Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

KITOZER Pump VFD Control Cabinet | Horizontal End-Suction Pump Package Price

KITOZER pump VFD control cabinet interior showing variable frequency drives, HMI and circuit breakers on DIN rail
KITOZER pump-duty VFD control cabinet — PID closed-loop, multi-pump alternation, dry-run protection

Water supply and drainage stations rarely run at a fixed flow rate. Demand swings through the day, peak-hour fire duty spikes the system pressure, and running a fixed-speed pump against a throttled valve wastes energy. The KITOZER pump and VFD control package pairs horizontal end-suction centrifugal pumps with dedicated VFD control cabinets that adjust speed in real time to hold pressure or flow, with PID closed-loop regulation, multi-pump alternation and pump-protection logic built in.

KITOZER horizontal end-suction centrifugal water pumps on skid base in a mechanical room
Horizontal end-suction centrifugal pumps with inverter-duty motors, mounted on a common baseplate

What the package covers

This reference configuration is for a 11-pump station (2×22 kW, 3×75 kW, 6×55 kW), each pump paired with its own wall-mounted VFD control cabinet. The cabinet supplies the pump motor with variable-frequency power, reads a pressure transducer on the discharge header, and adjusts pump speed to hold a set pressure — starting pumps in sequence and rotating duty so runtime is balanced.

Reference configuration (EXW Guangzhou, USD)

Figures below are market reference prices, EXW Guangzhou, excluding tax and freight. Package reference total: USD 140,278.

Item KITOZER Model Spec Qty Unit Price (USD)
End-suction pump KZ-ES-P22 22 kW, 120 m³/h @ 35 m, DN125 inlet, inverter-duty motor 2 $5,139
End-suction pump KZ-ES-P75 75 kW, 450 m³/h @ 35 m, DN200 inlet, inverter-duty motor 3 $11,667
End-suction pump KZ-ES-P55 55 kW, 400 m³/h @ 32 m, DN200 inlet, inverter-duty motor 6 $8,889
VFD control cabinet KZ-VFD-22 22 kW pump-duty VFD, PID closed-loop, phase loss / overcurrent / dry-run protection 2 $3,000
VFD control cabinet KZ-VFD-75 75 kW pump-duty VFD, PID closed-loop, multi-pump alternation 3 $4,389
VFD control cabinet KZ-VFD-55 55 kW pump-duty VFD, PID closed-loop 6 $3,750
11+11 $140,278

Why a dedicated pump VFD cabinet matters

A general-purpose VFD bolted to the wall does not know it is driving a pump. The KITOZER pump-duty cabinet pre-loads pump protection: dry-run detection, dead-head and over-pressure shutdown, rapid-stall restart after a power cut, and a sequential start that staggers motor inrush on a shared feeder. An HMI panel shows running current, output frequency and header pressure, and a Modbus/4G option pushes the same data to the BMS or cloud.

FAQ

Can you supply just the VFD cabinets without the pumps? Yes. We build the control panels to pair with customer-supplied pumps; pump curves and motor nameplate data are required for correct VFD sizing.

What protection functions are standard? Input breaker, output reactor, motor overload, over/under voltage, dry-run, over-pressure and communication-failure shutdown; alarm relay outputs to the BMS.

What is the lead time? Typical lead time after technical confirmation and deposit is 20–30 working days; larger powers may extend this.

Contact KITOZER

KITOZER / Guangzhou Laian Intelligent System Development Co., Ltd.
Tel / WeChat: +86 13922289957 · +86 18520668845
WhatsApp: +86 19068534140
Web: www.gdlain.com · www.lain.com.cn
Address: Chaotian Park, Zhongrun Industrial Zone, No.5 Huashan Road, Shilou, Panyu, Guangzhou, China

Technical reference compiled from industry practice; figures are market reference prices for planning, not a formal quotation.

Shopping Cart