The KITOZER power distribution surge protection module system is a multi-stage Surge Protective Device (SPD) solution designed for power supply and distribution networks. Its core functions include discharging lightning surges, suppressing switching overvoltages, and clamping residual voltage on circuits, so as to protect downstream precision power distribution equipment, servers, PLCs, inverters and terminal loads. It prevents equipment burnout, data loss and system shutdown risks caused by lightning strikes or power grid fluctuations.
Complying strictly with GB50057-2010 and GB/T 18802.1 standards, the system adopts a three-level protection architecture: Class I (T1) + Class II (T2) + Class III (T3). It realizes full-link layered current discharge and progressive voltage limiting from the main incoming line to terminal equipment, and is applicable to power distribution lightning protection scenarios including civil buildings, data centers, industrial plants, communication base stations and photovoltaic power stations.

Power Distribution Surge Protection Module
2. System Composition
The KITOZER power distribution surge protection module system consists of four major components: core surge protection units, auxiliary protection units, intelligent monitoring units, and earthing & equipotential bonding units. All components work in coordination to form a complete protection system.
2.1 Core Surge Protection Unit (SPD Modules)
- Class I Surge Protection Module (T1) Adopts Gas Discharge Tube (GDT) technology with 10/350μs waveform. Installed in main power distribution cabinets or at the front of transformers, it discharges high-energy direct lightning strikes with impulse current Iimp ≥ 12.5kA.
- Class II Surge Protection Module (T2) Adopts Metal Oxide Varistor (MOV) technology with 8/20μs waveform. Deployed on floor or sub-distribution boxes, it absorbs residual surges with nominal discharge current In ranging from 40kA to 60kA.
- Class III Surge Protection Module (T3) Combines TVS diode and RC filtering technology with 1.2/50μs waveform. Mounted at the front of terminal equipment (such as computer room PDUs and precision instrument power ports), it delivers precise voltage limiting with residual voltage Up ≤ 0.8kV.
2.2 Auxiliary Protection Unit
- Front circuit breakers / fuses: Special 1P/2P/3P/4P air switches connected in series at the front of each SPD level to provide short-circuit and overload protection, isolate failed SPDs, and avoid fire hazards caused by short-circuiting of aged SPDs.
- Decoupler (optional): Inductors or resistors connected in series between multi-stage SPDs to guarantee sequential coordination of each level, prevent premature actuation of downstream SPDs, and improve overall protection efficiency.
2.3 Intelligent Monitoring Unit

CAD Drawing of Surge Protection Distribution Box
- SPD status monitoring module: Real-time collection of SPD operating status, leakage current and failure alarms. Equipped with dry contact remote signaling output and RS485 communication interface, it can be connected to environmental monitoring systems for remote fault early warning.
- Lightning counter: Records the number of lightning strikes to facilitate lightning protection effect evaluation and maintenance cycle formulation.
2.4 Earthing & Equipotential Bonding Unit
- Dedicated lightning protection earthing wire: Multi-stranded copper cable with cross-sectional area ≥16mm², connected straight and short between SPD earthing terminals and earthing grid, with earthing resistance ≤4Ω.
- Equipotential bonding busbar: Reliably connects metal cabinet shells, SPD earthing terminals, PE lines and metal cable trays to eliminate potential differences and prevent counterattack of ground potential.
3. System Classification
3.1 Classification by Protection Level (Core Classification)
Class I Surge Protection System (T1/Class I)
- Installation Location: Main incoming cabinet of buildings, high-voltage power distribution rooms, low-voltage sides of transformers
- Core Parameters: Iimp ≥12.5kA (10/350μs), Uc: 420VAC, Up ≤2.5kV
- Function: Discharge direct lightning and high-energy induced lightning, protect main power distribution equipment
Class II Surge Protection System (T2/Class II)
- Installation Location: Floor distribution boxes, workshop sub-distribution boxes, UPS input terminals
- Core Parameters: In: 40-60kA (8/20μs), Uc: 385VAC, Up ≤1.5kV
- Function: Absorb residual surges from Class I SPDs, suppress switching overvoltages, protect sub-distribution equipment and UPS
Class III Surge Protection System (T3/Class III)
- Installation Location: Computer room distribution boxes, front of PDUs, power ports of precision equipment (servers, PLCs, medical devices)
- Core Parameters: In: 20-40kA (8/20μs), Uc: 385VAC, Up ≤0.8kV
- Function: Precise terminal voltage clamping to protect sensitive electronic equipment and limit residual voltage within the equipment withstand level
3.2 Classification by Power Distribution System Type

Laian Intelligent Production Workshop
- Single-phase surge protection system (220V): Provides L-N, L-PE and N-PE protection, applicable to residential buildings, office areas and small equipment
- Three-phase three-wire surge protection system (380V): Offers L1-L2, L2-L3, L3-L1, L1-PE, L2-PE, L3-PE protection for industrial motors and three-phase equipment
- Three-phase four-wire surge protection system (380/400V): Delivers full-mode protection including L1-N, L2-N, L3-N, L1-PE, L2-PE, L3-PE, N-PE. Most widely used in commercial buildings, data centers and large factories
3.3 Classification by Product Structure
- Modular surge protector: DIN rail mounting (35mm), pluggable design for easy replacement and maintenance, compatible with standard distribution boxes (mainstream type)
- Cabinet-type surge protector: Integrated cabinet design with built-in SPDs, circuit breakers and earthing busbars, IP54 protection rating, suitable for outdoor and harsh environments such as base stations and photovoltaic power stations
4. System Schematic Diagram
4.1 Typical Three-Phase Four-Wire Three-Level Surge Protection System Schematic
4.2 Working Principle Explanation

On-site Installation of Surge Protection Modules
- Normal Operating Condition: All levels of SPDs present high impedance (megohm level) without interfering with normal power supply of the distribution system, with leakage current ≤50μA.
