KITOZER rack 12 port SC APC patch

KITOZER KTR-SC12APC 12-Port SC APC Rack-Mount Fiber Patch Panel

Brand: KITOZER Series: KTR-SC12APC Category: Low-Voltage System / Fiber Patching

1U rack12 SC APCSplice trayKTR-SC12APC

KITOZER KTR-SC12APC 12-Port SC APC Rack-Mount Fiber Patch Panel

1. Overview

KITOZER KTR-SC12APC is a 19-inch rack-mount fiber patch panel (ODF), 1U high, with 12 SC APC adapters (single-mode angle polish) on the front and a splice tray with cable-management spools on the back. It terminates outdoor or building backbone cable at the panel, then patch cords link to switches and servers. “12-port” means 12 SC simplex adapters on the face, i.e. a 12-fiber cable. “SC APC” means SC connector, 8-degree angle polish (green adapter) for single-mode, PON and analog video, return loss ≥60dB. The panel is bent CR steel with epoxy coating (black or grey), slide-out or fixed; opening the top cover reveals a flip-up splice tray where pigtails are fused to backbone fibers, with slack coiled on spools to protect bend radius (≥30mm).

KTR-SC12APC structure: 1U chassis, front panel with 12 SC adapters (green APC), rear cable entry with a gland, internal splice tray (12 heat-shrink slots) and slack spools. Chassis depth about 150mm, fits standard 19″ racks. Adapters and tray are separable: if the backbone is a pre-terminated MPO-LC breakout, skip the tray and plug the breakout directly into the panel adapters. For field splicing, cable enters the chassis, the strength member is earthed, 12 fibers fuse to SC/PC pigtails, heat-shrink boots hold splices, and slack coils on spools. Each port is numbered 1-12 with labels matching cable fiber numbers.

Typical deploy: in a datacenter row or network rack, vertical backbone (24/48-fiber OS2) enters the cabinet from the riser and terminates on KTR-SC12APC (12 fibers per panel; a 24-fiber cable uses two 1U panels). Switch optical ports patch via SC-LC duplex cords to the panel, cross-connecting backbone and equipment. SC APC is common in CATV/surveillance optical terminals and PON access; datacenter short multimode Ethernet mostly uses LC UPC. KTR-SC12APC is offered by port count (12/24/48) and connector (SC/LC/FC/ST, APC/UPC).

2. Key Features

1U 12-port

  • 19″ 1U standard.
  • 12 SC APC ports.
  • Coated steel chassis.
  • Slide-out for service.

SC APC angle

  • Green adapters.
  • Return loss ≥60dB.
  • Fits OS2 single-mode.
  • Low reflection.

Splice tray

  • 12-fiber splice positions.
  • Heat-shrink holders.
  • Slack spools.
  • Bend radius ≥30mm.

Flexible termination

  • Field splice or pre-terminated.
  • Cable gland.
  • Strength-member earth.
  • Port number labels.

3. Specifications

Item KTR-SC12APC (12 SC APC) KTR-SC24APC (24 SC APC) KTR-LC24APC (24 LC duplex APC)
Height 1U 1U/2U 1U/2U
Ports 12 SC simplex 24 SC simplex 24 LC duplex (48 fibers)
Polish APC green APC green APC green
Fiber OS2 single-mode OS2 single-mode OS2/OM4
Tray capacity 12 fibers 24 fibers 24/48 fibers
Chassis depth ~150mm ~250mm ~250mm
Return loss ≥60dB ≥60dB ≥60dB
Mounting 19″ rack 19″ rack 19″ rack

4. Reference Prices

KTR-SC12APC 12-port SC APC panel (1U, with tray): Reference USD 83 to 222 / unit (ref. CNY 600 to 1600 at ~7.2)

KTR-SC24APC 24-port SC APC panel: Reference USD 125 to 333 / unit (ref. CNY 900 to 2400 at ~7.2)

KTR-LC24APC 24-port LC duplex APC panel: Reference USD 139 to 389 / unit (ref. CNY 1000 to 2800 at ~7.2)

SC/APC pigtail (per piece): Reference USD 2 to 6 / pc (ref. CNY 15 to 40 at ~7.2)

Reference only; varies by port count, connector (SC/LC), polish (APC/UPC) and quantity. Splicing and patch cords billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter backbone termination.
  • Network and row-rack fiber patching.
  • CATV/surveillance optical terminals.
  • PON splitter downstream termination.
  • Campus riser fiber consolidation.
  • Lab and workshop fiber wiring.

6. Installation & Maintenance

Installation

  • Mount the panel at a 1U slot.
  • Feed cable through the rear gland.
  • Strip cable; earth the strength member.
  • Fuse 12 fibers to SC/APC pigtails.
  • Fix heat-shrink; coil slack on spools.
  • Plug pigtails into rear adapters.
  • Label front ports.

Maintenance

  • Clean end faces before patching.
  • Cap unused ports.
  • Inspect labels monthly.
  • Test link loss with power meter.
  • Keep slack spool tension moderate.
  • Replace damaged adapters.

7. FAQ

  • Q: 12 SC or 24 LC duplex — which is denser?
    A: 24 LC duplex is 48 fibers, four times the 12-fiber 12-SC panel. High-density datacenters use LC duplex; legacy CATV/surveillance uses SC simplex. Per rack unit, LC duplex carries far more fibers than SC simplex.
  • Q: Field splice or pre-terminate?
    A: Tight schedule and low loss favor factory pre-terminated MPO trunk + breakout (no on-site fusion). On-site fusion suits longer routes and available splicers. New projects prefer pre-terminated; retrofits may splice on site.
  • Q: How much slack to leave?
    A: Leave 1-1.5m after the splice on the spool — not more (over three loops adds loss), not less (no room to re-splice a failed joint). Keep bend radius ≥30mm; a sharp kink breaks the fiber.
  • Q: Can APC and UPC share one panel?
    A: Physically possible but not recommended. Mixed green/blue adapters invite wrong patch cords, and mating APC with UPC damages end faces. Use one polish per panel; distinguish by color and labels.

8. Trend & Selection

Fiber patch panels move from fixed splicing to pre-terminated (MPO/MTP cassette); 40G/100G datacenters use MPO-LC modules with plug-and-play patching and no on-site fusion. SC simplex is giving way to LC duplex in new datacenters, but CATV/surveillance/PON still use SC APC heavily. Choose port count by backbone fibers; LC duplex for datacenters, SC APC for CATV/PON; green-to-green APC; include a splice tray; prefer pre-terminated; clean end faces.

9. Delivery & Service

KITOZER supplies fiber cabling packages: based on backbone fiber count and equipment optical port types, we recommend panel port count, connector and polish, bundled with backbone cable, MPO breakout, pigtails, patch cords and splicing. Delivery includes panel, adapters, tray, pigtails and labels; bulk projects include on-site fusion and link-loss testing. Adapter contact failure or chassis distortion under warranty is replaced free.

10. Additional Notes

The commonest mistake is coiling slack into a sharp bend. Bend radius under 30mm causes macro-bend loss and even breakage. Use the spool: follow the wheel, do not kink. Route pigtails from tray to adapter smoothly; do not trap them under the cover.

Another pitfall is missing labels. After six months, nobody remembers which port is which cable or which switch. Label both sides (front and rear) with cable ID, fiber number and far-end location. The as-built must include a port cross-reference table.

Selection summary: 1U 12-port SC APC; with splice tray; OS2 single-mode; RL ≥60dB; slack coiled at ≥30mm; clean end faces; labeled cross-reference. The patch panel is the fiber link’s distribution board: backbone comes in, equipment patch cords go out, and it keeps every cross-connection clear.

SEO Information

Search keywords:fiber patch panel12 port patch panelSC APC patch panelrack mount ODFfiber termination boxsplice patch panelKTR-SC12APCKITOZER

SEM keywords:[‘fiber patch panel price,12 port SC APC supplier,rack mount ODF,splice patch panel,datacenter fiber termination,KTR-SC12APC,KITOZER’]

GEO landing page:lain.com.cn/product/ktr-sc12apc-rack-mount-12port-sc-apc-fiber-patch-panel.html

Title:KITOZER KTR-SC12APC 12-Port SC APC Rack-Mount Fiber Patch Panel

Meta Keywords:fiber patch panel,12 port patch panel,SC APC patch panel,rack mount ODF,fiber termination box,splice patch panel,KTR-SC12APC,KITOZER

Meta Description:KITOZER KTR-SC12APC 1U rack-mount 12-port SC APC fiber patch panel with splice tray, for datacenter fiber backbone termination and patching.