KITOZER
KITOZER

KITOZER Pressurization Fan: 15000m3/h Axial Smoke Exhaust

Product Overview

The KITOZER 15000 cubic meters per hour axial flow fan is used as the positive pressure supply fan for stairwells and front rooms in high-rise buildings, maintaining a slight overpressure of 25 to 30 Pascals to keep smoke out of evacuation paths during a fire. The fan is rated for continuous operation at 280 degrees Celsius for 30 minutes, satisfying the fire smoke control requirements of GB 51251. The galvanized steel housing and aluminum impeller combine light weight with corrosion resistance, and the motor is mounted outside the airflow stream for easier maintenance.

Technical Specifications

Air flow 15000 m3/h, static pressure 600 Pa, motor power 4 kW, speed 1450 rpm, three phase 380V, impeller diameter 560 mm, housing galvanized steel 2 mm, impeller aluminum alloy, transmission belt drive, noise level 78 dB(A) at 1.5 m, mounting horizontal or vertical, connection spigot DN630, thermal rating 280 degrees Celsius 30 minutes, IP55 motor, Class F insulation, CCCF certified, GB 15930. Weight 95 kg.

Application Scenarios

This fan supplies fresh air to enclosed stairwells, smoke-proof front rooms, and elevator lobbies in office towers, hotels, hospitals, shopping malls, and residential buildings above 50 meters. It starts automatically when the fire alarm panel detects smoke on any floor, and the variable inlet vane or bypass damper adjusts airflow to maintain overpressure as stairwell doors open. KITOZER also supplies matching smoke exhaust fans for the ceiling cavity and car park, and the complete smoke control ductwork and damper package.

Key Advantages

The 280 degrees Celsius rating means the fan continues running even if hot smoke is drawn into the shaft, which is essential for protecting evacuation paths. The belt drive isolates the motor from the hot airstream, extending motor life and allowing easy sheave changes. The aluminum impeller is lightweight and dynamically balanced, reducing vibration on the roof support structure. KITOZER provides factory performance test certificates for airflow and pressure, so the commissioning engineer can verify the installed system against design without a full airflow test.

Installation and Maintenance Recommendations

Mount the fan on spring isolators on the roof or mechanical floor, and connect the duct with flexible canvas connectors to avoid transmitting vibration. Keep fan access panels facing the maintenance walkway. Inspect belt tension quarterly and replace belts every 2 years. Lubricate motor bearings annually, and verify the fire alarm start circuit annually by activating the fan from the fire control room. Record current draw and airflow pressure at each service visit, and compare against the factory curve to detect impeller fouling.

Price

From $880 per fan. Contact +86 13922289957 for pressurization fan pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top