- Surge Intrusion: When lightning strikes or switching overvoltage occurs, circuit voltage surges instantly to thousands of volts:
- Class I SPD (GDT): Breaks down and conducts first, discharging 70%-90% of high-energy surges and limiting residual voltage below 2.5kV.
- Class II SPD (MOV): Absorbs residual surges from Class I SPDs and further limits voltage below 1.5kV to protect sub-distribution equipment.
- Class III SPD (TVS): Performs precise terminal clamping to control residual voltage under 0.8kV for sensitive terminal equipment.
- After Surge Fades: SPDs automatically restore high impedance and the system resumes normal power supply. If an SPD ages and malfunctions, the front circuit breaker trips to isolate the faulty unit, and the monitoring module outputs an alarm signal simultaneously.
5. Complete System Configuration List (Basic / Standard / Premium, Brand: KITOZER)
5.1 Basic Version (Basic Protection, Civil / Small Office, Single-Phase 220V)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Class I Single-Phase Surge Module (T1) | KTR-S12.5 | Iimp:12.5kA (10/350μs); Uc:420VAC; Up≤2.5kV; Protection Modes: L-PE, N-PE; DIN rail mounting | 1 | Set | KITOZER | Main incoming cabinet |
| 2 | Class II Single-Phase Surge Module (T2) | KTR-S40 | In:40kA (8/20μs); Imax:80kA; Uc:385VAC; Up≤1.5kV; Protection Modes: L-N, L-PE, N-PE; DIN rail mounting | 1 | Set | KITOZER | Floor distribution box |
| 3 | Class III Single-Phase Surge Module (T3) | KTR-S20 | In:20kA (8/20μs); Imax:40kA; Uc:385VAC; Up≤0.8kV; Protection Modes: L-N, L-PE; DIN rail mounting | 1 | Set | KITOZER | Front of terminal equipment |
| 4 | Matching Circuit Breaker for Class I | KTR-B1P63 | 1P; Rated Current:63A; C-curve Trip; Short-circuit Breaking Capacity:6kA | 1 | Pc | KITOZER | Front of Class I SPD |
| 5 | Matching Circuit Breaker for Class II | KTR-B1P32 | 1P; Rated Current:32A; C-curve Trip; Short-circuit Breaking Capacity:6kA | 1 | Pc | KITOZER | Front of Class II SPD |
| 6 | Matching Circuit Breaker for Class III | KTR-B1P16 | 1P; Rated Current:16A; C-curve Trip; Short-circuit Breaking Capacity:6kA | 1 | Pc | KITOZER | Front of Class III SPD |
| 7 | Lightning Protection Earthing Busbar | KTR-G10 | Copper; Size:100×50×5mm; M6×4 Earthing Bolts | 1 | Pcs | KITOZER | Earthing inside distribution box |
| 8 | Dedicated Lightning Protection Cable | KTR-W16 | Multi-stranded copper cable; Cross-section:16mm²; Insulation Withstand Voltage:1kV | 5 | Meter | KITOZER | Connection between SPD and earthing busbar |
5.2 Standard Version (Standard Protection, Commercial / Small & Medium Industry, Three-Phase Four-Wire 380/400V)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Class I Three-Phase Four-Wire Surge Module (T1) | KTR-T12.5/4P | Iimp:12.5kA (10/350μs); Uc:420VAC; Up≤2.5kV; Protection Modes: L1-PE, L2-PE, L3-PE, N-PE; DIN rail mounting | 1 | Set | KITOZER | Main incoming cabinet |
| 2 | Class II Three-Phase Four-Wire Surge Module (T2) | KTR-T60/4P | In:60kA (8/20μs); Imax:120kA; Uc:385VAC; Up≤1.5kV; Full-mode protection; DIN rail mounting | 1 | Set | KITOZER | Sub-distribution box |
| 3 | Class III Three-Phase Four-Wire Surge Module (T3) | KTR-T40/4P | In:40kA (8/20μs); Imax:80kA; Uc:385VAC; Up≤0.8kV; Full-mode protection; DIN rail mounting | 1 | Set | KITOZER | Front of computer room / equipment |
| 4 | Matching Circuit Breaker for Class I | KTR-B4P63 | 4P; Rated Current:63A; C-curve Trip; Short-circuit Breaking Capacity:10kA | 1 | Pc | KITOZER | Front of Class I SPD |
| 5 | Matching Circuit Breaker for Class II | KTR-B4P32 | 4P; Rated Current:32A; C-curve Trip; Short-circuit Breaking Capacity:10kA | 1 | Pc | KITOZER | Front of Class II SPD |
| 6 | Matching Circuit Breaker for Class III | KTR-B4P16 | 4P; Rated Current:16A; C-curve Trip; Short-circuit Breaking Capacity:10kA | 1 | Pc | KITOZER | Front of Class III SPD |
| 7 | SPD Status Monitoring Module | KTR-MON | Monitors leakage current, operating status and failure alarms; Dry contact (NO/NC) & RS485 output; 24VDC power supply; DIN rail mounting | 1 | Set | KITOZER | Beside Class II SPD |
| 8 | Lightning Counter | KTR-CNT | Count Range:0-9999; Trigger Current:≥1kA; Passive power supply; DIN rail mounting | 1 | Set | KITOZER | Beside Class I SPD |
| 9 | Lightning Protection Earthing Busbar | KTR-G20 | Copper; Size:200×60×5mm; M8×4 Earthing Bolts | 1 | Pcs | KITOZER | Earthing inside distribution box |
| 10 | Dedicated Lightning Protection Cable | KTR-W25 | Multi-stranded copper cable; Cross-section:25mm²; Insulation Withstand Voltage:1kV | 8 | Meter | KITOZER | Connection between SPD and earthing busbar |
