KITOZER
KITOZER

KITOZER PV Combiner Box 16 Strings 1000V DC

The KITOZER 16-string 1000V DC photovoltaic combiner box consolidates multiple PV module string outputs into a single DC feed for the inverter, reducing cable runs and simplifying array wiring. Each string is protected by a dedicated DC fuse and monitored for current, while the combined output is protected by a main DC breaker and surge protection device. This enclosure is a critical balance-of-system component in utility-scale and commercial solar arrays, and it plays a key role in both plant safety and performance monitoring.

Product Overview

KITOZER combiner boxes are fabricated from 2mm thick cold-rolled steel with polyester powder coating, rated IP65 for outdoor rooftop and ground-mount exposure. Inside, positive and negative tin-plated copper busbars distribute string fuses, and optional string monitoring units measure each string current. The box accepts MC4 or custom cable entries via IP68 gland plates. A removable DIN rail allows flexible relay and signal interface installation. The hinged door opens more than 100 degrees and can be retained with a safety catch for safe servicing.

The internal layout separates the high-current busbar compartment from the low-current monitoring compartment, reducing noise on current measurement signals. Every combiner box is pre-wired at the factory between fuses and busbars, so on-site work is limited to external string and inverter connections. Each unit undergoes a routine dielectric test and a continuity test before shipment, with a test report included in the documentation pack.

Technical Specifications

Maximum system voltage 1000V DC. 16 string inputs, 15A gPV fuse per string, 10x38mm. Main DC switch 250A 1000V DC load break. DC SPD Type 2, 20kA nominal, 40kA maximum, 1000V DC, with remote signal contact. String monitoring optional, 16 channels, 0 to 20A per channel, 15mA resolution, RS485 Modbus RTU. Enclosure dimensions 600x600x250mm. Operating temperature -35 to +70 degrees Celsius. Insulation tested to 3500V DC for one minute. Gland plates accept cables from 4mm2 to 16mm2. KITOZER brand, 5-year warranty.

Applications

The combiner box is used in ground-mount solar power plants, rooftop commercial arrays, solar carports, and agrivoltaic systems. It suits installations where string-level monitoring helps detect soiling, shading, or defective modules early. It is also deployed in solar pump stations, telecom base station PV sites, and hybrid PV-diesel mini-grids where a single robust DC distribution point is required. In rooftop retrofit projects, the combiner box allows the owner to add new strings without upgrading the inverter DC input capacity.

Advantages and Features

Independent gPV fuses prevent cross-string reverse currents that can overheat shaded strings and create fire risk. The string monitoring option allows O&M teams to compare string currents in real time and identify underperforming branches without climbing on the roof. The IP65 enclosure withstands UV, rain, and dust. Copper busbars are tin-plated for corrosion resistance. The box ships pre-wired to terminal blocks, so on-site work is limited to external cable gland connections.

The SPD includes a remote signal contact that reports its status to the site SCADA, so maintenance is triggered only when the SPD has absorbed a surge. The load-break DC switch allows safe isolation of the whole combiner for inverter-side work. The gland plates are drilled in the factory to match the agreed cable schedule, reducing on-site drilling and the risk of water ingress. A grounding boss on the enclosure connects the mounting structure to the PV equipotential bonding.

Installation and Maintenance

Mount the box on a wall or stand with the hinged door opening a minimum of 100 degrees. Route DC strings through bottom glands, maintaining bend radius above 5 times cable diameter. Torque all MC4 contacts to 1.5Nm and all busbar studs to 8Nm. Before energizing, perform a continuity test and verify no reverse polarity. Keep the door locked when work is not in progress, and post warning signs because DC arcs do not self-extinguish like AC arcs.

Maintenance includes visual inspection of SPD status windows every six months, infrared thermography of busbar joints annually, and fuse continuity check after any lightning event. Replace SPD cartridges when the indicator window turns red. Keep a log of string current readings to detect gradual performance degradation, and compare them with the expected production for the season. In dusty environments, clean the enclosure exterior twice a year and inspect the door gasket for brittleness.

Quality and Reliability

Each KITOZER combiner box undergoes a 100 percent factory test that includes dielectric withstand at 3500V DC, continuity of all fuse positions, and functional verification of the SPD remote contact. A test certificate is shipped with the box. The steel enclosure is phosphate treated and powder coated to 80 to 120 micrometers, and the door gasket is made of UV-resistant EPDM to maintain IP65 over decades of outdoor exposure. Fuses, SPDs, and breakers are sourced from recognized brands to ensure consistent long-term performance.

Price

From $890/pc. Contact +86 13922289957 for 16-string combiner box quote and customized string count options from 4 to 24 strings.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart