The KITOZER DN25 brass quick coupling handles large-flow secondary cooling loops serving multi-rack rows and perimeter cooling manifolds. With a Cv of 22 and a working pressure of 10 bar, it supports flow rates up to 120 liters per minute in water-glycol loops. The DZR brass body and EPDM seals deliver dependable service for indoor data center and industrial process cooling. The locking sleeve and poppet shutoff design allow fast isolation of a row or zone without tools, improving maintenance response time. KITOZER sizes the DN25 for central plant secondary loops where flow balancing across rows is a primary design consideration.
Table of Contents
ToggleProduct Overview
DN25 is the typical size for row-level supply and return headers that feed multiple rack manifolds. The coupling is engineered for wall or pipe-mount installation, with wrench flats for secure mounting. The poppet valve opens fully when connected, presenting minimal flow restriction, and closes automatically when the sleeve is released. The coupling can be ordered with threaded or flanged terminations to match facility piping standards. The body is generously sized to accommodate the large poppet, which provides smooth flow transition and minimizes turbulence-induced vibration. KITOZER supplies the DN25 with mounting brackets for wall or rack installation.
Technical Specifications
Body: DZR brass, nickel-plated. Seal: EPDM. Working pressure: 10 bar. Burst pressure: 40 bar. Cv: 22. Temperature: minus 10 to 100 degrees Celsius. Bore: DN25. Termination: G1 male thread, G1-1/4 option, flange DN25 PN16. Weight: 650 grams per pair. Flow: up to 120 l/min. Cycle life: 5,000 cycles. Locking: sleeve lock. Certification: CE, RoHS. KITOZER, 3 year warranty. Mounting bracket: included. Color: blue supply, red return.
Applications
Used in row-level cooling isolation, perimeter cooling loop connections, central plant secondary loop isolation, in-row CDU supply and return, industrial chiller hookups, injection molding cooling manifolds, and large battery ESS cooling loops. Also suitable for HVAC auxiliary loops and district cooling branch connections. Additional installations include shopping mall chiller loop isolation, hospital central plant secondary loops, and university data center row isolation. In retrofit projects, the DN25 coupling allows a row to be isolated and reconnected without shutting down the entire hall.
Advantages and Features
The large bore means minimal pressure drop across the connection, reducing pump energy and allowing smaller pump selection. The robust brass body withstands repeated use in maintenance-heavy environments. Multiple termination options (thread, flange, barb) simplify integration into existing piping. Color-coded locking rings help operators distinguish supply from return at a glance. The coupling is repairable, with replacement seal cartridges and poppet assemblies available from KITOZER. The mounting bracket reduces pipe stress at the joint. The nickel-plated exterior resists corrosion in mechanical rooms.
Installation and Maintenance
Support the coupling weight with pipe hangers; do not let the coupling carry the weight of downstream hose or pipe. Use proper torque on threaded or flanged connections and apply a torque wrench to avoid over-tightening. On first fill, flush the loop before connecting to the coupling to avoid trapping welding slag or Teflon tape fragments in the poppet. Inspect poppet movement annually by cycling the coupling a few times without pressure. Replace seals every two years or 5,000 cycles. When using flange terminations, install a new gasket each time the joint is broken. Torque flange bolts in a crisscross pattern to 25 Nm. Keep a maintenance record for each row isolation point, noting the date and reason for each disconnection.
Price
From $185/pair. Contact +86 13922289957 for DN25 brass coupling pricing.