| 11 | Equipotential Bonding Strip | KTR-EB40 | Copper strip; Size:40×4mm; 1m per piece | 2 | Pcs | KITOZER | Connect cabinet and cable trays |
5.3 Premium Version (High-Grade Protection, Data Center / Large Industry / Outdoor, Three-Phase Four-Wire 380/400V with Intelligent Monitoring)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | High-Current Class I Three-Phase Four-Wire Surge Module (T1) | KTR-T25/4P | Iimp:25kA (10/350μs); Uc:420VAC; Up≤2.0kV; Full-mode protection; Plug-in with remote signaling; DIN rail mounting | 1 | Set | KITOZER | Main incoming cabinet / Transformer side |
| 2 | High-Discharge Class II Three-Phase Four-Wire Surge Module (T2) | KTR-T80/4P | In:80kA (8/20μs); Imax:160kA; Uc:420VAC; Up≤1.2kV; Full-mode protection; Plug-in with remote signaling; DIN rail mounting | 1 | Set | KITOZER | UPS input / Workshop power distribution |
| 3 | Low Residual Voltage Class III Three-Phase Four-Wire Surge Module (T3) | KTR-T60/4P | In:60kA (8/20μs); Imax:120kA; Uc:385VAC; Up≤0.6kV; Full-mode protection; Plug-in with remote signaling; DIN rail mounting | 1 | Set | KITOZER | Front of servers / precision equipment |
| 4 | High Breaking Capacity Circuit Breaker for Class I | KTR-B4P100 | 4P; Rated Current:100A; C-curve Trip; Short-circuit Breaking Capacity:20kA; Undervoltage trip equipped | 1 | Pc | KITOZER | Front of Class I SPD |
| 5 | High Breaking Capacity Circuit Breaker for Class II | KTR-B4P63 | 4P; Rated Current:63A; C-curve Trip; Short-circuit Breaking Capacity:20kA; Undervoltage trip equipped | 1 | Pc | KITOZER | Front of Class II SPD |
| 6 | High Breaking Capacity Circuit Breaker for Class III | KTR-B4P32 | 4P; Rated Current:32A; C-curve Trip; Short-circuit Breaking Capacity:20kA; Undervoltage trip equipped | 1 | Pc | KITOZER | Front of Class III SPD |
| 7 | Multi-Stage Decoupler | KTR-D50 | Decoupling Current:50A; Impedance:10μH; 50/60Hz; DIN rail mounting | 2 | Set | KITOZER | Between Class I-II and Class II-III |
| 8 | Intelligent SPD Monitoring Unit (With Communication) | KTR-SMART | Monitors leakage current, temperature, failure and lightning strike count; RS485 & Modbus-RTU; Audible & visual alarm + dry contact; 24VDC power supply; DIN rail mounting | 1 | Set | KITOZER | System central monitoring |
| 9 | Integrated Cabinet-Type Surge Protector (Outdoor Backup) | KTR-BOX80 | Built-in T2 80kA SPD + circuit breaker + earthing busbar; IP54 protection; Cold rolled steel cabinet; Size:400×300×150mm | 1 | Set | KITOZER | Outdoor / Base Station / PV Power Station |
| 10 | Thickened Lightning Protection Earthing Busbar | KTR-G30 | Pure copper; Size:300×80×6mm; M10×6 Earthing Bolts | 1 | Pcs | KITOZER | Main earthing |
| 11 | Thickened Dedicated Lightning Protection Cable | KTR-W35 | Multi-stranded copper cable; Cross-section:35mm²; 1kV insulation; Anti-aging | 10 | Meter | KITOZER | SPD to earthing grid |
| 12 | Wide Equipotential Bonding Strip | KTR-EB60 | Copper strip; Size:60×5mm; 1m per piece | 3 | Pcs | KITOZER | Connect cabinets, cable trays and equipment shells |
| 13 | Matching Earthing Resistance Tester | KTR-ET | Measuring Range:0-200Ω; Accuracy:±5%; 9V battery power supply; Portable | 1 | Set | KITOZER | Earthing acceptance & maintenance |
6. Full Product Technical Parameters
6.1 Class I Surge Protection Module (T1)

Structure Drawing of Surge Protection Module Assembly
- Models: KTR-S12.5 (Single-phase), KTR-T12.5/4P (Three-phase four-wire), KTR-T25/4P (High-current three-phase four-wire)
- Test Type: T1 (10/350μs)
- Impulse Current Iimp: 12.5kA / 25kA (Peak)
- Maximum Continuous Operating Voltage Uc: 420VAC (50/60Hz)
- Voltage Protection Level Up: ≤2.5kV (12.5kA), ≤2.0kV (25kA)
- Protection Modes: L-PE, N-PE (Single-phase); L1-PE, L2-PE, L3-PE, N-PE (Three-phase four-wire)
- Response Time: ≤100ns
- Leakage Current: ≤50μA under normal working conditions
- Installation: 35mm DIN rail mounting
- Housing Material: Flame-retardant ABS (UL94 V-0)
- Operating Temperature: -40℃ ~ +85℃
- Protection Rating: IP20
6.2 Class II Surge Protection Module (T2)
- Models: KTR-S40 (Single-phase), KTR-T60/4P (Three-phase four-wire), KTR-T80/4P (High-discharge three-phase four-wire)
- Test Type: T2 (8/20μs)
- Nominal Discharge Current In: 40kA / 60kA / 80kA (Peak)
- Maximum Discharge Current Imax: 80kA / 120kA / 160kA (Peak)
- Maximum Continuous Operating Voltage Uc: 385VAC / 420VAC (50/60Hz)
- Voltage Protection Level Up: ≤1.5kV (40/60kA), ≤1.2kV (80kA)
- Protection Modes: L-N, L-PE, N-PE (Single-phase); Full-mode (Three-phase four-wire)
- Response Time: ≤25ns
- Leakage Current: ≤30μA under normal working conditions
- Installation: 35mm DIN rail mounting
