1. System Overview

KITOZER Prefabricated Substation (referred to as Prefab Substation) is a prefabricated compact power distribution unit integrating high-voltage switchgear, distribution transformers, low-voltage power distribution equipment and new energy access units. It is compatible with 10kV/35kV high voltage, 0.4kV low voltage, as well as new energy scenarios including photovoltaic, wind power and energy storage. Fully pre-assembled and tested in factory, it features moisture-proof, rust-proof, dust-proof, rodent-proof, fire-resistant, anti-theft, heat-insulated, fully enclosed and movable properties. Serving as an efficient alternative to traditional civil engineering substations, it is widely applied in urban grid renovation, industrial parks, residential communities, new energy power stations, data centers and other scenarios.

Prefabricated Substation

2. System Composition

2.1 High-Voltage Compartment

  • Core Equipment: High-voltage load switch / vacuum circuit breaker, isolating switch, high-voltage fuse, zinc oxide lightning arrester, live display, voltage/current transformer, microcomputer protection device.
  • Functions: Receive 10kV/35kV high-voltage power, realize circuit switching control, fault protection, voltage monitoring and lightning grounding, ensuring safe and stable operation of the high-voltage side.

2.2 Transformer Compartment

  • Core Equipment: Oil-immersed (S13/SH15) / dry-type (SCB14) distribution transformer, temperature controller, cooling fan, lighting system, pressure relief valve, oil level indicator.
  • Functions: Step down high-voltage power to 0.4kV low-voltage power; monitor temperature via temperature control system and automatically start/stop cooling equipment to keep the transformer operating within the rated temperature range.

2.3 Low-Voltage Compartment

  • Core Equipment: Low-voltage incoming cabinet, outgoing cabinet, reactive power compensation cabinet (capacitor/SVG), metering cabinet, intelligent monitoring unit, low-voltage circuit breaker, lightning protector.
  • Functions: Distribute low-voltage power, implement overload/short-circuit protection, electric energy metering, reactive power compensation, harmonic treatment, data collection and remote transmission, guaranteeing power supply quality and reliability on the low-voltage side.

2.4 Optional New Energy Access Unit

  • Core Equipment: Grid-connected inverter, AC power distribution cabinet, anti-reflux device, power quality monitor, grid-connected switch.
  • Functions: Connect photovoltaic/wind power/energy storage systems, realize conversion, grid connection, metering and monitoring of new energy power, and ensure stable compatible operation between new energy and power grid.

Prefab Substation Drawing

2.5 Cabinet & Auxiliary Systems

  • Cabinet: High-quality cold-rolled steel / 304 stainless steel, IP54 outdoor protection grade, windproof, rainproof, dustproof and anti-corrosion.
  • Auxiliary Systems: Lighting, ventilation, dehumidification, fire protection, grounding, optional security monitoring.

3. System Classification

3.1 Classification by Structural Form

  • European Prefab Substation (Combined Type): Independent separated high-voltage, transformer and low-voltage compartments without operation corridor, compact size and high protection grade. Mainly used in industrial parks and residential communities.
  • American Prefab Substation (Integrated Type): High-voltage switches and transformers share an oil tank, around 1/3 the volume of European type with lower cost. Suitable for outdoor simple power distribution and new energy base stations.
  • Assembled Prefab Substation: Separately installed high-low voltage devices and transformers with reserved operation corridor, larger volume and less commonly adopted.

3.2 Classification by Voltage Level

  • High-Voltage Side: 10kV Prefab Substation, 35kV Prefab Substation
  • Low-Voltage Side: Standard 0.4kV (380V/220V) output

3.3 Classification by Application Scenarios

Industrial Workshop Application

  • Conventional Power Distribution Type: Urban grid renovation, residential districts, commercial complexes, industrial parks
  • New Energy Special Type: Photovoltaic prefab substation (12/0.8kV), wind power prefab substation (35/0.4kV), energy storage prefab substation, matching new energy grid connection requirements
  • Industrial Special Type: Data centers, charging pile clusters, mines, metallurgy, chemical industry, with strong overload resistance, high protection grade and anti-harmonic capacity
  • Outdoor Compact Type: Road lighting, scenic spots, remote areas, small size, easy installation and maintenance-free

3.4 Classification by Wiring Mode

  • Terminal Type: Single incoming & single outgoing, for terminal load power supply
  • Ring Network Type: One-in multiple-out / multiple-in one-out, for ring network power supply to improve power supply reliability

4. System Schematic Diagram

4.1 Primary System Schematic (European Ring Network Prefab Substation)

4.2 High-Voltage Side Schematic (10kV)

Incoming line → isolating switch → load switch / circuit breaker → fuse → transformer high-voltage side; parallel lightning arrester, voltage transformer, live display.

