KITOZER
KITOZER

KITOZER rack 24 LC APC OM3

KITOZER KTR-LC24APC3 24-Port LC APC OM3 Rack Fiber Patch Panel / High-Density Termination

Brand: KITOZER Series: KTR-LC24APC3 Category: Data Center Engineering / Fiber Patch Panel

24-port LCAPCOM3 MMF1U rackKTR-LC24APC3

KITOZER KTR-LC24APC3 rack-mount 24-port LC APC OM3 fiber patch panel

1. Overview

KITOZER KTR-LC24APC3 is a rack-mount 24-port LC APC OM3 fiber patch panel, the core termination and patching device in data center weak-current systems. Trunk cables enter the room and are terminated on the panel, converting every fiber to a standard LC interface, then LC-LC jumpers run to switch SFP ports or server NICs. A 24-port panel occupies 1U, with 24 LC adapters (12 duplex LC ports) on the front and a splice tray on the back that holds the trunk cable and pigtails—the bridge between trunk cable and equipment jumpers.

LC APC means: LC is the small duplex connector; APC is the 8° angle polish with high return loss (≥60dB), suited to single-mode long-haul and WDM links. OM3 is the multimode spec (aqua jacket) for 10G/40G/100G parallel multimode. This panel packs 24 LC APC adapters into 1U, with a rear splice tray and cable anchor; trunk cable is fused to LC pigtails, splices held in the tray, and the front adapters serve as the coupling window. It pairs with MPO trunk panels in a two-tier architecture: trunk termination plus breakout patching.

The panel is cold-rolled steel with a powder coat and a removable splice tray. Adapter color matches fiber type: aqua for OM3 multimode, green for APC. The rear cable is tied down and the strength member grounded. Port numbers on a label strip aid maintenance. It mounts on 19-inch rails with square-hole screws. 1U/24-port balances density and serviceability: too few ports wastes space, too many crowds jumpers and bends radius.

2. Key Features

24-port high density

  • 24 LC ports (12 duplex) in 1U.
  • OM3 multimode for 10G/40G parallel links.
  • APC polish for high return loss.

Rear splice storage

  • Removable tray holds pigtails and splices.
  • Cable anchor and strength-member ground.
  • Bend radius kept low for macro-bend loss.

Structure & install

  • Steel powder coat, 19-inch rack.
  • Adapter color by spec.
  • Numbered label strip for clarity.

Link compatibility

  • LC-LC duplex jumpers.
  • Pairs with MPO trunk panels.
  • Supports OM3 loss budget.

3. Specifications

Item KTR-LC24APC3 KTR-LC24UPC3 KTR-LC48APC3
Ports 24 (12 duplex LC) 24 (12 duplex LC) 48 (24 duplex LC)
Connector LC APC green LC UPC blue LC APC green
Fiber type OM3 MMF OM3 MMF OM3 MMF
Height 1U 1U 2U
Insertion loss (dB) ≤0.3 ≤0.3 ≤0.3
Return loss (dB) ≥60 (APC) ≥30 (UPC) ≥60 (APC)
Splice tray removable removable removable
Mounting 19-inch rack 19-inch rack 19-inch rack

4. Reference Prices

KTR-LC24APC3 24-port LC APC OM3 panel (1U, splice tray, green adapters): Reference USD 39~72 / piece (ref. CNY 280~520 at ~7.2)

KTR-LC24UPC3 24-port LC UPC OM3 panel (1U, blue adapters, PC): Reference USD 33~64 / piece (ref. CNY 240~460 at ~7.2)

KTR-LC48APC3 48-port LC APC OM3 panel (2U, high density, dual tray): Reference USD 67~122 / piece (ref. CNY 480~880 at ~7.2)

Reference only; by port count, polish and fiber type. Pigtails, splicing and jumpers excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Trunk cable termination in data halls.
  • Patching switch SFP ports to server NICs.
  • ODF deployment in IDF/MDF rooms.
  • Second-tier termination from MPO trunks to LC.
  • High-density 10G/40G multimode cabling.