- Housing Material: Flame-retardant ABS (UL94 V-0)
- Operating Temperature: -40℃ ~ +85℃
- Protection Rating: IP20
6.3 Class III Surge Protection Module (T3)

Installation Effect of Surge Protection Module
- Models: KTR-S20 (Single-phase), KTR-T40/4P (Three-phase four-wire), KTR-T60/4P (Low residual voltage three-phase four-wire)
- Test Type: T3 (1.2/50μs)
- Nominal Discharge Current In: 20kA / 40kA / 60kA (Peak)
- Maximum Discharge Current Imax: 40kA / 80kA / 120kA (Peak)
- Maximum Continuous Operating Voltage Uc: 385VAC (50/60Hz)
- Voltage Protection Level Up: ≤0.8kV (20/40kA), ≤0.6kV (60kA)
- Protection Modes: L-N, L-PE (Single-phase); Full-mode (Three-phase four-wire)
- Response Time: ≤1ns
- Leakage Current: ≤20μA under normal working conditions
- Installation: 35mm DIN rail mounting
- Housing Material: Flame-retardant ABS (UL94 V-0)
- Operating Temperature: -40℃ ~ +85℃
- Protection Rating: IP20
6.4 Matching Circuit Breakers
- Models: KTR-B1P63/KTR-B4P63 (For Class I), KTR-B1P32/KTR-B4P32 (For Class II), KTR-B1P16/KTR-B4P16 (For Class III)
- Poles: 1P / 4P
- Rated Current: 16A / 32A / 63A / 100A
- Trip Characteristic: C-curve (5-10In instantaneous trip)
- Short-circuit Breaking Capacity: 6kA / 10kA / 20kA
- Rated Voltage: 400VAC (50/60Hz)
- Installation: 35mm DIN rail mounting
- Housing Material: Flame-retardant PA66
6.5 Intelligent Monitoring Unit

Lightning Protection Command Center Platform
- Models: KTR-MON (Basic), KTR-SMART (Intelligent)
- Monitored Parameters: Leakage current, operating temperature, SPD failure, lightning strike count, power supply status
- Communication Interface: RS485 (Modbus-RTU), Dry contact (NO/NC, Capacity: 250VAC/3A)
- Power Supply: 24VDC (±10%)
- Power Consumption: ≤5W
- Alarm Mode: Audible & visual alarm (Intelligent model), remote dry contact alarm
- Installation: 35mm DIN rail mounting
- Operating Temperature: -30℃ ~ +70℃
6.6 Integrated Cabinet-Type Surge Protector
- Model: KTR-BOX80
- Built-in Components: T2 80kA three-phase four-wire SPD + 4P63A circuit breaker + earthing busbar
- Rated Voltage: 400VAC (50/60Hz)
- Discharge Capacity: In:80kA, Imax:160kA
- Voltage Protection Level: ≤1.2kV
- Protection Rating: IP54 (Dustproof & Waterproof)
- Cabinet Material: Cold rolled steel with electrostatic spraying
- Size: 400×300×150mm
- Operating Temperature: -40℃ ~ +85℃
7. Full Product Application Scope

Lightning Protection Engineering Case 1
7.1 Application Scope of Class I Surge Protection Module (T1)
- Commercial & Civil Buildings: Main power distribution rooms / low-voltage transformer sides of high-rise office buildings, hotels, shopping malls and residential buildings
- Industrial Field: Main incoming cabinets of factories, main power distribution rooms of workshops, low-voltage sides of high-voltage power distribution rooms
- Infrastructure: Communication base stations, photovoltaic power stations, substations, railway power distribution systems
- Data Centers: Park main power distribution cabinets, front of UPS main switches
7.2 Application Scope of Class II Surge Protection Module (T2)
- Commercial & Civil Buildings: Floor distribution boxes, sub-distribution boxes of office areas, elevator power distribution
- Industrial Field: Workshop sub-distribution boxes, power supply terminals of inverters / PLC control cabinets, motor power distribution
- Data Centers: UPS output terminals of computer rooms, front of column cabinets, precision air conditioning power distribution
- Infrastructure: Distribution boxes of base station computer rooms, AC output terminals of photovoltaic inverters
7.3 Application Scope of Class III Surge Protection Module (T3)

Lightning Protection Engineering Case 2
- Circuit breakers: Installed at the front of each SPD level for short-circuit, overload and fault isolation protection
- Monitoring units: Deployed in computer rooms, data centers and industrial sites to remotely monitor SPD status and send fault alarms
- Cabinet-type surge protectors: Used outdoors and harsh environments (high temperature, humidity, dust), applicable to base stations, photovoltaic power stations and field equipment
- Earthing & equipotential bonding products: Required for all lightning protection systems to build low-impedance discharge paths and eliminate potential differences
8. Full Product Advantages
8.1 Core Functional Features
- Multi-stage protection for full-link coverage: T1+T2+T3 three-level architecture realizes progressive surge discharge and precise voltage limiting, covering the entire link from main incoming lines to terminal equipment without protection blind spots.