4.3 Low-Voltage Side Schematic (0.4kV)

Transformer low-voltage side → incoming circuit breaker → low-voltage busbar → multi-channel outgoing circuit breakers; parallel reactive power compensation cabinet, metering cabinet, lightning protector.

4.4 New Energy Access Schematic (PV + Energy Storage)

PV array → inverter → AC distribution cabinet → prefab substation low-voltage busbar; energy storage system → bidirectional inverter → AC distribution cabinet → prefab substation low-voltage busbar; equipped with anti-reflux device, grid-connected switch and power quality monitor.

5. Full System Configuration List (Basic / Standard / Premium)

On-site Installation

5.1 Basic Configuration List (Economical, for Ordinary Residential & Small Shops)

表格

No.Product NameModel & SpecificationTechnical ParameterQtyUnitBrandRemarks
1Prefab Substation CabinetYBP-12-31510kV/0.4kV, 315kVA, IP54, cold-rolled steel, outdoor type1SetKITOZEREuropean style, 3 separated compartments
2High-Voltage Load SwitchFLN36-1212kV, 630A, 20kA/2s, 3-position, SF6 insulated1UnitKITOZERIncoming cabinet
3High-Voltage FuseXRNT-12/5012kV, 50A, current-limiting, breaking capacity 50kA1PieceKITOZERTransformer protection
4Zinc Oxide Lightning ArresterHY5WZ-17/4517kV, residual voltage 45kV, lightning protection1PieceKITOZERHigh-voltage side
5Oil-Immersed TransformerS13-M-315/1010kV/0.4kV, 315kVA, Dyn11, impedance 4%, fully sealed1UnitKITOZEREnergy-saving, maintenance-free
6Low-Voltage Incoming Circuit BreakerM1-1000/3P1000A, 3P, fixed type, electromagnetic trip1UnitKITOZERIncoming cabinet
7Low-Voltage Outgoing Circuit BreakerM1-250/3P250A, 3P, fixed type, 4 circuits4UnitKITOZEROutgoing cabinet
8Low-Voltage Outgoing Circuit BreakerM1-160/3P160A, 3P, fixed type, 2 circuits2UnitKITOZEROutgoing cabinet
9Reactive Power Compensation CapacitorBSMJ-0.45-20-30.45kV, 20kvar, 3-phase, self-healing6UnitKITOZERCompensation cabinet, total 120kvar
10Compensation ControllerJKL5F-1212 loops, automatic switching, power factor 0.951UnitKITOZERCompensation cabinet
11Electric Energy MeterDT862-43-phase 4-wire, 380V, 5A, mechanical type1PieceKITOZERMetering cabinet
12Cabinet Auxiliary SystemCustomizedLighting, ventilation, dehumidification, grounding1SetKITOZERStandard equipped

5.2 Standard Configuration List (Standard Type, for Industrial Parks & Commercial Complexes)

表格

No.Product NameModel & SpecificationTechnical ParameterQtyUnitBrandRemarks
1Prefab Substation CabinetYBP-12-80010kV/0.4kV, 800kVA, IP54, 304 stainless steel, outdoor type1SetKITOZEREuropean style, 3 compartments, upgraded anti-corrosion
2High-Voltage Vacuum Circuit BreakerVS1-12/63012kV, 630A, 25kA/2s, draw-out type, permanent magnet operation1UnitKITOZERIncoming cabinet, ring network type
3Microcomputer Protection DeviceKZ-100010kV, overcurrent / instantaneous trip / overvoltage / undervoltage / zero-sequence protection1UnitKITOZERHigh-voltage cabinet, intelligent protection
4High-Voltage FuseXRNT-12/12512kV, 125A, current-limiting, breaking capacity 50kA1PieceKITOZERTransformer protection
5Zinc Oxide Lightning ArresterHY5WZ-17/4517kV, residual voltage 45kV, lightning protection2PieceKITOZERHigh-voltage + low-voltage side
6Dry-Type TransformerSCB14-800/1010kV/0.4kV, 800kVA, Dyn11, impedance 6%, flame retardant1UnitKITOZEREnergy-saving, fireproof, temperature control linkage
7Low-Voltage Incoming Circuit BreakerDW45-2000/3P2000A, 3P, draw-out type, intelligent trip1UnitKITOZERIncoming cabinet
8Low-Voltage Outgoing Circuit BreakerM2-400/3P400A, 3P, fixed type, 6 circuits6UnitKITOZEROutgoing cabinet
9Intelligent Reactive Power Compensation CabinetTBB-0.4-2400.4kV, 240kvar, automatic intelligent switching, harmonic suppression1SetKITOZERSVG + capacitor hybrid compensation
10Electric Energy MeterDTSD8623-phase 4-wire, 380V, 1.5(6)A, electronic multi-function1PieceKITOZERMetering cabinet, remote transmission
11Intelligent Monitoring UnitKZ-MONData collection, remote transmission, alarm, temperature control linkage1UnitKITOZERSystem monitoring
12Cabinet Auxiliary SystemCustomizedLighting, ventilation, dehumidification, fire protection, grounding, security1SetKITOZERUpgraded configuration

