KITOZER Pressure Transmitter 0-10 Bar For Water System

The KITOZER 0 to 10 bar pressure transmitter converts water system pressure into a 4 to 20 mA electrical signal for the BMS or PLC. It is used to monitor chilled water, condenser water, and domestic water pressure at pumps, headers, and farthest loops. The robust ceramic or stainless steel diaphragm handles water with mild chemicals and provides long term stability with minimal drift.

Product Overview

The transmitter is a compact stainless steel body with G1/2 or NPT1/2 process connection and M12 or cable gland electrical connection. It is available with 4 to 20 mA two wire, 0 to 10 V, or Modbus RTU output. A LED indicator shows power and signal health. The sensor is compensated for temperature effects from minus 10 C to 80 C ambient.

Technical Specifications

Measuring range 0 to 10 bar. Accuracy plus or minus 0.5 percent FS. Output 4 to 20 mA two wire. Supply voltage 12 to 36 V DC. Process connection G1/2. Diaphragm material stainless 316L. Overpressure 2x FS. Protection IP65. Weight 180 g. CE certified, 2 year warranty.

Application Scenarios

Install transmitters on pump discharge headers, suction headers, farthest loop differential pressure taps, and chiller evaporator or condenser pressure ports. They provide feedback for VFD pump control, leak detection, and filter dirty condition monitoring. In HVAC systems, differential pressure across filters and coils triggers maintenance alerts. In water treatment, transmitters monitor feed pressure and tank level indirectly.

Advantages and Features

4 to 20 mA signal resists noise over long cable runs. The 316L diaphragm resists corrosion in treated water. Compact size fits tight pump skids. Temperature compensated output maintains accuracy across seasons. The transmitter is lightning protected. Zero and span can be adjusted via potentiometer or remote command. Multiple output options match different BMS I/O modules.

Installation and Maintenance

Mount the transmitter with a 5 way manifold or isolation valve for service without draining the loop. Use a siphon tube for hot water applications. Avoid installing at high point where air can collect. Wire shielded cable, grounding at BMS end only. Calibrate annually against a dead weight tester. Replace the transmitter if drift exceeds 1 percent FS. Bleed air through the vent screw during commissioning.

Price

From $65 per transmitter. Contact KITOZER for differential pressure and absolute pressure versions.