- High discharge capacity & low residual voltage: Class I maximum 25kA (10/350μs), Class II maximum 80kA, Class III residual voltage as low as 0.6kV, exceeding national standards for superior protection performance.
- Ultra-fast response: Class III response time ≤1ns, nanosecond-level actuation to instantly suppress surges and protect sensitive equipment.
- Plug-in design for easy maintenance: Hot-swappable SPD modules allow replacement without power cut, reducing maintenance costs and downtime risks.
- Flame-retardant & explosion-proof for high safety: UL94 V-0 flame-retardant ABS housing with built-in overheat protection to prevent fire hazards caused by short-circuit of aged SPDs.
- Wide temperature range for multi-environment adaptation: Stable operation from -40℃ to +85℃ under high temperature, low temperature and humid harsh conditions.
- Intelligent monitoring & remote management: Optional intelligent monitoring modules track leakage current, temperature and failure status in real time with RS485 communication for connection to environmental monitoring systems and unattended remote early warning.
8.2 Customization Advantages
- Custom voltage grades: Non-standard voltage grades such as 24V, 48V, 110V and 690V can be customized according to customer demands
- Custom discharge capacity: Discharge capacity ranging from 10kA to 200kA is customizable to match scenarios with different lightning intensity
- Custom protection modes: Single-phase, three-phase three-wire, three-phase four-wire, DC and other protection modes are available
- Custom structure & interfaces: DIN rail, cabinet-type and wall-mounted structures can be customized, together with dry contact, RS485, Ethernet and other interfaces
- Custom communication protocols: Modbus-RTU, Modbus-TCP, SNMP and other protocols are supported to match customers’ existing monitoring systems
8.3 Supply Chain & Service Advantages
- OEM/ODM processing support: Private labeling, customized R&D and mass production to help customers build proprietary brands
- Strict confidentiality agreements: Sign confidentiality contracts to protect customers’ customized schemes, technical parameters and project information from leakage
- Spot inventory & fast delivery: Core models in permanent stock; standard orders delivered within 3-7 days, urgent orders available for expedited processing to shorten project cycles
- Full-series product coverage: Complete lightning protection product lineup from Class I to III, single-phase to three-phase, standard to intelligent, indoor to outdoor, enabling one-stop procurement and lower purchasing costs
9. Bid Winning Technical Parameters for All Products (Marked with ★)
9.1 Bid Winning Parameters for Class I Surge Protection Module (T1)
- ★Test Type: T1 (10/350μs), complying with GB/T 18802.1 standard
- ★Impulse Current Iimp: ≥12.5kA (Peak), high-current model ≥25kA
- ★Maximum Continuous Operating Voltage Uc: ≥420VAC (50/60Hz)
- ★Voltage Protection Level Up: ≤2.5kV (12.5kA), high-current model ≤2.0kV
- ★Protection Modes: Support L-PE, N-PE (Single-phase); L1-PE, L2-PE, L3-PE, N-PE (Three-phase four-wire)
- ★Response Time: ≤100ns
- ★Housing Material: Flame-retardant ABS, UL94 V-0 grade with explosion-proof design
9.2 Bid Winning Parameters for Class II Surge Protection Module (T2)
- ★Test Type: T2 (8/20μs), complying with GB/T 18802.1 standard
- ★Nominal Discharge Current In: ≥40kA (Peak), high-discharge model ≥80kA
- ★Maximum Discharge Current Imax: ≥80kA (Peak), high-discharge model ≥160kA
- ★Maximum Continuous Operating Voltage Uc: ≥385VAC (50/60Hz)
- ★Voltage Protection Level Up: ≤1.5kV (40/60kA), high-discharge model ≤1.2kV
- ★Response Time: ≤25ns
- ★Plug-in design: Support hot swapping without power cut during replacement
9.3 Bid Winning Parameters for Class III Surge Protection Module (T3)
- ★Test Type: T3 (1.2/50μs), complying with GB/T 18802.1 standard
- ★Nominal Discharge Current In: ≥20kA (Peak), low residual voltage model ≥60kA
- ★Maximum Discharge Current Imax: ≥40kA (Peak), low residual voltage model ≥120kA
- ★Maximum Continuous Operating Voltage Uc: ≥385VAC (50/60Hz)
- ★Voltage Protection Level Up: ≤0.8kV (20/40kA), low residual voltage model ≤0.6kV
- ★Response Time: ≤1ns
9.4 Bid Winning Parameters for Intelligent Monitoring Unit
- ★Monitored Parameters: Support monitoring of leakage current, temperature, SPD failure and lightning strike count
- ★Communication Interface: Standard RS485 with Modbus-RTU protocol
- ★Alarm Output: Dry contact (NO/NC) with capacity ≥250VAC/3A
- ★Power Supply Voltage: 24VDC (±10%) with wide voltage adaptation
9.5 Bid Winning Parameters for Integrated Cabinet-Type Surge Protector
- ★Built-in Configuration: T2 80kA three-phase four-wire SPD + 4P63A circuit breaker + earthing busbar
- ★Protection Rating: IP54, dustproof and waterproof for outdoor harsh environments
- ★Discharge Capacity: In≥80kA, Imax≥160kA
- ★Voltage Protection Level: ≤1.2kV
10. Full Product Solution Portfolio
10.1 Civil Building Power Distribution Lightning Protection Solution (Basic Version, Single-Phase 220V)
- Scenario: High-rise residential buildings, small office buildings, shopping mall office areas with moderate lightning intensity and limited budget
- Architecture: T1 (Main incoming line) + T2 (Floor) + T3 (Terminal) three-level protection
- Configuration: Basic version list configuration, single-phase SPD + matching circuit breakers + basic earthing