5.3 Premium Configuration List (High-End Type, for Data Centers, New Energy Stations & Charging Pile Clusters)

表格

No.Product NameModel & SpecificationTechnical ParameterQtyUnitBrandRemarks
1Prefab Substation CabinetZGSB-12-200010kV/0.4kV, 2000kVA, IP55, 304 stainless steel + anti-corrosion coating, outdoor type1SetKITOZEREuropean/American optional, C5-M anti-corrosion grade
2High-Voltage Vacuum Circuit BreakerZN63A-12/125012kV, 1250A, 31.5kA/2s, draw-out type, intelligent operation1UnitKITOZERRing network incoming, dual power supply
3Microcomputer Protection & Measurement DeviceKZ-200010kV, integrated protection, measurement & communication, IEC61850 compliant1UnitKITOZERHigh-voltage cabinet, intelligent operation & maintenance
4High-Voltage FuseXRNT-12/25012kV, 250A, current-limiting, breaking capacity 63kA1PieceKITOZERTransformer protection
5Zinc Oxide Lightning ArresterHY5WZ-17/45+HY1.5W-0.5/2.6Full lightning protection for high & low voltage sides3PieceKITOZERFull system lightning protection
6Amorphous Alloy TransformerSH15-2000/1010kV/0.4kV, 2000kVA, Dyn11, impedance 6%, ultra-low loss1UnitKITOZEREnergy-saving, noise ≤50dB
7Low-Voltage Incoming Circuit BreakerDW45-4000/3P4000A, 3P, draw-out type, intelligent trip with communication port1UnitKITOZERIncoming cabinet
8Low-Voltage Outgoing Circuit BreakerM3-630/3P630A, 3P, draw-out type, 8 circuits8UnitKITOZEROutgoing cabinet with communication
9Static Var Generator (SVG)SVG-0.4-5000.4kV, 500kvar, dynamic compensation, harmonic treatment (THDi≤5%)1SetKITOZERReactive power compensation + power quality treatment
10Multi-Function Power Quality AnalyzerPQM-3000Voltage/current/harmonic/power/frequency monitoring, storage & remote transmission1UnitKITOZERMetering cabinet, high-precision metering
11New Energy Grid-Connected CabinetKZ-PV-500PV/wind power access, anti-reflux, grid connection protection, power monitoring1SetKITOZERSpecial for new energy
12Intelligent Operation & Maintenance SystemKZ-IOTRemote monitoring, fault diagnosis, data analysis, APP linkage1SetKITOZERCloud operation & maintenance
13Cabinet Auxiliary SystemCustomizedLighting, ventilation, dehumidification, fire protection, grounding, HD security, temperature & humidity monitoring1SetKITOZERTop-tier configuration

6. Full Product Technical Parameters

6.1 Prefab Substation Cabinet Technical Parameters

  • Rated Voltage: High voltage 10kV/35kV, low voltage 0.4kV
  • Rated Capacity: 30kVA~5000kVA
  • Protection Grade: IP54 (Standard) / IP55 (Premium)
  • Cabinet Material: Cold-rolled steel (Basic) / 304 stainless steel (Standard & Premium) / C5-M anti-corrosion coating (Premium)
  • Ambient Temperature: -40℃~+55℃
  • Altitude: ≤2000m
  • Relative Humidity: ≤95% (No condensation)

Internal Section Drawing

6.2 High-Voltage Switchgear Technical Parameters

  • Rated Voltage: 12kV (10kV system) / 40.5kV (35kV system)
  • Rated Frequency: 50Hz
  • Rated Current: 630A/1250A/2000A
  • Rated Short-Circuit Breaking Current: 20kA/25kA/31.5kA
  • Rated Short-Circuit Withstand Current: 20kA/25kA/31.5kA (2s)
  • Insulation Level: 1min power frequency withstand voltage 42kV, lightning impulse withstand voltage 75kV

6.3 Distribution Transformer Technical Parameters

  • Oil-Immersed Type (S13-M): Rated voltage 10kV/0.4kV, impedance 4%~6%, no-load loss ≤1.2kW, load loss ≤10kW (800kVA), Dyn11 connection group
  • Dry-Type Type (SCB14): Rated voltage 10kV/0.4kV, impedance 6%~8%, no-load loss ≤1.0kW, load loss ≤8.5kW (800kVA), Dyn11 connection group, F-class flame retardant
  • Amorphous Alloy Type (SH15): Rated voltage 10kV/0.4kV, impedance 6%, no-load loss ≤0.3kW, load loss ≤9.2kW (2000kVA), ultra-low loss, energy saving over 30%

6.4 Low-Voltage Switchgear Technical Parameters

  • Rated Voltage: 0.4kV
  • Rated Frequency: 50Hz
  • Rated Current: 1000A/2000A/4000A (Incoming), 160A/250A/400A/630A (Outgoing)
  • Rated Short-Circuit Breaking Capacity: 50kA/65kA/80kA
  • Trip Characteristics: Long delay, short delay, instantaneous three-stage protection

6.5 Reactive Power Compensation Equipment Technical Parameters

Internal Equipment Inspection

  • Capacitor Compensation Cabinet: Rated voltage 0.45kV, single unit capacity 20kvar~50kvar, 3-phase self-healing, loss ≤0.1%
  • SVG Static Var Generator: Rated voltage 0.4kV, capacity 100kvar~500kvar, response time ≤10ms, harmonic treatment THDi≤5%, power factor compensation range -1~+1

6.6 Intelligent Monitoring Equipment Technical Parameters

  • Data Collection Accuracy: Voltage ±0.2%, Current ±0.2%, Power ±0.5%
  • Communication Interface: RS485, Ethernet, 4G/5G (Premium)
  • Operating Power Supply: AC220V/DC24V
  • Temperature Monitoring Range: -40℃~+125℃, Accuracy ±0.5℃

7. Full Product Application Scope

7.1 Conventional Power Distribution Scenarios

  • Urban grid renovation, old community upgrading, residential districts, commercial complexes, office buildings, hotels
  • Industrial parks, standard factories, warehouses, logistics parks, small & medium enterprise power distribution
  • Municipal engineering, road lighting, parks, scenic spots, airports, ports, stations

7.2 New Energy Scenarios

  • Centralized/distributed photovoltaic power stations, wind farms, energy storage power stations, matching 12/0.8kV, 35/0.4kV voltage levels
  • Charging pile clusters, battery swapping stations, new energy automobile industrial parks, high overload & high reliability power distribution

7.3 Industrial Special Scenarios

Intelligent Monitoring Control Room

  • Data centers, cloud computing centers, server rooms, dual power supply, high reliability, low harmonic power supply
  • Mines, metallurgy, chemical industry, petroleum & natural gas, high protection, anti-corrosion, optional explosion-proof
  • Medical, education, scientific research institutions, precision power supply, low noise & low interference

7.4 Special Environment Scenarios

  • Remote outdoor areas, mountainous regions, forest zones, pastoral areas, moisture-proof, dust-proof, rodent-proof, maintenance-free
  • High temperature, low temperature, high humidity, salt fog, corrosive environments (coastal areas, chemical plants), IP55 protection & anti-corrosion coating

8. Full Product Advantages

8.1 Functional Features

  • Integrated Design: Integrated high-voltage, transformer, low-voltage and new energy units, fully pre-assembled & tested in factory; on-site installation only takes 3-7 days, cutting construction period by 80% compared with traditional civil substations
  • High Reliability: Fully enclosed metal cabinet with IP54/IP55 protection, moisture/rust/dust/rodent/fire/theft resistant, adapting to extreme environment of -40℃~+55℃, maintenance-free for outdoor operation
  • Energy-Saving & High Efficiency: Adopt S13/SH15/SCB14 energy-saving transformers, no-load loss reduced by 30%~70%; intelligent reactive power compensation + SVG harmonic treatment, power factor raised above 0.95, power saving rate 10%~20%
  • Flexible Capacity Expansion: Modular design supporting parallel capacity expansion, capacity increase completed within 48 hours to adapt to flexible load growth
  • Intelligent Operation & Maintenance: Premium models equipped with KZ-IOT cloud O&M system, realizing remote monitoring, fault diagnosis, data analysis & APP linkage, unattended operation and lower maintenance cost

8.2 Customized Services

Outdoor Prefab Substation

  • Size Customization: Custom cabinet dimensions according to site space, adapting to narrow sites or special layout requirements
  • Configuration Customization: Optional Basic/Standard/Premium grades, add/remove high-voltage cabinet, low-voltage cabinet, compensation cabinet and new energy access units as required, matching different load levels and budgets
  • Function Customization: Custom dual power switching, anti-reflux, harmonic treatment, explosion-proof, lightning protection, security monitoring functions for new energy, industrial and special environment scenarios
  • Appearance Customization: Custom cabinet color, logo and coating to match the overall visual style of projects

8.3 OEM & Confidentiality Service

  • OEM/ODM Processing: Support customer brand OEM production, provide full technical solutions & manufacturing services, sufficient production capacity & short delivery time
  • Technical Confidentiality: Sign confidentiality agreements to strictly protect customers’ technical schemes, drawings, parameters and other core data, prevent technical leakage

