KITOZER Pressure Regulating Skid & Skid-Mounted Equipment Room Quotation List
Table of Contents
Toggle2. Project Requirement Description
Engineering Environment
- Location: Site located in a mid-temperate continental arid climate zone
- Extreme low temperature: -42.7°C; extreme high temperature: 40.0°C
- Maximum frozen soil depth: 1.85 m; maximum snow accumulation: 980 mm
- Seismic resistance, wind/sand protection, and lightning protection requirements apply
Skid-Mounted Equipment Room – Basic Requirements
- External dimensions: 10,000 × 3,600 × 3,000 mm (L × W × H)
- Net internal height ≥ 2.8 m; net internal width ≥ 3.6 m
- Wall insulation: ≥ 100 mm rock wool sandwich color steel plate, resistant to -46°C
- Maintenance-free period ≥ 10 years; anti-corrosion life ≥ 5 years
- Coating: sandblasting and rust removal, 2 coats primer + 2 coats acrylic polyurethane topcoat
Electrical & Control Systems
- Power distribution box (explosion-proof, Exdb IIB T4); analog/switch signal junction boxes
- Lightning protection grounding: grounding copper plate 300 × 300 × 10 mm; grounding conductor ≥ 160 mm²
- Emergency lighting centralized power supply (duration ≥ 90 min); evacuation indication
- Cabinet support brackets and removable cover plates: channel steel [80 × 43 × 5, galvanized, fireproof, waterproof, dustproof
- Fire automatic alarm system (supplied complete by skid manufacturer)
- Fire alarm controller: wall-mounted, backup power ≥ 8 h
- Intelligent power box: DC 24 V, 4 A, battery backup ≥ 3 h
- Explosion-proof photoelectric smoke detectors, manual alarm buttons, audible/visual alarm devices
- Bus isolators, input/output modules, module boxes
- Cable-type linear heat detector (heat-sensing cable 60 m)
- Signal/power surge protectors
Access Control System
- Explosion-proof card readers, electromagnetic locks, door magnetic switches (switching output, transmitted remotely to the superior station)
HVAC
- Split wall-mounted air conditioner (cooling capacity 7,200 W, supports heating at -40°C)
- Explosion-proof electric heaters (3 kW × 2 units), ensuring indoor temperature ≥ 18°C in winter and ≤ 25°C in summer
Fire-Fighting Equipment
- MT7 portable carbon dioxide fire extinguishers (2 units), with stainless steel extinguisher box
Clarification Document – Special Notes
- Fire alarm system, access control system, and intelligent power box are supplied by the skid manufacturer
- UPS, network cabinet, video surveillance, SIS/PLC/metering cabinets, and combustible gas alarms are outside the scope of supply; however, cabinet support brackets and placement positions shall be provided
- No signal adapter box is required; instrument cables shall be routed through the floor interlayer
- The pressure regulating skid system itself is provided by Party A and is NOT included in this quotation
3. System Composition Introduction
The quotation covers a complete skid-mounted equipment room and associated systems, composed of the following major subsystems:
- Skid-Mounted Room Body: Includes the prefabricated color steel room shell, steel structure base, doors/windows, interior finishing, painting system, foundation embedded parts, cabinet brackets with removable cover plates, and stainless steel nameplate.
- Electrical Equipment, Materials, Installation & Commissioning: Includes explosion-proof power distribution box, analog and switching signal junction boxes, explosion-proof LED lighting, lightning protection and grounding system, cables and cable trays, low-voltage switchgear/control devices, emergency lighting centralized power supply with evacuation indication, cable entry sealing cover plates, and full electrical installation/commissioning.
- Fire Alarm System: Wall-mounted fire alarm controller, explosion-proof photoelectric smoke detectors, manual alarm buttons, audible/visual alarms, bus isolators, input/output modules, module boxes, cable-type linear heat detector, intelligent power box, surge protectors, system wiring, and commissioning.
- Access Control System: Access control controller, explosion-proof inductive card reader, electromagnetic lock, door magnetic switch, exit button, wiring, and installation/commissioning.
- HVAC System: Split wall-mounted air conditioner, explosion-proof electric heaters, installation accessories, and commissioning.
- Fire-Fighting Equipment: MT7 portable CO₂ fire extinguishers and stainless steel extinguisher box.
4. Core Product Specifications & Parameters
| Item | Specification / Parameter |
|---|---|
| Skid-Mounted Room Dimensions | 10,000 × 3,600 × 3,000 mm (L × W × H) |
| Wall Construction | ≥ 100 mm rock wool sandwich color steel plate, resistant to -46°C |
| Steel Structure Base | Profile steel welded, integral anti-corrosion, pre-drilled bolt holes / grounding terminals |
| Doors & Windows | 1 anti-theft door with door closer, 2 observation windows, sealing IP54 |
| Interior | Anti-slip anti-static floor; leveling treatment on walls and ceiling |
| Painting | Sandblasting rust removal; 2 coats primer + 2 coats acrylic polyurethane topcoat; anti-corrosion ≥ 5 years; per SY/T 0319 |
| Foundation Embedded Parts | Embedded steel plates, anchor bolts and gaskets |
| Cabinet Brackets | Channel steel [80 × 43 × 5, Q235B galvanized, with removable cover plates, fire/water/dust-proof |
| Power Distribution Box (AP03) | Wall-mounted, explosion-proof, Exdb IIB T4, IP65 |
| Signal Junction Boxes (JE/JD) | Explosion-proof, Exdb IIB T4, IP65, 15% terminal reserve |
| Skid Lighting | Explosion-proof LED, Exdb IIB T4, IP65, ≥ 20 W |
| Lightning Protection Grounding | Grounding copper plate 300 × 300 × 10 mm; grounding conductor ≥ 160 mm²; per GB 50303 |
| Fire Alarm Controller | Wall-mounted, with audible/visual alarm, backup power ≥ 8 h |
| Smoke Detectors | Explosion-proof, Exdb IIB T4, IP65 |
| Manual Alarm Button | Explosion-proof, Exdb IIB T4, IP65, with telephone jack |
| Audible/Visual Alarm | Explosion-proof, Exdb IIB T4, IP65, sound pressure level ≥ 85 dB |
| Intelligent Power Box | DC 24 V, 4 A, built-in battery backup ≥ 3 h |
| Bus Isolator | Non-polar two-bus, automatic short-circuit isolation |
| Input/Output Module | Non-polar two-bus, DC 24 V, contact capacity 2 A |
| Linear Heat Detector | Fixed temperature 85°C, includes microprocessor modulator, terminal processor, heat-sensing cable 60 m |
| Access Control Controller | Card-based, with door magnetic detection and timeout alarm |
| Inductive Card Reader | Explosion-proof, Exdb IIB T4 Gb, contactless IC card |
| Electromagnetic Lock | Holding force ≥ 280 kg, with door status feedback |
| Door Magnetic Switch | Detects door open/close status, switching output |
| Air Conditioner | Cooling capacity 7,200 W, level 2 energy efficiency, cold/warm type, supports -40°C heating |
| Electric Heater | Explosion-proof, 3 kW, 220 V, with temperature control |
| CO₂ Fire Extinguisher | MT7, filling capacity 7 kg, per GB 4351 |
5. Core Functions & Features of Products
- Extreme Cold-Resistant Construction: Rock wool sandwich panel walls (≥ 100 mm) and full-system design withstand ambient temperatures down to -46°C.
- Explosion-Proof Design: All electrical components in hazardous areas are certified Exdb IIB T4, IP65, ensuring safe operation in classified zones.
- Integrated Fire Alarm System: Automatic fire detection and alarm with wall-mounted controller (backup power ≥ 8 h), photoelectric smoke detectors, manual alarm buttons, audible/visual alarms, linear heat detection (60 m cable), and bus isolators for short-circuit protection.
- Intelligent Power Supply: DC 24 V intelligent power box with ≥ 3 h battery backup ensures uninterrupted power for fire and safety systems during outages.
- Reliable Access Control: Explosion-proof card reader, electromagnetic lock (≥ 280 kg holding force), and door magnetic switch with switching output for remote monitoring at the superior station.
- Year-Round Climate Control: Split air conditioner supporting -40°C heating and explosion-proof 3 kW electric heaters maintain indoor temperature ≥ 18°C in winter and ≤ 25°C in summer.
- Comprehensive Lightning & Grounding Protection: Copper grounding plate (300 × 300 × 10 mm) and high-conductivity grounding conductors (≥ 160 mm²) per GB 50303.
- Long Maintenance-Free Operation: Room structure designed for ≥ 10-year maintenance-free service and ≥ 5-year anti-corrosion life.
- Emergency Lighting & Evacuation: Centralized emergency lighting power supply with ≥ 90 min backup duration and evacuation indication complies with safety codes.
- Flexible Cable Management: Removable cover plates and pre-designed cable entry sealing plates allow easy cabling and maintenance access.
6. Core Advantages of The Solution
- Turnkey Integrated Solution: A single-source supply covering the room body, electrical, fire alarm, access control, HVAC, and fire-fighting equipment – fully engineered, installed, and commissioned.
- Designed for Extreme Environments: Built to operate reliably at -46°C with severe wind/sand, seismic, and lightning conditions typical of mid-temperate continental arid regions.
- Strict Standards Compliance: All systems conform to applicable Chinese national standards (GB 50116, GB 50303, GB 4351, SY/T 0319) and the project’s technical specification.
- Explosion-Safe: Exdb IIB T4 certified electrical, fire detection, and access control components installed throughout hazardous areas.
- Factory-Proven Quality: Complete factory assembly, testing, and commissioning before shipment reduces on-site installation time and risks.
- Low Lifecycle Cost: Maintenance-free envelope (≥ 10 years) and anti-corrosion coating (≥ 5 years) minimize long-term operational expenses.
- Clear Scope Management: Well-defined supply boundary – the pressure regulating skid, UPS, network cabinets, video surveillance, SIS/PLC/metering cabinets, and combustible gas alarms are excluded, eliminating ambiguity.
- Fast Deployment: Modular skid-mounted design enables rapid site installation with minimal civil work.
7. Manufacturer Strength Introduction
KITOZER, operated by Guangzhou Lai’an Intelligent System Development Co., Ltd., is a high-tech enterprise founded in 2002, specializing in the design and manufacture of integrated electromechanical equipment rooms, skid-mounted systems, and intelligent control solutions. The company holds ISO 9001 (quality management), ISO 14001 (environmental management), and ISO 45001 (occupational health & safety) certifications. As a manufacturer, KITOZER operates with complete in-house quality inspection procedures, and every unit undergoes comprehensive pre-shipment testing and commissioning to ensure reliable performance in demanding field applications. KITOZER is recognized for delivering high-cost-performance industrial enclosure and skid-mounted solutions to clients across China and international markets.
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1.1 | Skid-Mounted Color Steel Room Main Body | KITOZER-CBG-10036 | Wall: rock wool sandwich color steel plate, insulation ≥ 100 mm, resistant to -46°C | 1 | Set | 31,078.88 | 31,078.88 | KITOZER | Includes roof, walls, and frame |
| 1.2 | Steel Structure Base | KITOZER-JG-10036 | Profile steel welded, integral anti-corrosion, pre-drilled bolt holes / grounding terminals | 1 | Set | 11,099.60 | 11,099.60 | KITOZER | Integrated with room body |
| 1.3 | Door & Window System | KITOZER-MC-01 | Includes 1 anti-theft door, 2 observation windows, sealing IP54 | 1 | Set | 3,773.86 | 3,773.86 | KITOZER | Entrance door with door closer |
| 1.4 | Interior Decoration | KITOZER-ZX-36 | Anti-slip anti-static floor; walls and ceiling leveling treatment | 1 | Set | 6,659.76 | 6,659.76 | KITOZER | Meets safety & environmental standards |
| 1.5 | Painting System | KITOZER-TQ-01 | Sandblasting rust removal; 2 primer coats + 2 topcoats; pipeline safety yellow | 1 | Set | 8,879.68 | 8,879.68 | KITOZER | Anti-corrosion ≥ 5 years; per SY/T 0319 |
| 1.6 | Foundation Embedded Parts | KITOZER-YM-36 | Embedded steel plates, anchor bolts and gaskets | 1 | Set | 1,775.94 | 1,775.94 | KITOZER | For concrete foundation connection |
| 1.7 | Cabinet Bracket & Movable Cover Plate | KITOZER-JGZJ | Channel steel [80 × 43 × 5 Q235B galvanized; movable cover plate; fire/water/dust-proof | 1 | Set | 3,107.89 | 3,107.89 | KITOZER | Per spec 4.2.1(5)(7) |
| 1.8 | Stainless Steel Nameplate | KITOZER-MP | Permanent anti-corrosion, bolt-fixed, includes equipment information | 1 | Piece | 355.19 | 355.19 | KITOZER | Per spec Chapter 8 |
| 4.1 | Power Distribution Box (AP03) | Explosion-proof type | Wall-mounted, Exdb IIB T4, IP65 | 1 | Panel | 5,327.81 | 5,327.81 | Delixi/CHNT | Main power distribution in skid |
| 4.2 | Analog Signal Junction Box (JE) | Explosion-proof type | Exdb IIB T4, IP65, 15% terminal reserve | 4 | Panel | 1,109.96 | 4,439.84 | KITOZER | 1 per pressure regulating skid |
| 4.3 | Switching Signal Junction Box (JD) | Explosion-proof type | Exdb IIB T4, IP65, 15% terminal reserve | 4 | Panel | 1,109.96 | 4,439.84 | KITOZER | 1 per pressure regulating skid |
| 4.4 | Skid Lighting System | Explosion-proof LED | Exdb IIB T4, IP65, ≥ 20 W | 1 | Set | 1,553.94 | 1,553.94 | Ocean King/OK Marine | Includes switches and cables |
| 4.5 | Lightning Protection & Grounding System | KITOZER-JD | Includes grounding copper busbar, grounding wire, terminals | 1 | Set | 3,551.87 | 3,551.87 | KITOZER | Per GB 50303 |
| 4.6 | Grounding Copper Busbar/Plate Upgrade | KITOZER-JDUP | Grounding copper plate 300 × 300 × 10 mm; grounding conductor ≥ 160 mm² | 1 | Item | 1,109.96 | 1,109.96 | KITOZER | Per spec 4.2.1(10) |
| 4.7 | Cables & Cable Tray | Qifan/Far East | Power/signal cables, galvanized steel conduit, explosion-proof glands | 1 | Batch | 7,991.71 | 7,991.71 | Qifan/Far East | For all skid internal connections |
| 4.8 | Low-Voltage Switchgear & Control Equipment | Delixi/CHNT | Contactors, relays, terminal blocks, etc. | 1 | Batch | 1,687.14 | 1,687.14 | Delixi/CHNT | For pressure regulating skid control |
| 4.9 | Electrical Installation & Commissioning | KITOZER-DZ | All electrical installation, wiring, loop and grounding tests | 1 | Item | 1,109.96 | 1,109.96 | KITOZER | Overall commissioning passed |
| 4.10 | Emergency Lighting Centralized Power Supply & Evacuation Indication | KITOZER-YJZM | Includes centralized power supply, evacuation indicator lights, backup lighting; duration ≥ 90 min | 1 | Set | 1,775.94 | 1,775.94 | KITOZER | Per spec 4.2.2(8) |
| 4.11 | Cable Entry Sealing Cover Plate | KITOZER-JCK | 600 × 200 mm, with movable cover plate and sealing measures | 2 | Location | 443.98 | 887.97 | KITOZER | Per spec 4.2.1(5) |
| 5.1 | Fire Alarm Controller | Fanhai Sanjiang/ThaiOn | Wall-mounted, with audible/visual alarm, backup power ≥ 8 h | 1 | Unit | 1,687.14 | 1,687.14 | Fanhai Sanjiang | Installed inside skid room |
| 5.2 | Point-Type Photoelectric Smoke Detector | Explosion-proof type | Exdb IIB T4, IP65 | 3 | Piece | 244.19 | 732.58 | Fanhai Sanjiang | Evenly arranged in room |
| 5.3 | Manual Fire Alarm Button | Explosion-proof type | Exdb IIB T4, IP65, with telephone jack | 1 | Piece | 168.71 | 168.71 | Fanhai Sanjiang | Installed beside entrance door |
| 5.4 | Fire Audible & Visual Alarm | Explosion-proof type | Exdb IIB T4, IP65, sound pressure level ≥ 85 dB | 1 | Piece | 199.79 | 199.79 | Fanhai Sanjiang | Installed at conspicuous location |
| 5.5 | Alarm System Cables & Auxiliary Materials | Flame-retardant | Includes cables, terminals, conduit, fixing materials | 1 | Batch | 2,095.60 | 2,095.60 | KITOZER | For system connection |
| 5.6 | System Installation & Commissioning | KITOZER-XT | Equipment installation, wiring, linkage and alarm testing | 1 | Item | 1,553.94 | 1,553.94 | KITOZER | Per GB 50116 |
| 5.7 | Intelligent Power Box | Fanhai Sanjiang | DC 24 V, 4 A, built-in battery backup ≥ 3 h | 1 | Unit | 1,331.95 | 1,331.95 | Fanhai Sanjiang | Per spec 4.2.3.A(2) |
| 5.8 | Bus Isolator | Fanhai Sanjiang | Non-polar two-bus, automatic short-circuit isolation | 2 | Piece | 88.80 | 177.59 | Fanhai Sanjiang | Per spec Table 4.2-1 |
| 5.9 | Input/Output Module | Fanhai Sanjiang | Non-polar two-bus, DC 24 V, contact capacity 2 A | 2 | Piece | 133.20 | 266.39 | Fanhai Sanjiang | Per spec Table 4.2-1 |
| 5.10 | Module Box | Fanhai Sanjiang | 6 installation positions, includes box and terminals | 1 | Set | 221.99 | 221.99 | Fanhai Sanjiang | Per spec Table 4.2-1 |
| 5.11 | Cable-Type Linear Heat Detector | Fanhai Sanjiang | Fixed temp 85°C, microprocessor modulator, terminal processor, heat-sensing cable 60 m | 1 | Set | 1,109.96 | 1,109.96 | Fanhai Sanjiang | Per spec Table 4.2-1 |
| 5.12 | Fire Alarm Surge Protector | Domestic premium | Signal bus / power bus surge protection, In ≥ 3 kA | 2 | Piece | 111.00 | 221.99 | KITOZER | Per spec 4.2.3.A(10)(11) |
| 6.1 | Access Control Controller | ZKTeco | Card-based, with door magnetic detection and timeout alarm | 1 | Unit | 976.77 | 976.77 | ZKTeco | Supplied complete with skid |
| 6.2 | Inductive Card Reader | Explosion-proof type | Exdb IIB T4 Gb, contactless IC card | 1 | Unit | 799.17 | 799.17 | ZKTeco | Installed outside entrance door |
| 6.3 | Electromagnetic Lock | Single-door magnetic lock | Holding force ≥ 280 kg, with door status feedback | 1 | Piece | 377.39 | 377.39 | KITOZER | Installed inside entrance door |
| 6.4 | Door Magnetic Switch | Explosion-proof type | Detects door open/close status, switching output | 1 | Set | 168.71 | 168.71 | KITOZER | Remote transmission to superior station |
| 6.5 | Exit Button | Explosion-proof type | Standard type | 1 | Piece | 97.68 | 97.68 | KITOZER | Installed inside entrance door |
| 6.6 | Access Control Cables & Auxiliary Materials | Shielded control cable | Includes cables, terminals, conduit | 1 | Batch | 443.98 | 443.98 | KITOZER | For system connection |
| 6.7 | System Installation & Commissioning | KITOZER-MJ | Equipment installation, wiring, functional testing | 1 | Item | 599.38 | 599.38 | KITOZER | Overall commissioning passed |
| 7.1 | Split Wall-Mounted Air Conditioner | Gree/Midea | Cooling capacity 7,200 W, level 2 energy efficiency, cold/warm type, supports -40°C heating | 1 | Unit | 2,885.99 | 2,885.99 | Gree/Midea | Wall-mounted installation |
| 7.2 | Electric Heater | Explosion-proof type | Power 3 kW, 220 V, with temperature control | 2 | Unit | 799.17 | 1,598.34 | KITOZER | Explosion-proof type |
| 7.3 | Air Conditioner & Heater Installation Accessories | Compatible | Includes bracket, copper pipe, drain pipe, power cables | 1 | Batch | 887.97 | 887.97 | KITOZER | For installation requirements |
| 7.4 | System Installation & Commissioning | KITOZER-HVAC | Equipment installation, wiring, cooling/heating testing | 1 | Item | 1,065.56 | 1,065.56 | KITOZER | Performance test passed |
| 8.1 | Portable CO₂ Fire Extinguisher | MT7 | Filling capacity 7 kg | 2 | Unit | 168.71 | 337.43 | Minshan/Zhe’an | Per GB 4351 |
| 8.2 | Fire Extinguisher Box | Stainless steel | Holds 2 MT7-type extinguishers | 1 | Piece | 106.56 | 106.56 | KITOZER | Installed at skid room entrance |
Total Quotation Price: USD 120,719.34
Fee Summary (per source quotation document):
- Equipment subtotal (as stated in source): USD 136,294.21
- Freight (logistics, collection on delivery): USD 0.00 (paid by buyer directly to logistics company)
- Special VAT invoice tax (10%): USD 13,629.42
- Grand total (including special VAT invoice tax, excluding freight): USD 149,923.63
- Alternative: if a regular invoice is required, tax is 3%: USD 4,088.79; grand total: USD 140,383.01
- Freight is to be collected by the logistics company directly from the buyer.
9. Quotation Terms & Conditions
- Currency: All prices are quoted in USD (converted from CNY at the fixed rate of 1 USD = 6.7570 CNY).
- Incoterms: Prices are on an EXW (Ex-Works) Guangzhou, China basis, unless otherwise negotiated.
- Payment Terms: 30% deposit upon order confirmation and 70% balance before shipment (terms negotiable).
- Lead Time: 15–30 working days depending on configuration and order quantity.
- Validity: This quotation is valid for 30 days from the date of issue.
- Taxes & Invoices: Prices exclude tax; a special VAT invoice attracts a 10% surcharge, while a regular invoice attracts a 3% surcharge.
- Freight & Packing: Packing and shipping costs are quoted separately; freight is typically collected by the logistics carrier directly from the buyer unless otherwise agreed.
- Scope Exclusions: The pressure regulating skid itself, UPS, network cabinets, video surveillance system, SIS/PLC/metering cabinets, and combustible gas alarm detectors are excluded from this quotation, as specified in the clarification document.
10. After-sales Service Description
- Warranty: 12–24 months warranty on products (warranty period varies by product category), starting from the date of delivery.
- Technical Support: Lifetime remote technical support provided by the KITOZER engineering team.
- Spare Parts: Long-term availability of spare parts for all supplied equipment.
- On-Site Services: Remote troubleshooting as the first-line response; on-site service visits are available upon request.
- Response Time: All service inquiries receive a response within 24 hours.
11. Contact & Order Information
To place an order or request further technical clarification, please contact the KITOZER sales team:
- Official Website: www.gdlain.com
- Brand: KITOZER
- Company: Guangzhou Lai’an Intelligent System Development Co., Ltd.
- Contact Person: Mr. Zhou
- Phone / WeChat: +86 139 2228 9957
- Address: Chaotian Zone, Zhongrun Industrial Park, No. 5 Huashan Road, Shi Lou Town, Panyu District, Guangzhou, China
All inquiries and order requests received via the official website or direct contact will be responded to within 24 hours.
12. SEO Keywords & Tags
KITOZER quotation, pressure regulating skid quotation, skid-mounted equipment room price list, pressure regulating skid price, skid-mounted room factory price, explosion-proof skid room quotation, rock wool sandwich panel equipment room cost, fire alarm system skid room price, access control skid quotation, HVAC skid-mounted room cost, KITOZER turnkey skid quotation, industrial skid enclosure price, Exdb IIB T4 explosion-proof quotation, skid-mounted equipment room manufacturer, China skid room supplier price