- Effect: Effectively discharge induced lightning, protect household and office equipment with residual voltage ≤0.8kV, meeting national standard acceptance requirements
10.2 Commercial Building / Small & Medium Industrial Lightning Protection Solution (Standard Version, Three-Phase Four-Wire 380/400V)
- Scenario: Medium-sized office buildings, hotels, shopping malls and small & medium factories with high lightning intensity, requiring protection for UPS and precision equipment
- Architecture: T1 (Main incoming line) + T2 (Sub-distribution) + T3 (Front of equipment) three-level protection + intelligent monitoring
- Configuration: Standard version list configuration, three-phase four-wire SPD + high breaking capacity circuit breakers + SPD monitoring + lightning counter + standard earthing
- Effect: Discharge direct lightning and high-energy induced lightning with residual voltage ≤0.8kV, real-time monitoring of SPD status and remote alarms to guarantee stable operation of UPS and production equipment
10.3 Data Center / Large Industry / Outdoor Lightning Protection Solution (Premium Version, Three-Phase Four-Wire 380/400V)
- Scenario: Large data centers, cloud computing computer rooms, large factories, communication base stations and photovoltaic power stations with high lightning intensity, high-value core equipment and 7×24-hour stable operation requirements
- Architecture: High-current T1 + high-discharge T2 + low residual voltage T3 three-level protection + decouplers + intelligent monitoring + outdoor backup cabinet-type surge protector
- Configuration: Premium version list configuration, high-current three-phase SPD + high breaking capacity circuit breakers + decouplers + intelligent monitoring + cabinet-type surge protector + thickened earthing & equipotential bonding
- Effect: Withstand severe lightning surges with residual voltage ≤0.6kV, accurate sequential coordination of multi-level stages, intelligent early warning of faults, IP54 outdoor protection rating to achieve zero downtime of core equipment
10.4 Outdoor / Harsh Environment Lightning Protection Solution (Integrated Cabinet-Type)
- Scenario: Communication base stations, photovoltaic power stations, field equipment and highway electromechanical equipment exposed to high temperature, humidity, dust and frequent lightning strikes
- Architecture: Two-level protection combining cabinet-type integrated surge protector (T2) + terminal T3, outdoor installation with IP54 protection rating
- Configuration: KTR-BOX80 cabinet-type surge protector + T3 modules + dedicated earthing
- Effect: Dustproof and waterproof for harsh outdoor environments, large discharge capacity and low residual voltage, easy installation and maintenance to ensure long-term stable operation of outdoor equipment
11. Full Product Application Cases
11.1 High-Rise Residential Project in Guangzhou (Basic Version)
- Project Overview: 32-floor high-rise residential building with total construction area of 80,000㎡, single-phase 220V power distribution system and moderate lightning intensity
- Solution: Adopt KITOZER basic single-phase three-level lightning protection scheme. Install T1 12.5kA modules in main power distribution rooms, T2 40kA modules in floor distribution boxes and T3 20kA modules at each household inlet, equipped with matching circuit breakers and basic earthing
- Application Effect: Put into operation for 2 years, no equipment damage or tripping accidents during multiple thunderstorms, SPDs operate normally to effectively protect air conditioners, refrigerators, televisions, computers and other household equipment, and passed local lightning protection acceptance
11.2 Medium-Sized Factory Project in Shenzhen (Standard Version)
- Project Overview: Electronic processing plant with construction area of 50,000㎡, three-phase four-wire 380/400V power distribution system, equipped with PLCs, inverters and precision instruments, high lightning intensity
- Solution: Adopt KITOZER standard three-phase three-level lightning protection scheme. Install T1 12.5kA three-phase modules in main incoming cabinets, T2 60kA modules in workshop sub-distribution boxes and T3 40kA modules at the front of PLCs/inverters, equipped with high breaking capacity circuit breakers, SPD monitoring modules, lightning counters and standard earthing
- Application Effect: Operated for 3 years, successfully resisted multiple severe lightning strikes without equipment burnout or production shutdown. The monitoring module sent multiple early warnings of SPD aging for timely replacement, ensuring continuous production and reducing maintenance costs
11.3 Large Data Center Project in Dongguan (Premium Version)
- Project Overview: Large cloud computing data center with over 2,000 cabinets, three-phase four-wire 380/400V power distribution system, core equipment including servers, switches and storage devices requiring 7×24-hour operation, high lightning intensity
- Solution: Adopt KITOZER premium three-phase three-level lightning protection scheme. Install T1 25kA high-current modules in park main power distribution cabinets, T2 80kA high-discharge modules at UPS input terminals and T3 60kA low residual voltage modules at the front of server cabinet PDUs, equipped with decouplers, intelligent monitoring units, outdoor cabinet-type surge protectors and thickened earthing & equipotential bonding systems
- Application Effect: 5 years of operation with zero lightning strike accidents, zero equipment damage and zero downtime. The intelligent monitoring system sends real-time early warnings of SPD faults for remote maintenance, guaranteeing high availability of the data center and becoming an industry benchmark case