8.4 Spot Supply

  • Spot Inventory for Standard Models: Regular capacities including 315kVA, 500kVA, 800kVA, 1000kVA prefab substations and supporting equipment (high-voltage switches, transformers, low-voltage circuit breakers, compensation devices) kept in stock for fast delivery & shorter project cycle

8.5 Full Series Technical Parameter Advantages

  • Wide Voltage Adaptation: Covering 10kV/35kV high voltage, 0.4kV low voltage, 12/0.8kV PV special voltage, adapting to full-scenario power distribution demands
  • Full Capacity Coverage: Capacity ranging from 30kVA to 5000kVA, meeting power demands from small shops to large industrial & new energy power stations
  • High Insulation Grade: High-voltage equipment insulation level reaches 42kV (power frequency) /75kV (lightning), low-voltage equipment insulation level 2kV for safe & reliable operation
  • Strong Overload Capacity: Transformers support 1.2x long-term overload & 1.5x short-term overload to cope with load fluctuation and impact loads

9. Bid Winning Technical Parameters (★ Marked Mandatory Items)

9.1 Prefab Substation Cabinet Bid Winning Parameters

★1. Cabinet Material: 304 stainless steel (Standard & Premium), thickness ≥2mm, C5-M anti-corrosion grade, salt fog corrosion resistance ≥5000h

★2. Protection Grade: Outdoor type ≥IP54, dustproof & waterproof, resistant to heavy rain and sandstorm

★3. Ambient Temperature: Adapt to extreme temperature -40℃~+55℃, operate without derating under high temperature

★4. Structural Form: European prefab substation adopts independent 3-compartment separation (high-voltage compartment / transformer compartment / low-voltage compartment) to prevent fault propagation

9.2 High-Voltage Switchgear Bid Winning Parameters

★1. Rated Voltage: 12kV (10kV system), rated frequency 50Hz

★2. Rated Short-Circuit Breaking Current: ≥25kA, rated short-circuit withstand current ≥25kA (2s), realizing fast cut-off during faults

★3. Insulation Level: 1min power frequency withstand voltage ≥42kV, lightning impulse withstand voltage ≥75kV, safe & reliable insulation

★4. Operation Mode: Vacuum circuit breaker adopts permanent magnet operating mechanism, mechanical service life ≥10,000 times with high reliability

9.3 Distribution Transformer Bid Winning Parameters

★1. Rated Voltage: 10kV/0.4kV, Dyn11 connection group, impedance voltage 4%~6%

★2. Energy Efficiency Grade: Oil-immersed ≥S13, dry-type ≥SCB14, amorphous alloy ≥SH15; no-load loss 10% lower than national standard

★3. Noise Level: ≤50dB (2000kVA), low noise design suitable for residential, medical and other noise-sensitive areas

★4. Protection Grade: Dry-type transformer protection grade ≥IP20 to prevent foreign matter intrusion and ensure safety

9.4 Low-Voltage Switchgear Bid Winning Parameters

★1. Rated Voltage: 0.4kV, rated frequency 50Hz

★2. Rated Short-Circuit Breaking Capacity: Incoming circuit breaker ≥65kA, outgoing circuit breaker ≥50kA, fast breaking under short circuit to protect equipment

★3. Trip Characteristics: Equipped with long delay, short delay, instantaneous three-stage protection, accurately matching load characteristics to reduce misoperation

★4. Communication Interface: Premium circuit breakers equipped with RS485/Ethernet communication port to support remote monitoring & operation

9.5 Reactive Power Compensation Equipment Bid Winning Parameters

★1. Capacitor Compensation Cabinet: Rated voltage 0.45kV, self-healing capacitor, loss ≤0.1%, service life ≥50,000h

★2. SVG Static Var Generator: Response time ≤10ms, harmonic treatment THDi≤5%, power factor compensation range -1~+1, excellent dynamic compensation effect

9.6 Intelligent Monitoring Equipment Bid Winning Parameters

★1. Data Collection Accuracy: Voltage ±0.2%, Current ±0.2%, Power ±0.5%, accurate monitoring of electrical parameters

★2. Communication Interface: Dual communication of 4G/5G + Ethernet to ensure stable data transmission and uninterrupted remote operation & maintenance

★3. Temperature Monitoring Range: -40℃~+125℃, accuracy ±0.5℃, real-time transformer temperature monitoring linked with cooling system

10. Full Product Solutions

Multiple Prefab Substation Products

10.1 Conventional Power Distribution Solution (Residential / Commercial / Industrial Parks)

  • Configuration Scheme: European prefab substation with capacity 315kVA~2000kVA; high-voltage side equipped with load switch / vacuum circuit breaker + microcomputer protection; S13/SCB14 energy-saving transformer; low-voltage side with incoming + multi-channel outgoing + intelligent reactive power compensation (capacitor/SVG) + multi-function metering; IP54 protection grade, outdoor ground installation
  • Solution Advantages: Moderate cost, convenient installation, stable operation & simple maintenance, matching conventional load demands with stable power supply quality complying with national grid standards
  • Applicable Scenarios: Residential districts, commercial complexes, industrial parks, municipal engineering, road lighting

10.2 New Energy Special Solution (PV / Wind Power / Energy Storage)

  • Configuration Scheme: New energy special prefab substation (ZGSB-12/ZGSF-35), capacity 500kVA~5000kVA; high-voltage side vacuum circuit breaker + intelligent protection; SH15 amorphous alloy ultra-low loss transformer; low-voltage side equipped with new energy grid-connected cabinet + anti-reflux device + SVG harmonic treatment + power quality monitoring, supporting multi-source access of PV/wind power/energy storage; IP55 protection, wind/sand/low temperature/salt fog resistant
  • Solution Advantages: Matching new energy grid connection characteristics, excellent anti-reflux & harmonic treatment effect, compliant power quality, ultra-low loss energy saving, adapting to harsh environments of wind & PV power stations
  • Applicable Scenarios: Centralized PV power stations, distributed PV power stations, wind farms, energy storage power stations, new energy microgrids

10.3 Data Center / Charging Pile Cluster Solution

  • Configuration Scheme: High-end prefab substation with capacity 1000kVA~2000kVA, dual power incoming; high-voltage side intelligent microcomputer protection; SCB14 dry-type fireproof transformer; low-voltage side draw-out circuit breaker + dual power switching + SVG dynamic compensation + harmonic treatment + intelligent O&M system, redundant design with high reliability to guarantee 7×24h uninterrupted power supply
  • Solution Advantages: Dual power redundancy, high reliable power supply, low harmonic & fast response, adapting to heavy & impact load characteristics of data centers and charging pile clusters, power quality meeting precision equipment requirements
  • Applicable Scenarios: Data centers, cloud computing centers, charging pile clusters, battery swapping stations, large commercial complexes

10.4 Special Environment Solution (High/Low Temperature, Salt Fog, Corrosion)

  • Configuration Scheme: Reinforced anti-corrosion prefab substation, IP55 protection, 304 stainless steel + C5-M anti-corrosion coating; wide-temperature high/low voltage equipment; high/low temperature resistant transformer; additional dehumidification/heating/ventilation devices with temperature control linkage, adapting to -40℃~+55℃ extreme environment, salt fog/corrosion/mold resistant
  • Solution Advantages: Strong adaptability to extreme environments, excellent anti-corrosion performance, long-term operation without rust or failure, maintenance-free and lower operation cost
  • Applicable Scenarios: Coastal areas, chemical plants, mines, metallurgy, high-temperature deserts, cold frozen soil regions

11. Full Product Application Cases

11.1 Industrial Park Power Distribution Project

  • Project Overview: Covering 500,000 ㎡ with 50 settled enterprises, total load 8000kVA, adopting 8 sets of KITOZER European prefab substations (1000kVA each), 10kV ring network power supply, 0.4kV power distribution, equipped with intelligent reactive power compensation & harmonic treatment, outdoor ground installation
  • Project Effect: Installation period 30 days, 4 months shorter than traditional civil substation; zero fault in 2 years of operation, power factor stably maintained at 0.98, power saving rate 15%, power supply reliability reaching 99.99%, meeting production power demands of park enterprises

11.2 10MW PV Power Station Project

  • Project Overview: Distributed PV power station with installed capacity 10MW, adopting 5 sets of KITOZER PV special prefab substations (2000kVA each), 12/0.8kV voltage level connected to 35kV power grid, equipped with anti-reflux device + SVG harmonic treatment + intelligent monitoring system, outdoor mountain installation
  • Project Effect: Adapt to intermittent output characteristics of PV, excellent anti-reflux performance, harmonic THDi≤3% with compliant power quality; amorphous alloy transformer with low no-load loss saving around 200,000 kWh per year; stable operation adapting to mountain wind & sand environment, unattended operation with low maintenance cost

11.3 Data Center Power Distribution Project

  • Project Overview: Medium-sized data center with 2,000 server cabinets, total load 4000kVA, adopting 2 sets of KITOZER high-end prefab substations (2000kVA each), dual power incoming, 10kV/0.4kV, SCB14 dry-type transformer, SVG dynamic compensation + harmonic treatment + intelligent O&M system, indoor installation
  • Project Effect: Dual power redundant power supply with reliability reaching 99.999%, meeting data center 7×24h uninterrupted power supply requirements; excellent harmonic treatment with THDi≤4% to protect precision server equipment; remote monitoring via intelligent O&M system with timely fault early warning, maintenance efficiency improved by 80%

11.4 Coastal High-End Residential Power Distribution Project

  • Project Overview: Coastal high-end residential district with 1,200 households, total load 2500kVA, adopting 5 sets of KITOZER anti-corrosion prefab substations (500kVA each), IP55 protection, 304 stainless steel + C5-M anti-corrosion coating, 10kV/0.4kV, outdoor ground installation
  • Project Effect: Adapt to coastal salt fog corrosion environment, zero rust & zero fault after 3 years of operation; low noise design (≤50dB) without disturbing residents; remote meter reading via intelligent metering system for convenient payment, improving residents’ power consumption experience

12. Product Common Faults & Maintenance

12.1 Common Faults & Solutions

12.1.1 High-Voltage Side Faults

  • Fault Phenomenon: High-voltage circuit breaker tripping, fuse blown, lightning arrester breakdown, no indication on live display
  • Fault Causes: Line short circuit, overload, lightning overvoltage, insulation aging, poor contact
  • Solutions: ① Cut off high-voltage power supply immediately, hang warning signs, forbid live operation; ② Check lines, cable heads and insulators for damage or flashover traces; ③ Replace blown fuses and broken lightning arresters; ④ Test insulation resistance, restore power supply after passing test; ⑤ Check protection fixed value and secondary circuit if relay protection misoperates

12.1.2 Transformer Faults

  • Fault Phenomenon: Excess oil temperature, abnormal noise, oil leakage, gas relay action, temperature controller alarm
  • Fault Causes: Overload, poor heat dissipation, low oil level, insulation aging, loose iron core, winding short circuit
  • Solutions: ① Reduce load, check cooling fan operation, clean dust on heat sink; ② Check oil level, supplement same-type insulating oil and repair oil leakage points; ③ Test winding insulation resistance & DC resistance to judge winding short circuit; ④ Take gas sample for analysis if gas relay acts to identify fault causes; ⑤ Conduct core lifting maintenance and replace aging insulation materials if necessary

12.1.3 Low-Voltage Side Faults

  • Fault Phenomenon: Low-voltage circuit breaker tripping, no power on outgoing lines, failed reactive power compensation switching, abnormal metering
  • Fault Causes: Line short circuit, overload, electric leakage, damaged capacitor, faulty compensation controller, defective energy meter
  • Solutions: ① Cut off faulty loop circuit breaker, check lines for short circuit & leakage; ② Reduce load and adjust circuit breaker trip fixed value; ③ Check capacitors for bulge & oil leakage, replace damaged capacitors; ④ Calibrate compensation controller and inspect wiring; ⑤ Verify energy meter and replace faulty meters

12.1.4 Cabinet & Auxiliary System Faults

  • Fault Phenomenon: Cabinet rust, damaged door lock, non-luminous lighting, failed dehumidification, no monitoring signal
  • Fault Causes: Environmental corrosion, mechanical damage, poor circuit contact, equipment aging
  • Solutions: ① Clean rusted areas and re-coat anti-corrosion paint; ② Replace damaged door locks, lighting lamps and dehumidifiers; ③ Inspect monitoring lines and communication modules to restore signals; ④ Regularly check grounding system to ensure grounding resistance ≤4Ω

12.2 Maintenance Regulations

12.2.1 Daily Maintenance (Daily Inspection)

  • Check cabinet appearance for rust, deformation and damage; door locks and sealing strips intact
  • Observe normal indicator lights and instruments of high/low voltage equipment, no abnormal noise or odor
  • Check normal transformer oil temperature & oil level without oil leakage, automatic start/stop of cooling fans
  • Check normal operation of reactive power compensation cabinet & SVG with qualified power factor
  • Check normal data transmission of monitoring system without alarm information

12.2.2 Monthly Maintenance

  • Clean internal dust & sundries of cabinet to keep good ventilation
  • Tighten wiring terminals of high/low voltage equipment to prevent heating from poor contact
  • Test transformer insulation resistance (High voltage to ground ≥1000MΩ, Low voltage to ground ≥500MΩ)
  • Check intact high-voltage fuses, lightning arresters and live displays without aging & damage
  • Calibrate low-voltage energy meter and compensation controller to ensure accurate metering & normal switching
  • Inspect grounding system and test grounding resistance ≤4Ω

12.2.3 Annual Maintenance

  • Comprehensive overhaul of high-voltage switchgear, test mechanical & electrical properties and lubricate operating mechanism
  • Oil sample test of transformer, detect dielectric loss & breakdown voltage of insulating oil, replace oil if necessary
  • Full calibration of low-voltage circuit breakers, adjust trip fixed value and test closing & breaking performance
  • Comprehensive inspection of reactive power compensation capacitors & SVG, replace aging & damaged components
  • Inspect cabinet anti-corrosion coating and re-coat rusted areas to extend service life
  • Full debugging of intelligent monitoring system, software upgrade and parameter calibration

13. Factory Strength & After-Sales Service

13.1 Factory Strength

  • Production Scale: Modern production base covering 30,000 ㎡ with 20,000 ㎡ workshops, annual output of 10,000 sets of prefab substations and supporting equipment, highly automated production lines equipped with advanced equipment (CNC punch, laser cutting machine, bending machine, high/low voltage test bench, transformer test bench)
  • R&D Technology: 50 professional R&D engineers including 15 senior engineers focusing on prefab substation and high-low voltage power distribution equipment R&D, holding 20 patents (utility model & invention patents), participating in formulation of multiple industry standards with domestically leading technology
  • Quality Control: Strictly implement ISO9001 Quality Management System, ISO14001 Environmental Management System, ISO45001 Occupational Health & Safety Management System; strict screening of raw materials from well-known brands, full inspection during production, 100% high/low voltage/transformer/protection system test before delivery to guarantee qualified products
  • Delivery Capacity: Standard models (315kVA~2000kVA) kept in stock for delivery within 7 days; customized models delivered within 15~30 days with sufficient production capacity and short delivery cycle to meet urgent project demands

13.2 After-Sales Service

  • Warranty Period: 3-year product warranty with lifetime maintenance; free repair & component replacement for non-artificial damage within warranty, 24-hour service response
  • Installation & Commissioning: Free on-site installation guidance & commissioning service with professional technicians to ensure normal equipment operation; provide installation drawings, technical disclosure and operation training
  • Technical Training: Free operation, maintenance and fault handling training for customers via online & offline modes to ensure staff master equipment operation & maintenance skills proficiently
  • Emergency Service: 24-hour emergency hotline, response within 2 hours after fault report, on-site arrival within 4 hours (domestic) for fast fault handling to reduce power outage loss; coordinate nearby service outlets for remote areas
  • Spare Parts Supply: Full series product spare parts kept in stock with preferential supply after warranty period to guarantee long-term stable equipment operation without worries
  • Upgrade Service: Free software upgrade & technical transformation scheme to adapt to customer’s later capacity expansion & function upgrade demands and extend equipment service life

14. Conclusion

As an integrated, intelligent and energy-saving new power distribution equipment, KITOZER Prefabricated Substation integrates high-voltage, low-voltage and new energy access technologies, featuring small floor area, convenient installation, stable operation, simple maintenance, high energy efficiency, flexible capacity expansion and intelligent operation & maintenance. It meets full-scenario demands including conventional power distribution, new energy, industry and special environments.

Supported by strong R&D strength, advanced production equipment, strict quality control and complete after-sales service, our company provides high-quality prefab substation products and customized solutions for customers, helping efficient project implementation, stable operation and energy saving & consumption reduction. In the future, we will continue technological innovation, optimize product performance and upgrade service quality to contribute to the development of power industry and energy transformation.

15. Search Keywords, SEO & Tags

15.1 Search Keywords

Prefabricated Substation, KITOZER Prefab Substation, 10kV Prefabricated Substation, 35kV Prefab Substation, European Prefab Substation, American Prefab Substation, PV Prefab Substation, Wind Power Prefab Substation, Energy Storage Prefab Substation, New Energy Prefab Substation, Data Center Prefab Substation, Charging Pile Prefab Substation, Prefabricated Substation Solution, Prefab Substation Configuration List, Prefab Substation Technical Parameters, Prefab Substation Application Cases, Prefab Substation Maintenance

15.2 SEO Optimization

  • Core Keywords: Prefabricated Substation, KITOZER Prefab Substation, 10kV Prefab Substation, European Prefab Substation, PV Prefab Substation
  • Long-Tail Keywords: Prefabricated Substation Solution, Basic/Standard/Premium Prefab Substation Configuration, Prefab Substation Technical Parameters, Prefab Substation Application Scope, Prefab Substation Fault Maintenance, New Energy Prefab Substation Solution, Data Center Prefab Substation Configuration
  • Page Optimization: Title contains core keywords, natural keyword embedding in detail page, picture ALT tags marked with keywords, internal links associated with prefab substation related products & solutions, external links guiding traffic to authoritative power industry websites

15.3 Tags

#PrefabricatedSubstation #KITOZERPrefabSubstation #10kVPrefabSubstation #EuropeanPrefabSubstation #AmericanPrefabSubstation #PVPrefabSubstation #NewEnergyPrefabSubstation #DataCenterPrefabSubstation #ChargingPilePrefabSubstation #PrefabSubstationSolution #HighLowVoltageDistribution #IntelligentO&M #EnergySavingDistribution

Shopping Cart