The KITOZER DN65 proportional integral control valve modulates chilled water or hot water flow to air handling unit coils and fan coil units based on room or duct temperature signals. The electric actuator accepts 0 to 10 V or 4 to 20 mA control signal from the building management system, providing precise flow control proportional to load. The valve and actuator are matched to optimize coil performance and reduce energy waste from over conditioning.
Table of Contents
ToggleProduct Overview
The valve body is a bronze or stainless steel globe pattern with equal percentage flow characteristic. The electric actuator is non fail safe or spring return, with 24 V AC power and 0 to 10 V control signal. Position feedback 2 to 10 V is standard. The valve is pressure rated PN16 and suitable for water and glycol mixtures up to 120 C. A visual position indicator and manual override lever are included.
Technical Specifications
Nominal size DN65. Kv value 25 m3 per h. Control signal 0 to 10 V or 4 to 20 mA. Power supply 24 V AC. Actuator running time 30 seconds for full stroke. Leakage class ANSI FCI 70-2 Class IV. Body material cast brass or stainless steel, trim stainless 304. Working pressure 16 bar. Weight 4.5 kg. CE certified, 2 year warranty.
Application Scenarios
This valve is installed on cooling coil and heating coil branches in air handling units, variable air volume boxes, and fan coil units. It is also used on reheat coils, mixing loops, and process temperature control. The proportional control characteristic provides stable room temperature under varying load conditions, improving occupant comfort and reducing energy consumption. The valve is commonly integrated into BMS with PID control loops.
Advantages and Features
Equal percentage flow characteristic compensates coil non linearity for stable control. The actuator includes manual override for commissioning and emergency operation. Position feedback allows the BMS to monitor valve travel and detect jamming. Spring return option fails open or closed on power loss for safety critical applications. The compact body fits tight mechanical space. Low power consumption reduces control panel electrical load.
Installation and Maintenance
Install the valve with flow direction matching the body arrow. Mount the actuator upright to prevent water ingress. Use isolation valves and drain ports for service. Commissioning includes calibrating control signal, checking stroke, and tuning PID loop. Annual inspection includes actuator linkage condition, O ring integrity, and seal tightness. Rebuild the valve with replacement seal kit after 5 years of service. Never apply power to the actuator while the valve is disassembled.
Price
From $285 per valve with actuator. Contact KITOZER for Cv selection based on coil data.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com