The KITOZER primary loop piping kit is a pre-fabricated stainless steel assembly that connects facility chillers or dry coolers to CDU heat exchangers, isolating the IT-side secondary loop from the building water. The kit includes supply and return headers, isolation ball valves, Y-strainers, pressure relief valves, pressure gauges, vent and drain points, and flange connections sized to match the CDU. Pre-fabrication reduces on-site welding and pressure testing, and each kit is engineered to the project layout with custom lengths, elbows, and tees.
The primary loop kit is designed to connect the chiller plant to one or more CDUs, providing isolation, filtration, and pressure protection between the two. Supply and return headers run along the plant room wall, with branch connections to each CDU. Y-strainers protect the CDU heat exchanger from pipe debris. Pressure relief valves protect against thermal expansion over-pressure. Vent and drain points allow filling and draining the loop during commissioning and maintenance.
Technical Specifications
Pipe: 316L stainless steel, seamless, DN50 to DN200, design pressure 10 bar. Isolation valves: ball valve PN16, DN50 to DN200. Y-strainer: 316L stainless, 20 mesh. Pressure relief valve: set 6 bar, DN25. Gauges: 0 to 10 bar, glycerin filled. Flanges: PN16, 316L. Insulation: 19 mm closed-cell elastomer, 32 mm on cold pipes. Pressure tested at 15 bar for 30 minutes before shipment. KITOZER, CE, 10 year material warranty, 2 year valve warranty.
The kit includes supply and return headers sized to the CDU capacity, isolation ball valves at each branch, Y-strainers with blowdown valves, pressure relief valves set at 6 bar, glycerin-filled pressure gauges, vent and drain points, and PN16 flanges at each CDU connection. Closed-cell elastomer insulation prevents condensation on cold pipes. The kit is factory pressure-tested to 15 bar for 30 minutes and serialized.
Applications
The primary loop kit serves any liquid-cooled data hall where facility chilled water or a dry cooler supplies the CDU. Typical deployments include HPC data centers, GPU training halls, immersion cooling bays, and industrial process cooling plants. The kit also supports retrofit projects where a new CDU row is added to an existing chiller plant, with custom headers sized to the available chiller capacity.
Common installations include HPC data centers, GPU training halls, immersion cooling bays, and industrial process cooling plants. The kit also supports retrofit projects where a new CDU row is added to an existing chiller plant. Custom headers are sized to the available chiller capacity and CDU count. Pre-fabrication reduces on-site welding and commissioning time.
Key Advantages
Pre-fabricated sections cut on-site welding by up to 70 percent. Integrated Y-strainer protects the CDU heat exchanger from pipe debris. Isolation valves allow individual CDU service without loop shutdown. Pressure relief valve protects against thermal expansion over-pressure. Closed-cell insulation prevents condensation on cold pipes. Factory pressure-tested to 15 bar. Custom lengths and bends match the project layout exactly.
Pre-fabricated sections cut on-site welding. Y-strainer protects HX. Isolation valves allow CDU service. PRV protects against over-pressure. Closed-cell insulation prevents condensation. Factory pressure-tested. Custom lengths match layout.
Installation and Maintenance
Route the primary loop through the plant room or overhead tray using pipe supports every 2 m. Connect to chiller and CDU flanges with PN16 gaskets. Pressure-test the loop at 1.5 times working pressure before filling. Monthly: inspect flange joints, gauges, and insulation. Quarterly: clean Y-strainer basket. Annually: test pressure relief valve and inspect flange gaskets. The pipe itself requires no internal maintenance.
Commissioning includes pressure test at 1.5 times working pressure, leak check at each flange, and PRV lift test. After handover, baseline supply and return pressure. Recommended on-site spares: one PN16 gasket set, one Y-strainer basket, one PRV, and one gauge. The pipe itself requires no internal maintenance.
Typical Configuration
A 100 kW CDU primary loop uses DN50 supply and return headers with one isolation valve, one Y-strainer, one PRV, and one pressure gauge per CDU branch. For a row with two CDUs, the kit includes two branch connections, two isolation valves, and two Y-strainers. The main header runs from the chiller plant to the row, with flanged ends at each CDU.
Design Notes
The primary loop kit is engineered to ASME B31.9 building services piping standards, with welded 316L stainless and PN16 flanged connections. All welds are internally purged with argon to prevent oxidation and improve corrosion resistance. The Y-strainer uses 20 mesh screen sized to protect the CDU plate heat exchanger from debris larger than 0.8 mm. Pressure relief valves are set at 6 bar, below the CDU heat exchanger design pressure of 10 bar, providing a protective margin. Vent points are installed at every high point to purge air during filling, and drain points at every low point for complete drainage during maintenance.