The KITOZER PT1000 duct temperature sensor provides accurate air temperature measurement in air handling units, ductwork, and clean rooms. The sensor element is a class A PT1000 platinum resistor with 1000 ohm at 0 C, housed in a stainless steel probe and plastic enclosure. It connects directly to building management systems or PLC analog inputs, enabling precise temperature control for VAV boxes, reheat coils, and supply air temperature reset.
PT1000 sensors are preferred over NTC thermistors in commercial HVAC because they offer better long term stability and interchangeability. The PT1000 standard defines a precise resistance temperature relationship, allowing sensors to be replaced without recalibration. Class A accuracy meets the tight control requirements of modern variable air volume systems.
Table of Contents
ToggleProduct Overview
The sensor includes a 75 mm or 150 mm stainless steel probe, a plastic wall or duct mount enclosure with cable gland, and a 2 meter shielded cable. Optional versions transmit 4 to 20 mA or 0 to 10 V signal for longer distance runs. The probe tip is formed to improve response time below 30 seconds. A weatherproof version is available for outdoor air measurement.
The enclosure has screw terminals for easy field wiring. The cable gland provides strain relief and IP54 protection. The probe is available in lengths from 75 mm to 300 mm to match duct wall thickness. The sensor element is fully encapsulated to protect against moisture and vibration.
Technical Specifications
Sensing element PT1000 class A, IEC 60751. Measuring range minus 50 C to plus 100 C. Accuracy plus or minus 0.3 C at 0 C. Probe material stainless 304, length 150 mm. Enclosure ABS plastic, IP54. Cable 2 x 0.5 mm2 shielded, 2 m. Operating humidity 5 to 95 percent RH non condensing. CE certified, 2 year warranty.
Application Scenarios
Install these sensors on supply air ducts, return air ducts, outdoor air intake, and room wall boxes. They are used for coil leaving air temperature, mixed air temperature, and free cooling air side monitoring. In data centers, sensors measure server inlet temperature at rack level. They are also used in refrigerated display cases and clean room environmental monitoring.
In offices, sensors modulate VAV boxes and reheat coils. In hospitals, they monitor surgical suite temperature. In labs, they control incubators and chamber rooms. In data centers, they provide supply air temperature reset signals to chillers. Multiple sensors can be wired in parallel for average duct temperature.
Advantages and Features
Class A accuracy ensures tight control loop performance. PT1000 output is compatible with most BMS analog modules. The stainless probe resists corrosion in humid ducts. Fast response time detects temperature changes quickly. The enclosure design allows easy wiring with screw terminals. Shielded cable reduces electrical noise from VFDs. Multiple sensors can be paralleled on the same BMS input if configured correctly.
Compared with thermocouples, PT1000 sensors do not require cold junction compensation and provide better accuracy at low temperatures. Compared with NTC sensors, PT1000 is fully interchangeable. The stainless probe withstands cleaning during duct maintenance. The plastic enclosure is lightweight and non corrosive.
Installation and Maintenance
Drill a 6 to 8 mm hole in the duct, insert the probe to mid duct, and seal with the included flange plate. Mount the enclosure clear of water condensation paths. Wire to BMS analog input using shielded cable, grounding shield at one end only.
Calibrate annually by comparing against a certified reference thermometer in a stirred bath. Replace the sensor if reading deviates more than 0.5 C from reference. Keep the probe tip clean of dust and mold. Avoid bending the probe, which can damage the element.
PT1000 sensors are available with 2, 3, or 4 wire configurations. The 3 wire version compensates for lead resistance in long cable runs, which is essential when sensors are located far from the BMS panel. The 4 wire version offers the highest accuracy for laboratory reference use. KITOZER supplies 3 wire as standard for HVAC. The sensor can be calibrated in place by the BMS using offset and span adjustments, avoiding physical removal. The stainless probe is compatible with chilled water, hot water, and glycol loops when ordered as an immersion well version.
Price
From $28 per sensor. Contact KITOZER for 4 to 20 mA transmitter version.