The KITOZER Pt1000 temperature sensor is a digital RTD probe designed for cold storage, refrigerated transport, pharmaceutical cold chain, and food warehouse monitoring where accurate, drift-resistant temperature data is required for compliance. The Pt1000 element offers higher resolution than Pt100 and is paired with a 16-bit ADC and RS485 Modbus interface, eliminating the signal loss that affects analog sensors over long cable runs. Each probe is factory calibrated and can be installed directly into a cold room wall or suspended from a rack to monitor product temperature.
For cold chain applications, the sensor supports a wide temperature range from -80 to +150 C, covering both standard chilled storage (2 to 8 C) and deep frozen storage (-25 to -80 C). The RS485 bus allows up to 64 sensors to share a single twisted pair, making it practical to deploy probes at multiple positions in a large warehouse without running separate wires to a central logger. Data can be logged locally by a KITOZER monitoring host or streamed to a cloud platform for real-time compliance dashboards.
Table of Contents
ToggleProduct Overview
The sensor body is a stainless steel 304 probe with a waterproof IP68 junction box. A 5-meter shielded cable is standard, with longer lengths available. The Modbus address can be configured through software, and the sensor automatically reports temperature at a configurable interval. An optional local display version shows readings on a small LCD mounted on the junction box, allowing warehouse staff to verify temperature without opening a monitoring software.
Technical Specifications
Sensing element: Pt1000 Class B. Measurement range: -80 to +150 C. Accuracy: plus or minus 0.2 C at -40 to +80 C, plus or minus 0.5 C across full range. Resolution: 0.01 C. Response time: 10 seconds in moving air. Interface: RS485 Modbus RTU, baud 9600 to 115200, address 1 to 247. Power: 9 to 30 VDC, typical 10 mA. Cable: 5 meter shielded PVC, IP68 junction box. Probe diameter: 5 mm, length 50 mm. Enclosure rating: IP68. Operating temperature: -80 to +150 C at probe, -40 to +80 C at junction box. Certifications: CE, RoHS. KITOZER warranty: 2 years, calibration certificate included.
Application Scenarios
Typical deployments include pharmaceutical cold rooms at 2 to 8 C, vaccine storage, frozen food warehouses at -25 C, ultra-low freezers for biological samples, refrigerated truck trailers, and wine cellars. In a pharmaceutical warehouse, multiple probes are placed near product pallets, at doorways, and at the evaporator outlet, giving quality assurance staff a complete temperature map of the cold room. The data logs can be exported as part of GSP or GDP compliance reports.
Advantages and Features
The digital Modbus output removes the analog signal degradation that plagues 4 to 20 mA and 0 to 10 V sensors in large warehouses. Because the digitization happens at the probe, the cable run length no longer affects accuracy. The Pt1000 element offers long-term stability with minimal drift, reducing calibration frequency. The IP68 junction box allows installation in washdown areas. KITOZER provides free configuration software and a library of Modbus register maps for common PLC and SCADA platforms.
Installation and Maintenance Advice
Mount probes at product storage height, not near the evaporator outlet, to capture the temperature that products actually experience. For door areas, install a second probe to capture temperature spikes during door opening. Use shielded cable and ground the shield at one end to avoid ground loops. Calibrate annually against a reference Pt100 in a calibration bath, and keep the calibration certificate with the warehouse quality records. Inspect the junction box seal every 6 months, as cold room condensation can degrade cable glands over time.
Typical Deployment Configuration
In a pharmaceutical cold room at 2 to 8 C, KITOZER Pt1000 probes are placed at three to six positions representing different storage zones: near the door, near the evaporator, and at the center of the pallet stack. All probes share an RS485 bus running back to a KITOZER monitoring host, which logs data every minute and uploads it to a cloud compliance platform. The host alarms if temperature deviates by more than 2 C from setpoint for more than 15 minutes, and sends SMS alerts to the quality manager. For vaccine storage at -20 C or below, additional probes are installed in each freezer, and the system generates daily temperature reports that can be printed for regulator audits. The IP68 junction box allows the probes to be wiped down as part of cold room cleaning protocols, and the stainless steel probe resists condensation and frost formation. KITOZER provides a free data export tool that converts logged readings into CSV or PDF compliance reports.
Price
From $55 per unit. Contact +86 13922289957 for cold chain project pricing and compliance report templates.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com