ToggleProduct Overview
The KITOZER 30A 440V three phase power EMI filter is engineered for industrial three phase distribution panels, variable frequency drive cabinets, UPS input feeds, and motor control centers where conducted noise must be held within statutory emission limits. The filter combines three phase common mode chokes with a neutral conductor suppression path and a Y capacitor network, attenuating both line to line and line to earth interference generated by fast switching power semiconductors. With a 30A continuous rating and 440V insulation class, it is suited to the balanced three phase loads found in manufacturing plants, water treatment facilities, and building mechanical systems.
Modern motor drives and active front ends switch at kilohertz frequencies, injecting high frequency noise that propagates onto the plant supply and disturbs adjacent instrumentation. The KITOZER filter sits at the drive or UPS input and presents a low-impedance shunt to earth for that noise, while passing the fundamental 50 or 60 hertz power to the load. The neutral path is filtered as well, so unbalanced loads and single phase control circuits on the same panel do not bypass the suppression network. This makes the filter effective for both balanced motor loads and the mixed single and three phase loads typical of a real cabinet.
Technical Specifications
Rated voltage 440V three phase plus neutral and earth, rated current 30A at 50 to 60 Hz. Insertion attenuation reaches 100 dB common mode and 70 dB differential mode from 150 kHz to 30 MHz. Leakage current below 3.5 mA. Operating temperature minus 25 to plus 85 degrees Celsius. Enclosure is shielded steel chassis with screw terminals, optional IP20 protective cover. Safety ratings cover CE and IEC 60939. Mounting is panel or DIN rail, with bus bar connections for high current continuity.
The internal common mode chokes are wound on matched toroidal cores so that the three phases present equal impedance, which keeps the network effective even when the load is unbalanced. X2 line to line capacitors and Y line to earth capacitors are rated for safety class. A bleeder resistor discharges the capacitors within one minute of disconnect, in line with service safety. Terminal lugs accept up to 10 square millimeter cable, and a separate earth stud bonds the shielded housing to the cabinet ground.
Applications
Typical uses include input filtering for variable frequency drives, servo amplifier cabinets, medical isolation rooms, industrial computing racks, and renewable energy inverters. System designers place this filter directly after the main disconnect to prevent high frequency noise from the drive radiating onto the plant supply and disturbing PLC instrumentation, weighing scales, and communication cables. It also protects downstream sensitive control circuits from conducted noise coming from welding equipment, contactors, and capacitor switched power factor correction banks.
In a water treatment plant it quiets the supply feeding pump drives so that level transmitters and chemical dosing controllers read steadily. In a building mechanical room it prevents elevator drive noise from interfering with the BMS network. In a renewable energy station it helps the inverter meet grid emission codes. Where multiple drives share a bus, filters on each drive localize the noise at source rather than relying on a single central filter, which is the recommended engineering practice.
Advantages and Features
The three phase construction uses matched toroidal cores on all conductors to ensure balanced common mode rejection under load unbalance. The steel housing is electrically continuous across all mounting feet, providing a low impedance shield to the cabinet wall. Low leakage variant options are available for isolated IT systems. The terminal blocks accept lug connectors for robust field wiring, and the internal X2 and Y capacitors are certified to safety standards with proven self-healing behavior. A built-in discharge resistor ensures the capacitors are safe to touch within one minute of disconnection.
The housing is dimensioned to fit standard industrial panel cutouts, and the bus bar connection avoids the contact resistance build-up that plagues screw terminals on high-current paths. The filter is rated for continuous 30A duty with modest heating, so it can sit alongside heat-generating drives without extra cooling. Spare knockouts allow add-on components such as surge protective devices to be mounted on the same plate without additional cutouts.
Installation and Maintenance
Install the filter on a flat unpainted metal panel and torque the mounting bolts evenly for full grounding. Route the incoming supply on one side and the filtered outgoing cables on the opposite side, keeping them separated to avoid capacitive recoupling. Do not run signal wires in the same cable tray as the filtered three phase conductors. During commissioning, verify the earth continuity resistance below 0.1 ohm and record the leakage current under load.
Maintain by checking terminal torque annually and inspecting the enclosure for corrosion. Re-torque lugs after the first year because copper creep can loosen connections. If a drive fails EMC retest after years of service, suspect degraded capacitors before blaming the filter; the sealed internal parts otherwise require no routine service. When replacing, match the rated voltage and current and confirm the leakage current stays within the installation IT system limits.
Price
From $96 per piece. Contact plus 86 13922289957 for quotation and lead time. Low leakage variants available on request.