Table of Contents
ToggleProduct Overview
The KITOZER 500 kW plate heat exchanger is a brazed-plate unit that hydraulically isolates the primary plant loop from the IT secondary loop in large data center CDUs. Stacked AISI 316 stainless plates are vacuum-brazed with copper to form a compact, pressure-tight heat transfer pack with no gaskets to replace. The unit provides reliable separation of building water quality from the clean secondary loop, while transferring heat at close approach temperatures of 1 to 2 C. It is delivered with pressure test certificates and mounting brackets, ready to bolt into the CDU skid or stand-alone piping. Brazed plate exchangers occupy a fraction of the footprint of shell-and-tube units at the same duty, which is valuable in space-constrained mechanical rooms.
Technical Specifications
Rated duty 500 kW at 10 K delta T, close approach 1.5 K. Plates AISI 316, 0.5 mm thick, copper brazed. Working pressure 1.6 MPa, test pressure 2.4 MPa. Design temperature minus 20 to 180 C. Connections DN100 PN16 flanged on both sides. Dimensions 800 x 300 x 700 mm. Weight 180 kg. Fouling factor 0.00001 m2K/W. Optional nickel-brazed version for deionized water. Certification CE, PED. Mounting brackets included. Connection orientation configurable horizontal or vertical.
Application Scenarios
This exchanger is used in central plant CDUs, row-level CDUs above 300 kW, immersion tank primary connections, and industrial process heating or cooling separation. It also suits district heating interfaces and solar thermal storage loops where primary and secondary must be isolated. Additional deployments include geothermal heat pump loops, refrigeration cascade systems, and marine engine jacket water heat recovery.
Advantages and Features
Brazed construction eliminates gasket replacement, a major maintenance saving over gasketed plate exchangers. Compact footprint delivers 500 kW in a cabinet smaller than a domestic washing machine. Close temperature approach enables high free-cooling utilization. Stainless 316 plates resist glycol corrosion. Copper brazing provides a permanent, leak-free joint for decades of service. Nickel-brazed option supports deionized water loops where copper ions are unacceptable.
Installation and Maintenance
Mount vertically with connections oriented as labeled, anchor with M12 bolts, and connect flanges with proper gaskets. Provide a small differential pressure gauge across the unit to track fouling. No routine maintenance is required; if pressure drop rises above 1.5 times clean value, isolate and chemically clean with a 5 percent citric acid solution. Inspect annually for external corrosion. Spare gaskets for the flanged connections are stocked at the service center. The unit can be cleaned in place without removing it from the skid.
Packaging and Warranty
Each exchanger is packed in a wooden crate with plastic end caps to keep debris out. Pressure test certificate and mounting template are included. KITOZER offers a 5 year warranty against manufacturing defects. Nickel-brazed versions and custom plate counts are available on request with a 3 week lead time. Spare gaskets and mounting brackets are stocked locally.
Price
From $4,800/pc. Contact +86 13922289957 for exchanger sizing and nickel-brazed options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com