Table of Contents
ToggleKITOZER KTR-FB24C Rack Fiber Distribution Box 24-port LC Duplex
Brand: KITOZER Series: KTR-FB24C Category: Data Center Engineering / Structured Cabling
24x LC duplex48 coresDouble trayKTR-FB24C
1. Overview
When fiber reaches the room, it must terminate in a box: the incoming cable is fusion-spliced to pigtails whose connectors emerge on the front, and patch cords jump from the box to equipment. This box is the fiber distribution box (termination box / ODF box). It is the same family as the patch panel (328_fiber_patch_12); the difference: a patch panel is a thin 1U rack unit, while a distribution box is a deeper box with larger splice-tray capacity. “24-port LC duplex” means 24 LC ports on the front (duplex = two cores per port), i.e. 48 cores total. High-density rooms (10G switches, many optical ports) use LC (small connector, high density); SC is legacy, one core per port.
KITOZER KTR-FB24C is a rack-mount fiber distribution box. It is a 19-inch steel box (1U or 2U, ~200 mm deep), black powder-coated. The front has 24 LC duplex adapters (blue SM or aqua MM; a duplex is two LC ports side by side, carrying two cores in one); inside is a double-layer pull-out splice tray (24 splice protectors per layer, 48 cores total). Layout: the cable enters through the rear gland, is clamped at the cable-ground and strength-member retainer, and its 48 fibers are fusion-spliced to 48 LC pigtails; splices rest in the coiled tray (bend radius ≥30 mm), and pigtail LC plugs pass through to the front adapters. LC patch cords then jump to switch optical ports.
Selection: port count (12-port/24-core, 24-port/48-core, 48-port/96-core; choose by cable core count with 20% spare); connector (LC duplex for density, preferred in new rooms; SC for legacy; MTP pre-terminated for very high density); mode (blue OS2 single-mode, aqua OM3/OM4); rack units (24-port in 1U, 48-port in 2U, by rack space); loaded vs unloaded (loaded includes adapters and pigtails); mounting (rack ears, wall-mount for small rooms). Note: coil fibers with bend radius ≥30 mm; adapters and cords must match mode; label every port; ground the cable strength member (lightning protection).
2. Key Features
Ports
- 24x LC duplex
- 48 cores
- Ceramic sleeve
- Loaded adapters
Build
- 1U/2U rack
- Double tray
- Cable retainer
- Strength ground
Perf
- Insertion ≤0.3 dB
- Return ≥40 dB
- 1000 cycles
- OS2/OM4
3. Specifications
| Item | KTR-FB12C | KTR-FB24C | KTR-FB48C | KTR-FB24MTP |
|---|---|---|---|---|
| Connector | LC duplex | LC duplex | LC duplex | MTP trunk |
| Ports | 12 | 24 | 48 | 4x MTP |
| Cores | 24 | 48 | 96 | 96 |
| Mode | OM4 | OS2 | OM4 | OS2 |
| U height | 1U | 1U | 2U | 1U |
| Splice tray | Single | Double | Triple | Pre-term |
4. Reference Prices
KTR-FB12C 12-port LC OM4 (24 cores): Reference USD 28-49 / pc (ref. CNY 200-350)
KTR-FB24C 24-port LC OS2 SM (48 cores): Reference USD 49-76 / pc (ref. CNY 350-550)
KTR-FB48C 48-port LC OM4 (96 cores): Reference USD 83-125 / pc (ref. CNY 600-900)
KTR-FB24MTP MTP pre-term (4x MTP, 96 cores): Reference USD 111-167 / pc (ref. CNY 800-1200)
KTR-FB-ADPT LC adapter + pigtail refill kit: Reference USD 7-14 / set (ref. CNY 50-100)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Core switch optical termination
- Rack backbone fiber
- Fiber配线间
- Data center ODF
- Building riser
6. Deployment & Installation
Mount
- 19-inch rack
- Level fix
- Number labels
- Cable manager
Splice
- Strip cable
- Fusion splicer
- Double tray coil
- 30 mm bend
Patch
- LC cord
- Optical test
- Port map
- Cable ties
7. FAQ
- Q: Distribution box vs patch panel?