11.4 50MW Photovoltaic Power Station Project in Guangdong (Integrated Cabinet-Type)
- Project Overview: 50MW photovoltaic power station located outdoors with high temperature, humidity and frequent lightning strikes, requiring lightning protection for inverters and combiner boxes
- Solution: Deploy KTR-BOX80 cabinet-type integrated surge protectors at AC output terminals of inverters, matched with T3 40kA modules and dedicated earthing
- Application Effect: Operated for 4 years with IP54 protection rating adapting to harsh outdoor environments, resisting multiple severe lightning strikes without inverter damage and stable power generation, easy maintenance to reduce operation and maintenance costs
12. Product Common Faults & Maintenance
12.1 Common Faults & Troubleshooting Methods
- SPD Failure (Alarm Light On / Monitoring Module Triggered Alarm)
- Causes: Excessive lightning strikes, aging, overheating, excessive leakage current
- Handling: Replace with the same model SPD after power cut, inspect whether front circuit breakers work normally and earthing connection is reliable
- Frequent Tripping of Front Circuit Breakers
- Causes: Short-circuit of aged SPD, frequent surges, undersized circuit breaker rating
- Handling: Check damaged SPDs and replace faulty modules; replace circuit breakers with higher rated current; inspect earthing reliability
- Excessive Leakage Current (Monitoring Module Displays Over-Limit Leakage Current)
- Causes: SPD aging, dampness, surface contamination
- Handling: Clean and dry SPD surface; replace modules with severe aging
- No Surge Protection Effect (Equipment Still Damaged by Lightning Strikes)
- Causes: Incorrect SPD model selection, improper installation position, poor earthing, incomplete protection modes
- Handling: Recalculate surge current and replace matching models; adjust installation position close to protected equipment; test earthing resistance (≤4Ω); supplement missing protection modes
- No Communication of Monitoring Module
- Causes: Misconnected communication wires, incorrect baud rate / address setting, abnormal power supply
- Handling: Check RS485 wiring (correct A/B line connection); verify baud rate (9600bps) and address; test 24VDC power supply
12.2 Maintenance Cycle & Contents
Monthly Routine Inspection
- Check SPD appearance: No damage, deformation or burnt odor
- Observe status indicator lights: Green for normal operation, red for failure
- Inspect circuit breakers: Closed without tripping or overheating
- Check monitoring modules: Normal leakage current, temperature and lightning strike count without alarms
- Verify earthing connections: No looseness or corrosion, reliable connection
Quarterly Maintenance (Every 3 Months)
- Clean SPDs and distribution boxes: Remove dust and moisture to keep dry and clean
- Tighten wiring terminals: No loose wiring on SPDs, circuit breakers and earthing busbars
- Test earthing resistance: Must be ≤4Ω, rectify earthing system if exceeding standard
- Test SPD functions: Use professional instruments to test discharge capacity, residual voltage and response time to confirm normal parameters
Annual Overhaul (Once a Year Before Thunderstorm Season)
- Comprehensive testing of all SPDs: Aging test, leakage current test and residual voltage test; replace all unqualified units
- Calibrate monitoring modules: Verify communication, alarm and data collection functions, calibrate parameters
- Inspect circuit breakers: Aging test and short-circuit breaking capacity test, replace unqualified products
- Full inspection of earthing & equipotential bonding: Test earthing resistance, connection reliability and corrosion status, completely rectify hidden dangers
- Record maintenance data: Establish files to track SPD service life, lightning strike count and maintenance history
Service Life Management
- SPD design service life: 5-8 years under normal operating conditions, shortened to 3-5 years in lightning-prone environments
- Mandatory replacement upon reaching service life or lightning strike count ≥20 times to avoid failure risks
13. Factory Strength & After-Sales Service
13.1 Factory Strength
- Brand Guarantee: KITOZER (Laian Intelligent) has 15 years of focus on power distribution lightning protection and environmental monitoring, a national high-tech enterprise with multiple lightning protection patents and well-known brand status in the industry
- Production Scale: Modern production base in Guangzhou covering 10,000㎡ with fully automatic production lines and annual output of 500,000 lightning protection modules to meet mass order demands
- R&D Capacity: Professional R&D team of over 20 engineers independently develops core SPD technologies including GDT, MOV and TVS composite protection, iterating products continuously and launching 3-5 new models annually
- Quality Control: Full-process quality inspection including raw material procurement (imported chips and high-quality components), production (SMT patch, wave soldering, aging test) and finished product testing (discharge, residual voltage, response time, high-low temperature test). 100% factory inspection, certified with ISO9001, CE and RoHS
- Supply Chain Advantages: Strategic cooperation for core components to reduce costs via bulk procurement; permanent spot inventory, standard models delivered within 3 days, customized models within 7-15 days
