KITOZER Point Photoelectric Smoke Detector

The KITOZER point photoelectric smoke detector uses a light scattering chamber to detect visible smoke particles from smoldering fires. An infrared LED pulses light across the chamber, and a photodiode positioned at an angle detects light scattered by smoke entering the chamber. When scattered light exceeds the threshold, the detector alarms. This design is particularly sensitive to the slow, smoldering fires that produce large quantities of visible smoke before flame development, making it ideal for offices, hotels, warehouses, and residential corridors.

Product Overview

The detector is a compact circular unit that mounts on a standard base wired to the fire alarm loop. A removable cover protects the optical chamber during construction. The unit includes a built-in LED that flashes normal status and latches on alarm, and a test button allows commissioning and functional checks. The detector is available in conventional 2-wire or addressable loop versions, with a remote LED indicator option for high ceilings.

Technical Specifications

Operating voltage is 12 to 24 volts DC. Standby current is less than 50 microamps. Alarm current is 20 to 50 milliamps. Sensitivity meets standard smoke detector spacing. Operating temperature is -10 to 60 degrees Celsius. Humidity range is up to 95 percent non-condensing. Mounting base is standard 6-inch. Weight is approximately 120 grams. Enclosure is white ABS plastic.

Application Scenarios

Point photoelectric detectors are installed in offices, hotel rooms, corridors, classrooms, retail stores, warehouses, apartments, and public buildings. They are preferred for spaces where smoldering fires are likely, such as upholstered furniture, bedding, and paper storage. They are not recommended for dusty, steamy, or smoky environments where false alarms would be frequent; in those settings, heat or multi-sensor detectors are more appropriate.

Advantages

Photoelectric sensing responds early to smoldering fires, giving occupants more evacuation time. The detector is low-cost, easy to install, and widely compatible with conventional and addressable panels. The removable cover allows chamber cleaning. Built-in test button simplifies commissioning. Low standby current extends battery life in wireless or loop-powered systems. The design is proven over decades of installation.

Installation and Maintenance

Mount detectors on the ceiling at the spacing specified by code, at least 300 millimeters from walls and light fixtures. Avoid dead air spaces near corners or ducts. After wiring, test each detector with aerosol smoke or a test wand. Inspect detectors annually, removing dust from the chamber with a soft brush or vacuum. Replace detectors every 10 years. Clean covers with a damp cloth only; do not use solvents.

Engineering Notes

Space detectors per code, at least 300mm from walls and lights. Avoid dead air spaces near ducts. Use a cover during construction to prevent dust contamination. Test with aerosol smoke after installation. Clean chambers annually. Replace every 10 years.

Code and Compliance

Detectors must comply with local smoke detector standards. Submit the detector layout for approval. Annual inspection includes functional testing of each device. Keep a detector schedule on the as-built drawing. Replace detectors that fault repeatedly.

Warranty and Accessories

From $45 per point photoelectric smoke detector. The detector carries a five-year warranty. KITOZER supplies conventional and addressable versions, plus remote LED indicators. Spare bases and covers are available. Contact +86 13922289957 for project quantities.

Detailed Application Examples

Twenty photoelectric smoke detectors cover a 500 square meter office floor, spaced per code. Each detector has a test button, and an LED flashes normal status. Aerosol smoke tests confirm operation after installation. Detectors are cleaned annually and replaced at 10 years.

Long-term Operational Benefits

Point smoke detectors are the lowest-cost detection device, with a service life of 10 years and no calibration required. Because they are standardized, replacement detectors from any brand fit the same base, simplifying spares. Low standby current means many detectors share one loop without overloading the panel. Annual inspection is quick, with a test button on each unit. The five-year warranty covers early failures.

System Integration

Point detectors wire onto a supervised loop or conventional zone, so a broken wire or missing detector faults the panel. The loop can carry many detectors while reporting each device individually in addressable versions. Remote LED indicators can be mounted outside the room so staff can see which detector alarmed without entering. Detectors also integrate with the fire panel for alarm verification and alarm routing.

Why Choose KITOZER

KITOZER smoke detectors are built for commercial fire duty and backed by a five-year warranty. Each detector is smoke-tested before shipment. KITOZER supplies matching bases, remote LEDs, and test wands as a complete package, simplifying procurement for contractors.

Summary

In summary, the point photoelectric smoke detector is a low-cost, reliable building block for any fire alarm system. Its proven optical chamber and wide compatibility make it suitable for general commercial spaces. KITOZER supplies the detector with a five-year warranty and supports project quantities with fast delivery.

Price

From $45 per point photoelectric smoke detector. Contact +86 13922289957 for project quantities and addressable versions.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com