Table of Contents
ToggleProduct Overview
The KITOZER 0 to 10 bar pressure transmitter measures gauge pressure of liquids and gases in hydraulic, pneumatic, water, and compressed air systems. A stainless steel sensor cell and welded housing provide good corrosion resistance for process water, light oils, and compressed air. The 4 to 20 mA two-wire output feeds PLC analog cards directly, and the device carries surge and reverse polarity protection to survive installation errors and electrical transients. The compact M20x1.5 process connection fits standard industrial mounting holes, and the cable gland version allows flexible wiring orientation at the transmitter.
Technical Specifications
Range 0 to 10 bar gauge, overpressure 3x, burst pressure 5x. Accuracy +/-0.5% FS, option +/-0.25%. Output 4 to 20 mA two-wire, power 9 to 30 VDC. Wetted parts: 316L stainless steel, NBR or FKM seal. Process connection M20x1.5, G1/2, NPT1/2 option. Protection IP65, operating temperature -30 to 85 C. CE, KITOZER, 3 year warranty.
Applications
This pressure transmitter is widely used in pump stations, hydraulic power units, compressor skids, reverse osmosis systems, HVAC chilled water loops, and pneumatic control panels. In water treatment, it monitors filter inlet and outlet pressure to trigger backwash when the differential crosses the threshold. In hydraulic presses, it confirms clamping pressure before the press cycle starts, providing interlocking safety signals. On compressor skids, the transmitter reports main line pressure to the PLC for load and unload control. The 316L diaphragm version handles mildly aggressive media such as condensate and weak cleaning solutions.
Advantages
The KITOZER pressure transmitter combines a thin-film stainless sensor with signal conditioning electronics in a compact sealed housing, delivering stable readings across temperature shifts without field recalibration. The 4 to 20 mA output is immune to electrical noise in plants with VFDs, and the 3x overpressure rating protects the cell from water hammer during pump start-stop cycles. A lightning and surge protection option is available for outdoor installations on pump stations. The wide choice of process connections and electrical outputs simplifies substitution of older transmitters without re-drilling the manifold.
Installation and Maintenance
Mount the transmitter with a shut-off valve and a pulsation damper when measuring pump discharge pressure, to isolate the cell for service and smooth fast pressure spikes. For steam applications, install a siphon loop so hot condensate reaches the diaphragm instead of live steam. Torque the process connection to the recommended value to avoid stress on the cell, and use a wrench on the flats rather than on the housing. Check zero offset annually by venting the process and comparing the 4 mA reading. If the reading drifts, inspect the diaphragm for clogging or crystallization, and clean with a soft brush and compatible solvent. Keep the cable gland tightened to maintain the IP rating.
Working Principle
The sensor element is a thin-film stainless steel diaphragm with piezoresistive strain gauges deposited in a Wheatstone bridge arrangement. Process pressure deflects the diaphragm, changing the bridge resistance proportionally to the applied pressure. The excitation voltage and bridge output are conditioned by an ASIC that amplifies, linearizes, and temperature-compensates the signal across the operating range. The conditioned voltage is converted to a 4 to 20 mA loop current, where 4 mA represents the lower range and 20 mA the upper range. The loop is powered by the same two wires, so no separate transmitter supply is needed.
Selection Guide
Choose the gauge pressure version for vented tank and pump applications. For sealed or absolute pressure measurements, select the sealed gauge or absolute option. For aggressive chemicals, choose the 316L diaphragm with FKM seal, or the Hastelloy option for chloride services. For steam or hot oil, select the high temperature version with a heat sink. For outdoor installations, choose the surge-protected variant and a weatherproof connector. Order the local LCD version if operators need to read pressure at the transmitter itself.
Each transmitter ships with a quick-start guide, a gasket, and a calibration sticker. Optional accessories include a siphon loop, a pulsation damper, a needle valve manifold, and a digital calibrator. KITOZER provides pre-configured units for common ranges such as 0 to 10 bar and 0 to 16 bar, which arrive ready to install. Spare transmitters are stocked regionally, and a 3 year warranty covers manufacturing defects. Technical support is available by email and WeChat during working hours, and custom ranges or special output signals can be ordered with a short lead time. Every KITOZER transmitter is factory calibrated against traceable standards before shipment, and a calibration certificate is included with each unit. The devices undergo temperature cycle, EMC immunity, and IP rating testing during production. The installation manual includes wiring diagrams for common PLC analog input cards, and engineers can request a loop check sheet for commissioning. NIST-traceable calibration is available on request for regulated industries.
Price
From $45/pc. Contact +86 13922289957 for pressure transmitter quotation and custom ranges.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com