13.2 After-Sales Service
- Warranty Commitment: 5-year warranty for all products (excluding man-made damage and over-spec lightning strikes), free repair and component replacement within warranty period
- Technical Support: 7×24-hour technical hotline, professional engineers providing model selection consultation, scheme design, installation guidance and fault troubleshooting; remote online technical support for rapid problem resolution
- Installation & Commissioning: Free supply of installation drawings and technical disclosure; engineers can be dispatched to large projects for on-site installation guidance, commissioning and training to ensure normal system operation
- Customization Service: Free customized schemes, technical parameters and appearance structures to meet personalized customer demands; sign confidentiality agreements to protect customer intellectual property
- Maintenance Service: Annual maintenance contracts available for regular inspection, maintenance and calibration to extend product service life; emergency fault response within 24 hours and on-site arrival within 48 hours for Guangdong region
- Training Service: Free training for customers on product principles, installation, maintenance and fault handling to improve independent maintenance capacity
14. Conclusion
The KITOZER power distribution surge protection module system features multi-stage protection architecture, high-reliability performance, intelligent monitoring management and customized services. Designed in strict compliance with national standards, it adapts to power distribution lightning protection scenarios covering civil, commercial, industrial, data center and outdoor fields.
By progressively discharging surges, accurately clamping residual voltage and intelligently pre-warning faults, the system effectively protects power distribution equipment and terminal loads, reduces lightning strike losses and operation & maintenance costs, and guarantees stable system operation.
With 15 years of industry experience, strong R&D capacity, strict quality control and comprehensive after-sales service, KITOZER has become a preferred brand in the power distribution lightning protection sector. Its products are widely applied in key projects nationwide and win consistent customer recognition. In the future, KITOZER will continue technological innovation, optimize product performance and upgrade service quality to provide safer, more reliable and smarter power distribution lightning protection solutions for customers, and support the digital and intelligent safety upgrading of all industries.
15. SEO & Tags
15.1 Core Keyword System
- Core Primary Keywords: Power distribution surge protection module, Power Surge Protector SPD, Three-phase power surge protector, KITOZER surge protection module
- High Conversion Long-Tail Keywords: Data center power distribution lightning protection scheme, Industrial plant power surge protector, Outdoor photovoltaic surge protection module, Precision equipment surge protection, Three-level power distribution lightning protection system
- Industry Traffic Keywords: Surge protector model selection, Power distribution system lightning protection design, Surge protection module technical parameters, SPD intelligent monitoring, Lightning protection solution cases
- Brand Exclusive Keywords: KITOZER power distribution lightning protection, Laian Intelligent SPD, KITOZER surge protector, KITOZER three-level lightning protection
- Drop-Down / Related Search Keywords: Power distribution surge protection module price, Top surge protection module brands, SPD installation method, Surge protector maintenance, Outdoor surge protector manufacturer
15.2 SEO Optimization Tag System
- Core Page Optimization Tag: Power Distribution Surge Protection Module Solution, KITOZER Three-Level Power Surge Protector SPD, Industrial & Data Center Lightning Protection System
- Title Tag: KITOZER Power Distribution Surge Protection Module Solution | Three-Level Power Surge Protector SPD | Industrial & Data Center Lightning Protection System
- Meta Keywords: Power distribution surge protection module, Power Surge Protector SPD, Three-phase surge protector, KITOZER lightning protection, Three-level lightning protection system, Industrial lightning protection, Data center lightning protection
- Meta Description: KITOZER provides professional power distribution surge protection module solutions with three-level protection architecture, high discharge capacity & low residual voltage, and intelligent monitoring. Suitable for industrial, data center and outdoor scenarios, 5-year warranty and customized services available.
- H1 Tag: KITOZER Power Distribution Surge Protection Module Solution
- H2 Tags: System Overview, System Composition, System Classification, System Schematic Diagram, Configuration List, Technical Parameters, Application Scope, Product Advantages, Bid Winning Parameters, Solution Portfolio, Application Cases, Product Faults & Maintenance, Factory Strength & After-Sales Service, Conclusion
- Internal Link Anchor Text Tags
- Core Anchor Texts: Power distribution surge protection module, KITOZER surge protector, Three-level lightning protection system
- Long-Tail Anchor Texts: Data center lightning protection scheme, Industrial power surge protector, SPD intelligent monitoring module
- Related Anchor Texts: Environmental monitoring system, Computer room power distribution solution, Precision equipment protection