The KITOZER 10 A single phase EMI power filter is a high-performance feed-through filter designed for installation on shielded room walls, blocking conducted electromagnetic noise on AC power lines while allowing mains power to pass cleanly into the enclosure. Using a multi-stage pi topology with X and Y capacitors and common-mode chokes, the filter delivers 100 dB insertion loss from 100 kHz to 10 MHz and 60 dB up to 1 GHz, preventing power-line-borne noise from entering the shielded room and conducted emissions from leaking out through the power feed.
Table of Contents
ToggleProduct Overview
This filter is built in a steel wall-mount chassis that bolts directly to the shielded room wall, with the line side outside and the load side inside. The chassis itself is electrically bonded to the wall via a continuous beryllium copper gasket, ensuring that the filter does not become a leakage path around the wall. Standard rating is 10 A at 250 V AC 50 or 60 Hz, suitable for small shielded rooms, equipment racks, and individual EMC test benches. The filter includes terminal blocks on both sides, an integrated discharge resistor, and optional earth bonding cable.
Technical Specifications
Rated current: 10 A continuous. Rated voltage: 250 V AC 50 or 60 Hz. Insertion loss: 100 dB common mode at 100 kHz, 80 dB at 1 MHz, 60 dB at 100 MHz, 40 dB at 1 GHz, measured per CISPR 17. Topology: multi-stage pi, two common-mode chokes plus X and Y capacitors. Leakage current: less than 0.5 mA at 250 V AC. Dielectric withstand: 1500 V AC line to ground for 1 minute. Operating temperature: minus 25 to plus 85 degrees Celsius. Chassis: 2 mm steel, zinc-plated, IP40 front panel. Mounting: wall-mount flange 200 mm by 150 mm, gasketed flange for shielded wall. Terminals: screw terminals 6 square mm both sides. Compliance: CE, UL 60939, CISPR 17, ISO 9001. KITOZER brand, 5 year warranty.
Application Scenarios
This filter is the standard power feed for 40 dB and 60 dB shielded rooms supplying lighting, instrument outlets, and small EUTs. It is used in EMC pre-compliance test rooms, in shielded production line stations, and in RF test enclosures for wireless product verification. Individual filters are also used inside equipment racks to isolate sensitive measurement instruments from rack power distribution. In medical shielded rooms, multiple 10 A filters can be paralleled for higher total current while maintaining the same per-circuit noise isolation. The filter is also suitable for industrial PLC shielded cabinets, laboratory low-noise rooms, and military equipment shelters where conducted emissions must be suppressed.
Advantages and Features
The wall-mount flange design means the filter body is bonded to the shielded wall, avoiding the leakage that occurs when a panel-mount filter is installed through a non-shielded bulkhead. The multi-stage topology provides attenuation across both conducted emission bands (150 kHz to 30 MHz) and radiated coupling bands (30 MHz to 1 GHz), covering the full EMC spectrum. Low leakage current under 0.5 mA makes the filter suitable for medical IT installations per IEC 60939. The chassis is compact, fitting through a standard 200 mm wall cutout, and both side terminal blocks allow straightforward wiring. KITOZER tests each filter for insertion loss before shipment and provides a test curve.
Installation and Maintenance Recommendations
The filter must be installed with the line side outside the shielded room and the load side inside; reversing it negates attenuation. The wall cutout should be sized to the flange, and the flange gasket must be compressed evenly by mounting bolts torqued to 8 Nm. The filter ground terminal must be bonded directly to the shielded room copper busbar with the shortest possible strap, no longer than 200 mm, because inductance in the ground strap reduces high-frequency performance. Power wiring inside the room should be kept short and away from signal cables. Maintenance is limited to annual inspection of terminal tightness and visual check of the flange gasket for corrosion. The filter is a sealed unit and should not be opened; if attenuation degrades, the entire unit is replaced.
KITOZER supports every product with factory documentation including attenuation test certificates, material declarations, dimensional drawings, and installation manuals. Spare gaskets, filters, and consumables are stocked for fast delivery, and the engineering team provides application support for sizing, grounding, and system integration. All products are manufactured under ISO 9001 quality control, with incoming material inspection, in-process testing, and final factory verification before shipment. The stated warranty covers defects in materials and workmanship, and optional extended service contracts are available for critical shielded installations. Customers can request site visit support, on-site acceptance testing, and long-term maintenance planning through the Guangzhou engineering team.
Price
From $280 per filter, including flange gasket and factory insertion loss test curve. Contact +86 13922289957 for higher current ratings.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com