and integrate with BMS systems to realize unified fire safety, security and environmental monitoring management.

Core Advantages: Pure natural and non-toxic IG541 agent ensures personnel safety for long-term manned large data centers. High-pressure long-distance delivery adapts to large-space scenarios, and the combined distribution structure optimizes overall project cost with standby cylinders guaranteeing zero failure operation.

9.4 Manned Computer Room Solution

Applicable Scenarios: Communication computer rooms, power dispatching centers, medical equipment rooms and other long-term manned key areas

Solution Design: Adopt IG541 mixed gas piped system (independent or combined distribution design). Configure agent capacity strictly based on protected volume to meet standard discharge time requirements. Increase emergency start/stop buttons for full coverage of operating positions, and extend alarm delay to 15-30s for sufficient evacuation time. Equip real-time gas concentration monitoring systems to guarantee personnel safety. Provide professional operation training and regular emergency drills for on-site staff.

Core Advantages: The non-toxic and harmless characteristics of IG541 perfectly resolve the conflict between fire suppression efficiency and personnel safety, achieving dual protection of equipment assets and on-site staff.

10. Project Application Cases

10.1 Case 1: Internet Enterprise Data Center Project (Guangzhou)

Project Overview: The data center covers a construction area of 3200㎡, divided into 8 independent protected areas (400㎡ per area), hosting 24-hour uninterrupted server racks, network and storage equipment with high fire safety requirements.

Adopted Solution: Deploy KITOZER 5.6MPa internal pressure-stored HFC-227ea combined distribution system with 6 sets of 150L cylinders configured for the maximum protected area. Equip independent selector valves for each area to realize targeted area fire suppression.

Implementation Effects

1. The system passed official fire inspection and acceptance, fully complying with GB50370-2005 and GB50263-2007 standards.

2. Stable long-term operation with real-time self-diagnosis function, zero fault alarms occurred.

3. Simulated fire tests completed full agent discharge within 8 seconds, reaching the 8% standard extinguishing concentration with no fire blind spots.

4. Zero residue and zero equipment damage after fire suppression, fully meeting the clean operation requirements of data centers.

Customer Evaluation: The system features professional design, standardized construction and reliable operation. It provides efficient and safe all-round fire protection for the data center without any impact on precision equipment, fully meeting the customized fire safety demands of large Internet data centers.

10.2 Case 2: Financial Disaster Recovery Center Project (Shenzhen)

Project Overview: The 1800㎡ disaster recovery center is divided into 4 protected areas, hosting core financial business servers and storage equipment, belonging to key manned financial infrastructure with strict requirements for both fire suppression and personnel safety.

Adopted Solution: Adopt KITOZER 15MPa high-pressure IG541 combined distribution system, equipped with 4 sets of 80L cylinders and 100% standby backup cylinders to ensure ultra-reliable operation.

Implementation Effects

1. The system passed fire acceptance, specially applicable to long-term manned key scenarios.

2. Intelligent multi-sensor detection realizes ultra-early fire warning, minimizing potential fire losses.

3. Simulated tests completed 95% agent discharge within 50 seconds, reaching 37.5% standard extinguishing concentration and 10-minute soaking time to completely eliminate fire re-ignition risks.

4. No toxic or harmful residues after discharge, allowing safe personnel entry and normal equipment operation without any damage.

Customer Evaluation: The IG541 system completely solves our concerns about personnel safety while ensuring excellent fire suppression performance. It features stable operation and convenient maintenance, serving as an ideal fire protection solution for manned financial core infrastructure.

10.3 Case 3: Old Bank Computer Room Renovation Project (Beijing)

Project Overview: The 800㎡ old computer room is divided into 3 protected areas, hosting core business servers and network equipment. The renovation required zero impact on existing business operation and improved fire system reliability.

Adopted Solution: Adopt KITOZER 4.2MPa HFC-227ea independent unit system, with independent fire suppression configuration for each protected area to avoid cross-impact during phased construction and renovation.

Implementation Effects

1. Phased construction realized zero interruption to existing equipment operation and business continuity during renovation.

2. The renovated system passed fire acceptance and fully meets national standard specifications.

3. Triple automatic/manual/emergency manual startup modes ensure reliable response under all emergencies.

4. Fire tests completed rapid discharge within 8 seconds with standard extinguishing concentration, causing no damage to existing precision equipment.

Customer Evaluation: KITOZER’s professional design and construction team perfectly solved the renovation difficulties of old computer rooms. The system features stable performance and low maintenance, providing reliable fire safety guarantee for the bank’s core business operation with zero impact on daily work.

11. SEO Keywords & Tags

11.1 Core Search Keywords

Computer room fire protection, piped gas fire suppression, KITOZER gas fire extinguishing system, HFC-227ea fire suppression system, IG541 mixed gas fire extinguishing system, data center fire protection, computer room gas fire suppression solution, combined distribution gas fire system, independent unit gas fire system, clean gas fire suppression system

11.2 SEO Long-tail Keywords

Computer room piped gas fire suppression solution, KITOZER brand gas fire extinguishing system, data center computer room fire protection system, HFC-227ea fire system design specification, IG541 system application cases, computer room fire system composition and classification, gas fire system bidding parameters, computer room fire system schematic diagram, gas fire system technical parameters, clean gas fire suppression advantages

11.3 Product Tags

#ComputerRoomFireProtection #PipedGasFireSuppression #KITOZER #HFC227ea #IG541 #DataCenterFireSafety #GasFireExtinguishingSystem #FireProtectionSolution #ComputerRoomSafety #CleanFireSuppressionSystem