The KITOZER positioning water leak detection cable is a sensitive linear sensing cable that detects liquid water along its entire length and reports the exact location of the leak to within one meter. It is designed for data centers, server rooms, chemical plants, industrial washing areas, and basement mechanical rooms where water leaks from pipes, cooling units, or condensation can cause expensive equipment damage. Unlike non-positioning leak cables that only alarm “water somewhere on the loop,” the KITOZER cable tells maintenance staff exactly which meter segment has water, cutting response time from hours to minutes.
The cable is constructed from four twisted, color-coded conductive wires wrapped in a semi-conductive polymer jacket. When water contacts the outer jacket, it creates a measurable electrical path between the sensing wires. The connected KITOZER leak controller measures this path and calculates distance using impedance. The cable is reusable: once the leak source is fixed and the cable is dried, it resets automatically without requiring replacement. This makes positioning leak detection far more cost-effective than disposable spot detectors that must be replaced after every event.
Table of Contents
ToggleProduct Overview
The cable is supplied in 30-meter standard lengths, with custom lengths up to 150 meters available. Each end terminates with a connector that plugs into the KITOZER leak controller, and intermediate segments can be joined using splice connectors. The cable is rated IP67 when installed, and its fluoropolymer jacket resists oil, coolant, and common industrial chemicals. A marker sleeve every meter allows physical correlation between the reported distance and the cable run.
Technical Specifications
Sensing cable type: four-wire semi-conductive polymer, positioning. Detection medium: water, coolant, and most conductive liquids. Location accuracy: plus or minus 1 meter. Standard length: 30 meters, extendable to 150 meters per controller zone. Cable diameter: 6.2 mm. Operating temperature: -40 to +60 C. Response time: less than 3 seconds. Reset method: automatic after drying. Jacket material: fluoropolymer, oil and coolant resistant. Connector: screw-lock M12. Controller interface: RS485 Modbus RTU plus relay output. Certifications: CE, RoHS. KITOZER warranty: 3 years, with free splice connectors included.
Application Scenarios
This cable is laid along raised floor pedestals in data centers, under CRAC unit drains, around UPS battery trays, along chiller pipes in mechanical rooms, inside cooling water channels in semiconductor plants, and around process piping in chemical facilities. In a typical data center deployment, the cable runs around the perimeter of each server row and loops under each CRAC unit. When a CRAC drain pan overflows, the controller reports “water at 14 meters” so the technician can immediately locate the affected CRAC unit without lifting floor tiles across the whole room.
Advantages and Features
The key advantage is precise location reporting combined with reusable sensing. Many facilities still use spot detectors that only cover a few points, leaving long stretches of pipe unprotected. The KITOZER continuous cable covers the entire perimeter and tells staff where to look. The fluoropolymer jacket survives coolant spills and cleaning chemicals, so the cable does not need replacement after a small leak. The Modbus interface integrates with KITOZER monitoring hosts and third-party BMS systems, allowing leak alarms to trigger camera snapshots, lighting, and automatic water shut-off valves.
Installation and Maintenance Advice
Secure the cable with adhesive clips every 50 cm, keeping it close to the floor surface where water naturally pools. Avoid running the cable through areas where foot traffic or rolling carts can damage it. Do not stretch the cable tightly; leave slack to allow thermal movement. Inspect the cable visually every 6 months for cuts, crushing, or chemical staining. Perform a leak test quarterly by placing a damp cloth on the cable at a known position and verifying that the controller reports the correct distance. Replace any section that shows jacket damage, as compromised insulation can cause false alarms.
Typical Deployment Configuration
In a data center hall, KITOZER positioning leak cable is laid around the perimeter of every server row, under each CRAC unit drain pan, and along chilled water pipes in the overhead corridor. Each 30-meter segment connects to a KITOZER leak controller that reports both alarm state and distance over Modbus to the central monitoring host. When a CRAC drain pan overflows, the controller reports water at a specific meter position, and the host displays the corresponding row and CRAC unit on the floor plan. The host also triggers a relay output that closes a motorized shutoff valve on the chilled water supply, limiting the spill while maintenance is dispatched. For large data centers, multiple controllers are networked on a single RS485 bus, covering thousands of square meters with one monitoring point. KITOZER provides installation clips, splice connectors, and termination resistors with every cable order, and offers a layout drawing service to help customers plan cable routing before installation.