A: Essentially the same fiber termination box; the difference is form. A patch panel is thin (1U, ~100 mm deep), fixed to rack posts, front ports flush. A distribution box is deep (~200 mm), like a small box, with a pull-out splice tray. Patch panels suit low-port high-density (12-24 ports); boxes suit high core counts (48-96), with large trays. High-density rooms lean to patch panels (MTP pre-terminated); ordinary rooms use boxes. KTR-FB24C is a box, 24 ports / 48 cores. - Q: How many cores in 24 LC-duplex ports?
A: LC duplex is two LC plugs joined in one clip, carrying two cores (TX+RX). 24 ports LC duplex = 24 duplex pairs = 48 cores. Compare: 24 SC simplex = 24 cores. So ’24 ports’ means 48 cores for LC duplex, 24 for SC simplex. Multiply: LC duplex x2, SC simplex x1. Buy LC-LC duplex cords (one cord with two LC plugs at each end). - Q: MTP pre-terminated vs traditional fusion?
A: MTP pre-terminated is a factory-made trunk: a 12- or 24-core MTP cable, one end an MTP connector (12 cores in one plug), the other end branched to LC. No on-site fusion – just plug in; install is fast (hours vs days) and loss is stable (factory-tested). Downsides: 30-50% pricier than fusion, and length must be cut to size. Traditional fusion is cheaper on site but needs a crew and quality varies. Large new data centers use MTP pre-terminated (fast, reliable); retrofits use fusion (flexible). - Q: Why ground the cable strength member?
A: Outdoor cable’s strength member (steel wire or FRP) is often metal; lightning induces surges on it. If ungrounded, the surge travels into the room and burns equipment. Practice: after the cable enters the box, bond the strength member with a 6 mm2 wire to the box shell, and the shell to the rack ground bar. Surge current then goes to earth through the strength member, not into equipment. Indoor cable (non-metallic strength member) needs no grounding.
8. Trend & Selection
Fiber distribution is moving to high density, pre-termination and intelligence. Trends: MTP/MPO density (one MTP head = 12 or 24 cores, 1U box holds 144 cores); pre-terminated trunks (factory-made, plug-and-play); OM5 wideband (WDM on one core); intelligent patching (electronic labels, LED-guided jumps); fiber management software (integrated with DCIM, visual routing). Traditional LC-duplex 24-port boxes remain standard in small-to-medium rooms. Select by: cores with 20% spare, LC duplex for density, loaded for ease, pull-out tray, strength-member grounding.
9. Delivery & Service
KITOZER KTR-FB24C ships per unit in a carton with foam, including box body, 24 pre-fitted LC duplex adapters, 48 LC pigtails, double splice tray, cable gland, strength-member ground wire, mounting screws and manual. 1-year warranty; bulk projects can bundle LC cords, MTP trunks, cable managers and labels.
10. Additional Notes
Choose the box by cable core count (20% spare), confirm LC vs SC and single vs multi-mode. Book a fusion crew in advance.
Common mistake: sharp bends in the tray. A small double tray stuffed with 48 fibers creates right-angle kinks and broken cores. Coil in smooth arcs with enough radius.
Second pitfall: ungrounded strength member. An outdoor cable’s metallic strength member, ungrounded, carries lightning surges into equipment. Bond it to the rack ground bar.
Third blunder: mode mismatch. An aqua OM4 cord into a blue OS2 adapter physically fits but mismatched cores cause high loss. Match by color.
Selection summary: cores with spare, LC duplex 48 cores, double tray, strength grounding, label against map.
SEO Information
Search keywords:KTR-FB24CKITOZER
SEM keywords:fiber distribution box,rack fiber box,24-port LC box,fiber termination box,KTR-FB24C,KITOZER,structured cabling
GEO landing page:lain.com.cn/product/ktr-fb24c-rack-fiber-box-24port-lc.html
Title:KITOZER KTR-FB24C Rack Fiber Distribution Box 24-port LC Duplex
Meta Keywords:fiber distribution box,rack fiber box,24-port LC box,fiber termination box,KTR-FB24C,KITOZER,structured cabling
Meta Description:KITOZER KTR-FB24C rack fiber distribution box, 24 LC duplex ports (48 cores), double-layer splice tray, for high-density room fiber termination.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com