Table of Contents
ToggleSystem Integration Notes
When designing a cooling system around KITOZER quick couplings, it is important to size the port for the expected flow rate and pressure drop. Undersized couplings increase pumping energy and can cause uneven cooling across the rack. Plan for access clearance around each coupling for hand operation and visual inspection. Color-code supply and return lines at every connection point to eliminate cross-connection during maintenance. For mission-critical loops, carry spare seal cartridges and at least one complete coupling pair on site. KITOZER recommends documenting each coupling location, installation date, and cycle count in the facility maintenance register. When mixing coupling brands, verify poppet profile compatibility before deployment, as not all industry profiles are fully interchangeable. Training maintenance staff on proper engagement and disconnection technique reduces cycle wear and leak incidents.
Best Practices
For best results, KITOZER recommends establishing a quarterly inspection routine for all quick couplings in the cooling loop. During each inspection, cycle the coupling through three open-close motions to keep the poppet free and prevent sticking. Look for signs of weeping at the seal face, and check that the color-coded rings are intact. Replace any coupling that shows visible seal damage or repeated weeping. When planning maintenance, schedule coupling inspections during scheduled IT window changes, so that coupling health is verified at the same time as server swaps. Keep a maintenance log that records the date, coupling location, observed condition, and any action taken. Over time, this log reveals which couplings cycle most frequently and need proactive replacement. KITOZER also recommends training two staff members per shift on coupling operation, so that maintenance is not dependent on a single person. Proper training reduces mishandling that can cause seal damage or premature failure.
Price
From $145/pair. Contact +86 13922289957 for DN20 stainless steel coupling quote.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com
The KITOZER DN20 stainless steel quick coupling is built for primary and secondary main cooling loops where larger flow rates and maximum corrosion resistance are required. The 316L stainless steel body with FKM or EPDM seals handles deionized water, high-purity glycol solutions, and dielectric fluids with confidence. With a Cv of 14, this coupling supports rack and row-level cooling loads up to 120 kW while maintaining low pressure drop. The flat-face poppet design minimizes spillage on disconnection, making it suitable for cleanroom and sensitive electronic environments. KITOZER passes each DN20 coupling through a helium leak test option for high-purity loop applications.
Product Overview
The DN20 coupling is typically installed at the interface between the facility primary loop and the secondary CDU loop, or between a row-level manifold and the overhead piping. The flat-face design ensures that when disconnected, no fluid remains on the seal face, reducing contamination risk and eliminating the need for absorbent pads in clean environments. The 316L stainless steel construction is essential for deionized water loops where brass or aluminum would leach ions and degrade water quality. The coupling is available with panel-mount, inline, and flange terminations. The flat-face design also prevents air inclusion during connection, which is critical for closed-loop systems where dissolved air causes pump cavitation and corrosion.
Technical Specifications
Body: 316L stainless steel, electropolished interior. Seal: FKM standard, EPDM option. Working pressure: 16 bar. Burst pressure: 64 bar. Cv: 14. Temperature: minus 20 to 150 degrees Celsius. Bore: DN20. Termination: G3/4 or G1 male thread, barb for 20 mm hose. Weight: 380 grams per pair. Cycle life: 10,000 cycles. Spillage on disconnect: less than 0.1 ml. Air inclusion: negligible. Certification: CE, RoHS, NSF option. KITOZER, 5 year warranty. Passivation: ASTM A967. Helium leak test: option available.
Applications
Applications include data center primary loop isolation, CDU main inlet and outlet, row-level manifold connections, immersion cooling tank manifold connections, semiconductor fab cooling loops, pharmaceutical process cooling, and power converter cooling in renewable energy stations. It is also suitable for food and beverage process cooling where 316L cleanliness is required. Additional installations include biomedical research facility cooling, telescope and observatory instrument cooling, and superconducting magnet cooling loops. In high-performance computing HPC clusters, the coupling isolates each rack group for maintenance without draining the entire row.
Advantages and Features
The flat-face design is the standout feature: zero residual fluid on the seal face means no drip, no contamination, and faster maintenance turnaround. 316L stainless steel resists pitting and crevice corrosion even in chloride-containing environments. The high Cv means energy-efficient pump operation. FKM seals tolerate higher temperatures and chemical exposure than EPDM. The coupling is fully rebuildable in the field, extending service life beyond a decade. The electropolished interior reduces biofilm growth in potable or deionized loops. The coupling is compatible with steam-in-place cleaning for sanitary applications.
Installation and Maintenance
Use PTFE tape or a compatible anaerobic sealant on threaded connections. Align the coupling halves straight; never cross-thread or twist during engagement. After connection, gradually open the isolation valves and monitor for leaks. During disconnection, depressurize the loop and capture any small amount of residual fluid. Inspect the flat-face seals annually for scratches or flat spots. Re-lubricate with silicone grease approved for the fluid type. Keep spare seal kits on site to minimize downtime if a seal becomes damaged during maintenance. When installing in a panel, support the coupling with a backup washer to prevent stress on the poppet. Flush the loop with DI water before first fill to remove manufacturing residue. Monitor coolant resistivity quarterly if using deionized water, and replace filters as needed.
System Integration Notes
When designing a cooling system around KITOZER quick couplings, it is important to size the port for the expected flow rate and pressure drop. Undersized couplings increase pumping energy and can cause uneven cooling across the rack. Plan for access clearance around each coupling for hand operation and visual inspection. Color-code supply and return lines at every connection point to eliminate cross-connection during maintenance. For mission-critical loops, carry spare seal cartridges and at least one complete coupling pair on site. KITOZER recommends documenting each coupling location, installation date, and cycle count in the facility maintenance register. When mixing coupling brands, verify poppet profile compatibility before deployment, as not all industry profiles are fully interchangeable. Training maintenance staff on proper engagement and disconnection technique reduces cycle wear and leak incidents.
Best Practices
For best results, KITOZER recommends establishing a quarterly inspection routine for all quick couplings in the cooling loop. During each inspection, cycle the coupling through three open-close motions to keep the poppet free and prevent sticking. Look for signs of weeping at the seal face, and check that the color-coded rings are intact. Replace any coupling that shows visible seal damage or repeated weeping. When planning maintenance, schedule coupling inspections during scheduled IT window changes, so that coupling health is verified at the same time as server swaps. Keep a maintenance log that records the date, coupling location, observed condition, and any action taken. Over time, this log reveals which couplings cycle most frequently and need proactive replacement. KITOZER also recommends training two staff members per shift on coupling operation, so that maintenance is not dependent on a single person. Proper training reduces mishandling that can cause seal damage or premature failure.
Price
From $145/pair. Contact +86 13922289957 for DN20 stainless steel coupling quote.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com