KITOZER Precision Air Conditioner 30kW Up Flow Water Cooled For Data Center

KITOZER 30kW up-flow water-cooled precision air conditioner is designed for medium-sized data halls where outdoor condenser placement is constrained or where chiller water is already available. The water-cooled configuration rejects heat through a shell-and-tube or brazed plate heat exchanger connected to a condenser water loop, eliminating the need for large outdoor air-cooled condensers. Up-flow discharge sends conditioned air through overhead ductwork or directly into the ceiling return plenum, making it suitable for rooms without raised floors or with solid raised floors.

Product Overview

The unit features a high-efficiency scroll compressor, stainless steel water coil, electronic expansion valve, EC plug fans, and a modulating steam humidifier. The controller supports setpoint scheduling, night setback, cyclic redundancy, and energy usage logging. Water-side components include a 3-way modulating control valve, Y-strainer, pressure gauges, and drain connection. The cabinet is constructed from galvanized steel with powder-coated finish, and internal insulation prevents condensation on the outer panels.

Technical Specifications

Nominal cooling capacity 30kW at 24 degrees Celsius DB, 50 percent RH. Water-cooled condenser with entering water temperature 30 to 35 degrees Celsius. Water flow approximately 5.2 cubic meters per hour. Pressure drop around 60 kPa. Airflow 7000 cubic meters per hour. Up-flow configuration. Power supply 380V 3Ph 50Hz. Humidifier 8kg per hour electrode type. Reheat 9kW electric. Cabinet dimensions 1200 millimeters wide, 900 millimeters deep, 2000 millimeters high. CE, ISO certified. KITOZER brand. Five year compressor warranty.

Applications

Typical applications include medium data centers with 30 to 50 racks, co-location facilities, university computer rooms, government data closets, and industrial process control rooms. The water-cooled design is preferred in high-rise urban buildings where roof space is unavailable, or in environments where outdoor air contains corrosive salt spray or heavy dust. It also suits retrofit projects where existing condenser water piping can be reused.

Advantages

Water-cooled chillers deliver superior energy efficiency compared with air-cooled units in warm climates, because condenser water loops run at more favorable temperatures. The up-flow layout simplifies ceiling duct distribution and avoids floor plenum leaks. Precision humidity control prevents static damage to IT equipment. Front serviceability reduces maintenance time. Redundant fan and compressor configurations improve availability.

Installation and Maintenance

Coordinate with the condenser water system designer to ensure water flow, pressure, and water treatment meet unit requirements. Install isolation valves and flexible connectors on both water lines. Flush the piping before connection to avoid debris entering the coil. Clean the Y-strainer quarterly. Descale the water coil annually if water chemistry is hard. Inspect refrigerant leaks with electronic detector during annual service. Keep a spare filter set on site.