The KITOZER PT1000 duct temperature sensor provides accurate air temperature measurement in air handling units, ductwork, and clean rooms. The sensor element is a class A PT1000 platinum resistor with 1000 ohm at 0 C, housed in a stainless steel probe and plastic enclosure. It connects directly to building management systems or PLC analog inputs, enabling precise temperature control for VAV boxes, reheat coils, and supply air temperature reset.
Table of Contents
ToggleProduct Overview
The sensor includes a 75 mm or 150 mm stainless steel probe, a plastic wall or duct mount enclosure with cable gland, and a 2 meter shielded cable. Optional versions transmit 4 to 20 mA or 0 to 10 V signal for longer distance runs. The probe tip is formed to improve response time below 30 seconds. A weatherproof version is available for outdoor air measurement.
Technical Specifications
Sensing element PT1000 class A, IEC 60751. Measuring range minus 50 C to plus 100 C. Accuracy plus or minus 0.3 C at 0 C. Probe material stainless 304, length 150 mm. Enclosure ABS plastic, IP54. Cable 2 x 0.5 mm2 shielded, 2 m. Operating humidity 5 to 95 percent RH non condensing. CE certified, 2 year warranty.
Application Scenarios
Install these sensors on supply air ducts, return air ducts, outdoor air intake, and room wall boxes. They are used for coil leaving air temperature, mixed air temperature, and free cooling air side monitoring. In data centers, sensors measure server inlet temperature at rack level. They are also used in refrigerated display cases and clean room environmental monitoring.
Advantages and Features
Class A accuracy ensures tight control loop performance. PT1000 output is compatible with most BMS analog modules. The stainless probe resists corrosion in humid ducts. Fast response time detects temperature changes quickly. The enclosure design allows easy wiring with screw terminals. Shielded cable reduces electrical noise from VFDs. Multiple sensors can be paralleled on the same BMS input if configured correctly.
Installation and Maintenance
Drill a 6 to 8 mm hole in the duct, insert the probe to mid duct, and seal with the included flange plate. Mount the enclosure clear of water condensation paths. Wire to BMS analog input using shielded cable, grounding shield at one end only. Calibrate annually by comparing against a certified reference thermometer in a stirred bath. Replace the sensor if reading deviates more than 0.5 C from reference.
Price
From $28 per sensor. Contact KITOZER for 4 to 20 mA transmitter version.