The KITOZER 16-string 1000V DC photovoltaic combiner box consolidates multiple PV module string outputs into a single DC feed for the inverter, reducing cable runs and simplifying array wiring. Each string is protected by a dedicated DC fuse and monitored for current, while the combined output is protected by a main DC breaker and surge protection device. This enclosure is a critical balance-of-system component in utility-scale and commercial solar arrays.
Table of Contents
ToggleProduct Overview
KITOZER combiner boxes are fabricated from 2mm thick cold-rolled steel with polyester powder coating, rated IP65 for outdoor rooftop and ground-mount exposure. Inside, positive and negative copper busbars distribute string fuses, and optional string monitoring units measure each string current with 15mA resolution. The box accepts MC4 or custom cable entries via IP68 gland plates. A removable DIN rail allows flexible relay and signal interface installation.
Technical Specifications
Maximum system voltage 1000V DC. 16 string inputs, 15A gPV fuse per string, 10x38mm. Main DC switch 250A 1000V DC load break. DC SPD Type 2, 20kA nominal, 40kA maximum, 1000V DC. Surge counter and remote dry contact. String monitoring optional, 16 channels, 0 to 20A per channel, RS485 Modbus RTU. Enclosure dimensions 600x600x250mm. Operating temperature -35 to +70 degrees Celsius. Insulation tested to 3500V DC for one minute. KITOZER brand, 5-year warranty.
Applications
The combiner box is used in ground-mount solar power plants, rooftop commercial arrays, solar carports, and agrivoltaic systems. It suits installations where string-level monitoring helps detect soiling, shading, or defective modules early. It is also deployed in solar pump stations, telecom base station PV sites, and hybrid PV-diesel mini-grids.
Advantages and Features
Independent gPV fuses prevent cross-string reverse currents that can overheat shaded strings and create fire risk. The string monitoring option allows O&M teams to compare string currents in real time and identify underperforming branches without climbing on the roof. The IP65 enclosure withstands UV, rain, and dust. Copper busbars are tin-plated for corrosion resistance. The box ships pre-wired to terminal blocks, so on-site work is limited to external cable gland connections.
Installation and Maintenance
Mount the box on a wall or stand with the hinged door opening a minimum of 100 degrees. Route DC strings through bottom glands, maintaining bend radius above 5 times cable diameter. Torque all MC4 contacts to 1.5Nm and all busbar studs to 8Nm. Before energizing, perform a continuity test and verify no reverse polarity. Maintenance includes visual inspection of SPD status window every six months, infrared thermography of busbar joints annually, and fuse continuity check after any lightning event. Replace SPD cartridges when the indicator window turns red. Keep a log of string current readings to detect gradual performance degradation.
Price