KITOZER Precision Power Distribution Column for Data Center Cabinet

Product Overview

The KITOZER precision power distribution column is a rack side or column mounted LV power distribution unit designed for high density data centers and server rooms. It takes 380V three phase input from the UPS or busway and distributes it as monitored single phase or three phase circuits to server cabinets, cooling units, and network gear. Each output circuit has an individual miniature circuit breaker and current sensor, allowing the DCIM system to monitor energy use per cabinet. KITOZER builds the column with dual feed input, redundancy, and remote alarm dry contacts for highest availability.

Technical Specifications

Rated input 380V three phase, 50Hz, 125A or 250A main breaker. Output: 24 to 48 way single phase 16A or 32A circuits with C13, C19, or IEC outlets. Per circuit current monitoring accuracy 1 percent. Dual feed input with automatic switching between source A and source B. Power meter: voltage, current, kW, kVA, kWh, power factor, THD. Communication: Modbus TCP, SNMP, Web HMI. Protection: main MCCB, branch MCB, surge protection Type 2. Cabinet IP30, wall mount or rack mount. Dimensions 600mm by 400mm by 2000mm. Standards IEC 61439, GB 7251, CE.

Application Scenarios

This precision column is deployed in data center server rows, edge computing nodes, telecom central offices, and laboratory test floors. It supplies power to servers, storage arrays, network switches, PDUs, and in row cooling units. The per circuit monitoring supports capacity planning and chargeback by rack.

The per branch current monitoring allows data center operators to know exactly how much power each rack is consuming, supporting capacity planning and chargeback. The dual feed input with automatic ATS means that if source A fails, source B takes over in under 100 milliseconds, avoiding a drop to the rack. The power meter records voltage, current, kW, kVA, kWh, power factor, and THD, and sends the data to the DCIM via Modbus TCP. KITOZER offers options including three phase output sockets, a remote EPO button, and a 4G modem for off site alarming.

Advantages and Features

Per branch current monitoring eliminates guesswork in power capacity. Dual feed input ensures a single UPS path failure does not drop the rack. The touchscreen HMI shows real time load on each branch. KITOZER offers options including three phase output sockets, a remote emergency power off button, and a 4G modem for off site alarming. The column integrates with mainstream DCIM platforms via Modbus TCP.

Installation and Maintenance

Mount the column beside the rack row with cable trays connecting to each cabinet. Connect source A and source B breakers from separate UPS busways. Commissioning: verify phase rotation, test branch breakers, and confirm Modbus communication. Annual maintenance includes torque check on input lugs, MCB operation test, and surge arrester status check. KITOZER recommends a firmware update every two years.

Construction and Quality Assurance

The precision column is fabricated from 1.5mm steel with a powder coated finish. Each output branch has an individual MCB and current sensor. The main incoming MCCB is rated for 250A. The power meter measures voltage, current, kW, kVA, kWh, power factor, and THD. Every unit passes a power frequency withstand, branch circuit test, and Modbus communication test. KITOZER provides a FAT report and wiring diagram. The dual feed ATS switches between source A and source B in under 100 milliseconds.

Packaging and After Sales

The column is shipped in a plywood case. KITOZER provides commissioning support. The 2 year warranty covers meter, breakers, and ATS. Spare MCBs, current sensors, and contactors are stocked. For data centers, KITOZER offers integration support with mainstream DCIM platforms.

KITOZER offers a range of options including three phase output sockets, a remote EPO button, and a 4G modem for off site alarming. The column can be configured as wall mount or floor standing. The per branch current monitoring accuracy is 1 percent. The dual feed ATS switches in under 100 milliseconds. KITOZER provides a full FAT report including a branch circuit test and Modbus communication test. The unit integrates with mainstream DCIM platforms via Modbus TCP.

Price

From $1,880/pc. Contact +86 13922289957 for precision PDU pricing.