6. Installation & Maintenance

Installation

  • Mount the panel in 1U of rack space.
  • Bring trunk cable in the rear and anchor it.
  • Strip jacket; fuse each fiber to a pigtail.
  • Hold splices in the tray with bend radius.
  • Ground the strength member.
  • Insert front LC adapters and label ports.
  • Spot-check insertion loss with source/power meter.

Maintenance

  • Keep dust caps on unmated ports.
  • Clean adapter end faces periodically.
  • Let jumpers drop through brush/manager.
  • Keep the tray closed to keep dust out.
  • Keep labels matching the link diagram.

7. FAQ

  • Q: Can APC and UPC mate?
    A: Physically LC APC (green) and LC UPC (blue) fit, but mating an angle to a plane wears the APC end face and ruins return loss. Always APC-to-APC and UPC-to-UPC; tell them by color.
  • Q: Are OM3 and OM4 panels interchangeable?
    A: Adapters are common, but budget link length per OM3 (100m at 40G) or OM4 (150m); keep panel color consistent with jumpers.
  • Q: 24 or 48 ports?
    A: Choose 1U/24 for fewer ports with room to grow; choose 2U/48 for dense racks. Watch jumper crowding at 48 ports.
  • Q: Field splice or pre-terminated?
    A: Field splicing suits uncertain cable lengths and cost sensitivity; pre-terminated panels come with factory-fused pigtails for fast MPO trunk deployment at higher cost.

8. Trend & Selection

Data center fiber moves toward high-density pre-termination, evolving from 1U/24 to 2U/48 and modular MPO panels. Choose 24/48 by port need; APC for single-mode long-haul, UPC for multimode; aqua OM3 adapters; keep bend radius in the tray; pair with MPO trunk panels; label clearly.

9. Delivery & Service

KITOZER selects panels by trunk fiber count, equipment port count, link distance and fiber type, configuring 24/48, APC/UPC and OM3. We provide a port map and link loss budget. Delivery includes panel body, adapters, splice tray, anchor and label strip. Warranty covers splicing guidance and loss re-test.

10. Additional Notes

The common pitfall is mixing APC and UPC: single-mode long-haul uses green APC adapters but jumpers are blue UPC; an angle-to-plane mate wears the APC bevel after a few insertions and return loss collapses. Enforce color discipline: green APC only with green APC jumpers, blue UPC only with blue UPC jumpers.

Another pitfall is over-tight pigtail routing in the tray: a sharp kink raises macro-bend loss, so the link tests through but fails loss budget. Coil pigtails loosely with bend radius ≥30mm, not over the splice protector.

Selection summary: 24/48 by port need; APC-to-APC and UPC-to-UPC; aqua OM3; keep bend radius in the tray; pair with MPO trunks; labels match the diagram. The panel is the fiber termination point—pick the right polish and density and high-speed links stay stable.

SEO Information

Search keywords:24-port panelLC APCOM3rack ODFhigh densityKTR-LC24APC3KITOZER

SEM keywords:24 port LC patch panel price,OM3 fiber patch panel supplier,rack ODF,KTR-LC24APC3

GEO landing page:lain.com.cn/product/ktr-lc24apc3-24-port-lc-apc-om3-rack-patch-panel.html

Title:KITOZER KTR-LC24APC3 24-Port LC APC OM3 Rack Fiber Patch Panel / High-Density Termination

Meta Keywords:24 port fiber patch panel,LC APC patch panel,OM3 patch panel,rack mount ODF,24 port LC fiber box,high density panel,KTR-LC24APC3,KITOZER

Meta Description:KITOZER KTR-LC24APC3 rack-mount 24-port LC APC OM3 fiber patch panel for data center termination and high-density patching over OM3 multimode links.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart