KITOZER
KITOZER

KITOZER Pressure Transmitter 0-10 Bar For Water System

The KITOZER 0 to 10 bar pressure transmitter converts water system pressure into a 4 to 20 mA electrical signal for the BMS or PLC. It is used to monitor chilled water, condenser water, and domestic water pressure at pumps, headers, and farthest loops. The robust ceramic or stainless steel diaphragm handles water with mild chemicals and provides long term stability with minimal drift.

Pressure transmitters are essential for VFD pump control, leak detection, and filter status monitoring. The 4 to 20 mA signal is industry standard for long distance analog transmission, resisting electrical noise from VFDs and contactors. Two wire loop powered design simplifies wiring.

Product Overview

The transmitter is a compact stainless steel body with G1/2 or NPT1/2 process connection and M12 or cable gland electrical connection. It is available with 4 to 20 mA two wire, 0 to 10 V, or Modbus RTU output. A LED indicator shows power and signal health. The sensor is compensated for temperature effects from minus 10 C to 80 C ambient.

The sensing element is a piezoresistive silicon chip isolated from the process by a stainless steel diaphragm. A fill fluid transfers pressure to the chip. The electronics module amplifies and conditions the signal. The housing is IP65 rated for plant room and outdoor use.

Technical Specifications

Measuring range 0 to 10 bar. Accuracy plus or minus 0.5 percent FS. Output 4 to 20 mA two wire. Supply voltage 12 to 36 V DC. Process connection G1/2. Diaphragm material stainless 316L. Overpressure 2x FS. Protection IP65. Weight 180 g. CE certified, 2 year warranty.

Application Scenarios

Install transmitters on pump discharge headers, suction headers, farthest loop differential pressure taps, and chiller evaporator or condenser pressure ports. They provide feedback for VFD pump control, leak detection, and filter dirty condition monitoring. In HVAC systems, differential pressure across filters and coils triggers maintenance alerts. In water treatment, transmitters monitor feed pressure and tank level indirectly.

In data centers, transmitters monitor chilled water supply pressure to ensure pumps deliver flow. In HVAC, they provide differential pressure setpoint for VFD pump control. In boilers, they monitor feed water pressure. In fire systems, they supervise sprinkler loop pressure. The 0 to 10 bar range covers most HVAC and domestic water applications.

Advantages and Features

4 to 20 mA signal resists noise over long cable runs. The 316L diaphragm resists corrosion in treated water. Compact size fits tight pump skids. Temperature compensated output maintains accuracy across seasons. The transmitter is lightning protected. Zero and span can be adjusted via potentiometer or remote command. Multiple output options match different BMS I/O modules.

Compared with mechanical pressure gauges, the transmitter provides continuous remote monitoring and alarm capability. Compared with pressure switches, it offers proportional feedback for VFD control. The 316L diaphragm handles glycol and corrosion inhibitor solutions. The compact size fits crowded pump skids.

Installation and Maintenance

Mount the transmitter with a 5 way manifold or isolation valve for service without draining the loop. Use a siphon tube for hot water applications. Avoid installing at high point where air can collect. Wire shielded cable, grounding at BMS end only.

Calibrate annually against a dead weight tester. Replace the transmitter if drift exceeds 1 percent FS. Bleed air through the vent screw during commissioning. Keep the process connection tight to prevent leaks.

Differential pressure transmitters, which measure the difference between supply and return pressure, are widely used across HVAC filters, coils, and pump differential pressure setpoints. These units use two pressure ports and output a 4 to 20 mA signal proportional to the difference. The 0 to 10 bar gauge transmitter described here is the most common for pump and header monitoring. For vacuum or absolute pressure applications, KITOZER offers alternative ranges. All transmitters are factory calibrated and supplied with a calibration certificate traceable to national standards.

KITOZER pressure transmitters are available in ranges from 0 to 1 bar up to 0 to 600 bar, with gauge, absolute, and differential options. The 316L stainless steel diaphragm handles glycol, chilled water, and treated condenser water. The electronics are lightning and surge protected. Output options include 4 to 20 mA two wire, 0 to 10 V, and Modbus RTU. All units are factory calibrated and supplied with a calibration certificate.

KITOZER pressure transmitters are CE marked and EMC certified. The compact 180 g body fits tight pump skids. The M12 electrical connector or cable gland provides secure wiring. A 5 way manifold accessory allows isolation and calibration without system shutdown. All transmitters are factory calibrated with a traceable certificate. A 2 year warranty covers electronics and sensing elements.

Price

From $65 per transmitter. Contact KITOZER for differential pressure and absolute pressure versions.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top