Table of Contents
ToggleProduct Overview
KITOZER 96-loop power distribution monitor is a centralized metering and alarm device designed to track current, voltage, power, and breaker status across up to 96 outgoing feeders inside a low-voltage switchboard or data center power cabinet. The main unit hosts a color touchscreen and a backplane of measurement and digital-input modules, and it communicates with the building management system or DCIM over Modbus TCP. By replacing dozens of individual panel meters with one centralized monitor, the system reduces panel depth, cabling, and maintenance cost while giving operators a single view of every circuit in the cabinet. The monitor supports both solid-core and split-core current transformers, which simplifies retrofit into live panels without removing existing busbars.
Technical Specifications
Main unit 7 inch color touchscreen, up to 96 current measurement channels via plug-in CT modules, up to 96 digital input channels for breaker auxiliary contacts, three phase voltage measurement on main incomer, per-channel current range 1A to 600A depending on CT, accuracy class 0.5S. Active power, reactive power, power factor, kWh per channel. Modbus TCP, Modbus RTU, SNMP option. Alarm relay outputs 8 channels. Power supply 85V to 265VAC. Operating temperature minus 10C to plus 55C. DIN rail or panel mount. CE, KITOZER brand, three year warranty.
Application Scenarios
This monitor is installed in data center main switchboards, UPS output cabinets, busway tap-off boxes, and factory low-voltage distribution panels. It is also used in commercial building electrical rooms where energy cost allocation between tenants requires sub-metering on every feeder. The split-core CT option makes it suitable for retrofit projects where the panel is live and cannot be shut down for conventional solid-core CT installation. Facilities teams use the monitor to identify overloaded circuits, track energy use per department, and trigger alarms before a breaker trips.
Advantages and Features
Centralized metering replaces dozens of standalone meters, saving panel space and purchase cost. Plug-in modules allow channel count to grow from 12 to 96 without replacing the main unit. Split-core CTs reduce installation time in live panels. The touchscreen shows per-channel values, bar graphs, and historical trends, and the Modbus TCP gateway pushes data to BMS or DCIM. Alarm thresholds are programmable per channel, and event logs retain the last 1000 events with timestamp. The system also supports load-shedding logic, automatically reporting non-critical feeders when total load exceeds a configurable threshold.
Installation and Maintenance
Mount the main unit on the panel door or on a DIN rail inside the cabinet. Install current transformers around each outgoing cable, keeping polarity correct, and route CT secondary wires to the plug-in modules. Wire digital inputs to breaker auxiliary contacts. Set the CT ratio, alarm thresholds, and Modbus address through the touchscreen. Commission each channel by comparing measured current against a clamp meter. Maintenance is limited to annual calibration verification and visual inspection of CT terminations. Firmware updates are available via USB port.
Price
From $1,980/pc. Contact +86 13922289957 for 96-loop monitor pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com