KITOZER
KITOZER

KITOZER Power EMI Filter: 6A 250V Single Phase

Product Overview

The KITOZER 6A 250V single phase power EMI filter is a compact line-conditioning module designed to suppress conducted electromagnetic interference on the alternating current supply of sensitive electronic equipment. By combining differential mode and common mode inductors with high-grade X2 and Y safety capacitors, the filter blocks both noise traveling along the live and neutral conductors and noise coupling between the power line and protective earth. This two-stage topology delivers high insertion attenuation across the interference band from 150 kHz to 30 MHz, helping rack-mounted servers, network switches, test instruments, medical devices, and industrial control cabinets meet EMC emission and immunity requirements.

Installed between the utility inlet and the internal power supply, the filter acts as the first barrier against conducted noise entering or leaving the equipment. Its low leakage current construction and reinforced insulation make it suitable for information technology and light industrial environments where safety class apparatus must comply with the limits of CISPR 32 and EN 55032. The 6A rating comfortably supports small workstation power supplies, edge routers, and desktop medical monitors while retaining margin for inrush current during cold start. Because conducted disturbances are the leading cause of certification failures and field complaints, placing a properly sized filter at the mains inlet reduces both certification cost and returned-unit risk.

The module is built around a shielded metal housing that provides a continuous low-impedance bond to the chassis. This housing is not merely mechanical protection; it prevents the filter itself from radiating the noise it has shunted to earth. Input and output compartments are physically separated inside the case to keep filtered and unfiltered wiring apart, which preserves the rated attenuation instead of letting noise couple across the enclosure. The result is a drop-in component that equipment builders specify as a standard line item on every mains-powered design.

Technical Specifications

Rated voltage 250V alternating current, rated current 6A at 50 to 60 Hz, single phase with live, neutral, and protective earth. Insertion attenuation reaches 120 dB common mode and 80 dB differential mode over the conducted band. Leakage current is below 0.5 mA at 250V, which suits devices that touch operators or patients. Operating temperature ranges from minus 25 to plus 85 degrees Celsius, with derating above 60 degrees. The enclosure uses a metal shielded housing with quick-connect terminals and a protective ground bond. Safety approvals cover CE, UL recognized components, and IEC 60939 passive filter classification. Mounting is chassis or DIN rail with screw terminals for secure field wiring.

Internal components are selected for long service life. The X2 capacitors are metalized polypropylene with self-healing behavior, and the Y capacitors carry safety certification to prevent failure modes that could break the protective earth. The common mode inductor uses a high permeability toroidal core that maintains impedance up to the rated current without saturation. Terminal wire range accepts 0.5 to 2.5 square millimeter conductors, and a transparent plastic terminal cover is included for servicing safety.

Applications

This filter is applied in small data center edge nodes, broadcasting and audio equipment, laboratory measurement instruments, household and professional medical devices, and industrial sensor controllers. It is equally effective when the goal is to stop switching power supply harmonics from polluting the supply and to prevent grid-borne surges and radio frequency noise from disrupting sensitive analog circuits. Equipment builders use it as a standard internal module to achieve compliance at first certification, while system integrators add it as a retrofit on legacy machinery that fails site EMC surveys.

A typical integration sits after the mains switch and before the internal fuse or power supply module. For medical carts and patient monitors the low leakage variant is chosen so that touch-current limits are respected. For audio and broadcast gear the filter removes the buzz and hum injected by nearby dimmers and variable speed fans. For factory sensor networks it quiets the supply so that 4 to 20 milliamp transmitters read stable values instead of drifting with the switching rhythm of adjacent drives.

Advantages and Features

The KITOZER power EMI filter uses high permeability nanocrystalline cores for stable attenuation under load current, rather than cheaper ferrite cores that saturate easily. The metal housing provides 360 degree shielding continuity to the chassis, avoiding the leakage paths common in plastic enclosed modules. Components are rated for safety class with internal fusing and X2 capacitors that self-heal after dielectric breakdown. The compact footprint allows dense layout inside 1U and 2U enclosures, and the terminal layout supports both top and bottom wiring for assembly flexibility.

Engineers value the predictable performance because the attenuation curves are published per unit rather than estimated. The through-hole and quick-connect options suit both automated board build and hand wiring. Because the filter is sealed, it resists the dust and oil found in industrial rooms, and the tin-plated terminals resist corrosion. The part numbering is consistent across volumes, so a design locked in prototype remains available at production quantities without redesign.

Installation and Maintenance

Mount the filter as close as possible to the alternating current inlet and bond its chassis firmly to a clean, unpainted metal surface to guarantee the shielding reference. Keep input and output wiring separated by at least 50 mm and avoid parallel routing, otherwise filtered noise will couple back across the enclosure. Use the supplied ground stud with a star washer and torque it to the recommended value for low impedance earth continuity. Maintain the protective earth bond with a resistance meter during commissioning and record the reading for the acceptance file.

Maintenance consists of an annual visual inspection of terminals and a resistance check of the protective earth bond. Tighten any loose screw and clean corroded contacts with contact cleaner. No internal servicing is required; if attenuation drifts or the device fails EMC retest, replace the whole module rather than opening the sealed enclosure, because opening compromises the shielded housing and the safety ratings. When replacing, use the same or higher rated part and verify the leakage current meets the application safety class.

Price

From $18 per piece. Contact plus 86 13922289957 for volume pricing and factory lead time. Bulk orders of five hundred pieces and above carry a favorable tier.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart