KITOZER
KITOZER

KITOZER rack 12 port SC loaded box

KITOZER KTR-FB12S2 Rack 12-port SC Loaded Fiber Box

Brand: KITOZER Series: KTR-FB12S2 Category: Data Center Engineering / Fiber distribution

19-inch rack12-port SC loadedSplice traySC/PC pigtailSliding drawer

[Product image: ktr-fb12s2-rack-12port-sc-loaded-fiber-box.jpg]

1. Overview

The fiber distribution box (ODF unit, fiber patch panel, fiber termination box) is the first termination point where backbone cables enter a rack. Inside, the cable is anchored, stripped, spliced and coiled, then patched through adapters to switch optics. A well-designed box lets technicians patch and test any one fiber without disturbing the others.

The KITOZER KTR-FB12S2 is a rack 12-port SC fully loaded fiber box. The chassis is 1.2 mm cold-rolled steel powder-coated RAL9005, 1U high, fitting a 19-inch rack. The front panel carries 12 SC duplex adapters (24 fibers), pre-installed and fixed. Inside are two splice trays holding 12 splices; pigtails are coiled on storage rings with a bend radius >=30 mm. Top and bottom cable entries have rubber grommets to protect the jacket. The drawer slides forward with a stop so it cannot fall out. Twelve SC/PC single-mode pigtails and 12 SC adapters are included, so the customer only needs to splice the incoming cable; this is the loaded configuration.

Selection confirms fiber count (12/24/48 ports), connector type (SC/LC), mode (single-mode/multimode), and whether loaded pigtails are required. KTR-FB12S2 is 12-port SC single-mode loaded, ideal for a 12-fiber backbone. For 24-fiber cables, choose the 24-port version; if the switch side uses LC optics, choose LC adapters or add SC-LC patch cords. Depth suits a standard 900 mm rack and does not interfere with adjacent units when the drawer is pulled.

2. Key Features

19-inch chassis

  • 1U, 19-inch standard.
  • 1.2 mm cold-rolled steel, RAL9005.
  • Front-sliding drawer with stop.
  • M6 rack bolts included.

12-port SC loaded

  • 12 SC duplex adapters on panel (24 fibers).
  • 12 SC/PC single-mode pigtails preinstalled.
  • Ceramic-sleeve adapters, IL <=0.2 dB.
  • Dust caps on every port.

Splice and coil

  • Dual splice tray holds 12 splices.
  • Bend radius >=30 mm on storage rings.
  • Cable entry with rubber grommet.
  • Splice-sleeve holders.

3. Specifications

Item Specification
Rack size 19-inch, 1U
Ports 12 SC duplex (24 fibers)
Mode OS2 single-mode 9/125 um
Adapter polish SC/PC blue
Pigtails SC/UPC single-mode, 12 pcs
Splice capacity 12 fibers (dual tray)
Steel gauge 1.2 mm cold-rolled
Finish Powder coat RAL9005
Cable entry Top and bottom, rubber grommet
Mounting 19-inch rack, M6 bolts

4. Reference Prices

KTR-FB12S2 12-port SC single-mode loaded box: USD 53~78 (ref. CNY 380~560 at ~7.2)

Spare SC/PC single-mode pigtail (1.5 m): USD 1.7~2.8 (ref. CNY 12~20 at ~7.2)

Spare SC duplex SM adapter: USD 0.85~1.4 (ref. CNY 6~10 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Backbone cable termination in racks.
  • Core switch optic patching.
  • ODF expansion units.
  • Telecom room fiber cross-connect.
  • FTTH fiber-to-the-desk termination.

6. Installation & Maintenance

Installation

  • Bolt the box to a 1U rack position.
  • Feed backbone cable through the top entry.
  • Strip 2 m of jacket and anchor the strength member.
  • Splice each fiber to an SC pigtail and heat the sleeve.
  • Coil pigtails neatly on the tray.
  • Insert SC heads into panel adapters.
  • Test every fiber with OTDR or power meter.

Maintenance

  • Check dust caps monthly.
  • Clean adapter sleeves quarterly.
  • Pull the drawer gently.
  • Trace labels when adding links.
  • Do not overfill the splice tray.

7. FAQ

  • Q: Loaded vs unloaded?
    A: Loaded ships with adapters and pigtails pre-installed, so on-site work is just splicing. Unloaded is an empty chassis requiring you to source pigtails and adapters. KTR-FB12S2 is loaded for fast project delivery.
  • Q: How many fibers do 12 ports carry?
    A: SC duplex is 2 fibers per port (TX/RX), so 12 ports = 24 fibers; the splice tray holds 12. For a 24-fiber cable, choose the 24-port version.
  • Q: How to connect to LC optics?
    A: Either switch to LC adapters, or use an SC-LC patch cord; the latter is cheaper but adds one more connector pair.
  • Q: Can the drawer come all the way out?
    A: It slides to a stop with enough room for splicing; fully removing requires loosening the rail screws on both sides.

8. Trend & Selection

Backbones have moved from 1G to 10/40/100G, and patch boxes are evolving from empty chassis to pre-loaded units that cut on-site splicing. Pre-terminated MPO/MTP is taking over high-density rooms, but SC remains mainstream in small and mid-size sites. Match port count to fiber count; choose loaded for fast delivery; blue UPC for OS2; reserve 20% spare ports; label both ends consistently.

9. Delivery & Service

KITOZER ships KTR-FB12S2 with chassis, 12 SC duplex adapters, 12 SC SM pigtails, M6 bolts, certificate and manual, plus splicing and coiling guidance.

10. Notes

A common mistake is not leaving pigtail slack. Leave 20 to 30 cm of coiled slack on the tray so that future re-splicing or module swaps are possible without starting over.

Another pitfall is missing dust caps. Dust inside adapters scratches ferrule end faces and raises link loss; cleaning later means pulling the drawer, which costs more than a cap.

Selection summary: 1U rack; 12 SC duplex loaded; OS2 single-mode; dual splice tray; sliding drawer; black powder coat. It is the basic termination unit for in-rack backbone fibers.

Systemically, the patch box is the most-handled node of the fiber plant; poor labeling and over-tight coiling can take down production links during a single patch, costing more in downtime than the box itself.

Cost-wise, a loaded box around 500 CNY saves about 2 hours of on-site assembly, paying back versus 300 CNY/hour field labor.

SEO Information

Search keywords: KITOZER

SEM keywords: fiber distribution box, rack 12-port, SC loaded, ODF unit, fiber patch, KTR-FB12S2, KITOZER

GEO landing page: lain.com.cn/product/454_fiber_box_12s2.html

Title: KITOZER KTR-FB12S2 Rack 12-port SC Loaded Fiber Box

Meta Keywords: fiber distribution box, rack 12-port, SC loaded, ODF unit, fiber patch, KTR-FB12S2, KITOZER

Meta Description: KITOZER KTR-FB12S2 rack 12-port SC loaded fiber box with splice tray and pigtails, for data center fiber termination.

Anchor: KITOZER · KITOZER Products