Table of Contents
ToggleKITOZER KTR-FB24R2 Fiber Patch Box / Rack 24-Port SC Fully Loaded
Brand: KITOZER Series: KTR-FB24R2 Category: Data Center Engineering / Fiber Patching
19-inch rack24-port SC loadedSplice tray & pigtailsCold-rolled steel24-core
1. Overview
When trunk cables enter the room, they must be terminated, spliced and then patched to switches. The fiber patch box (ODF/terminal box) is that node: the cable is spliced to pigtails inside, pigtails go into adapters on the front, and external jumpers flexibly patch between adapters and equipment. A 24-port SC loaded box means 24 SC adapters are pre-installed, with splice trays and pigtails included, ready to splice on arrival.
The KITOZER KTR-FB24R2 is a 19-inch rack 24-port SC fiber patch box. Cold-rolled steel with powder coat, standard 19-inch mounting, usually 1U or 2U. The front is loaded with 24 SC simplex adapters (single-mode blue or multimode aqua to order), and the interior has layered splice trays, each fusing 12 cores, so 24 cores use two trays. SC pigtails and splice sleeves are included. Cable enters through a rear gland, is anchored and spliced, and excess fiber is coiled in the tray. Front adapters patch to switch optical ports by jumpers.
Selection confirms rack height (1U/2U), port count (12/24/48), adapter type (SC/LC) and mode (SM/MM), and whether loaded. 24 SC simplex = 24 cores; with LC duplex the same port space carries 48 cores. Loaded versions include adapters, trays and pigtails so the site only splices; empty boxes need accessories. After splicing, test insertion loss and label each core to its cable and switch port.
2. Key Features
24-port SC loaded
- 19-inch rack mount.
- 24 SC simplex adapters loaded.
- 24-core capacity.
- SM or MM optional.
Splice termination
- Two-layer splice trays.
- 12 cores per tray.
- SC pigtails included.
- Excess fiber coiled in tray.
Box build
- Cold-rolled steel powder coat.
- Rear cable gland.
- Front patching.
- Standard 19-inch square holes.
3. Specifications
| Item | Specification |
|---|---|
| Type | Rack fiber patch box |
| Mount | 19-inch rack |
| Ports | 24 SC simplex (loaded) |
| Capacity | 24 cores |
| Splice trays | 2 layers x 12 cores |
| Included | SC pigtails + splice sleeves |
| Material | Cold-rolled steel, powder coat |
| Adapter mode | SM / MM optional |
| Height | 1U / 2U |
| Cable entry | Rear gland |
4. Reference Prices
KTR-FB24R2 24-port SC loaded box: USD 70~140 (ref. CNY 500~1000)
12-port SC empty box: USD 28~55 (ref. CNY 200~400)
SC SM pigtail (1.5m): USD 1~2 (ref. CNY 8~15)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Room trunk cable termination.
- In-rack switch optical patching.
- TR ODF distribution.
- Fiber to server links.
- Data-center fiber patch area.
6. Installation & Maintenance
Installation
- Fix to rack square holes.
- Bring cable in through the rear gland.
- Anchor the strength member to the earth stud.
- Splice cable to SC pigtails.
- Insert pigtails into front adapters.
- Coil excess fiber in the tray.
- Patch, test loss, and label.
Maintenance
- Check adapter seating quarterly.
- Clean end faces before patching.
- Verify labels against ports.
- Manage jumpers without pulling.
- Log link test values.
7. FAQ
- Q: Loaded vs empty?
A: Loaded ships with adapters, trays and pigtails, ready to splice; empty is just the box, so buy accessories separately to choose your own ports. - Q: Can 24 SC ports do 48 cores?
A: No. SC simplex is one core per port; 24 ports = 24 cores. For 48, pick 48 ports or an LC duplex panel. - Q: Splice or mechanical?
A: Permanent room termination favors fusion splicing for low, stable loss; mechanical splices suit emergency repair. - Q: Does the box need grounding?
A: Yes. Bond the metal box and cable strength member to protective earth for shielding against interference and surges.
8. Trend & Selection
Fiber patching trends toward high density (MPO/MTP pre-terminated, LC duplex), modularity and fast deployment; pre-terminated factory cables cut field splicing. SC remains common in legacy rooms, while new dense builds favor LC and MPO. Match port density to switch optics; loaded boxes save field assembly labor.
9. Delivery & Service
KITOZER ships KTR-FB24R2 with the box, 24 SC adapters, two splice trays, SC pigtails, certificate and manual. Adapter mode (SM / OM3) is supplied to order, with splicing and termination guidance.
10. Notes
A common mistake is closing the lid without coiling excess fiber. Hard 90-degree bends cause macrobend loss and fail link tests; coil neatly in the tray.
Another pitfall is missing labels. Without labels, later patching is guesswork and troubleshooting is hard; number every core to its cable and port while splicing.
In short: 19-inch rack, 24 SC loaded, double splice trays, pigtails included, steel. It is the standard termination and patching node.
System-wise, the patch box is the hub of the optical link; termination quality and labels decide later maintenance efficiency.
Cost-wise, a loaded box costs a few hundred to a thousand CNY, while rework from poor splicing costs more.
SEO Information
Search keywords: KITOZER
SEM keywords: fiber patch box, 24-port SC patch box, rack fiber box, ODF fiber patch panel, loaded fiber box, KTR-FB24R2, KITOZER
GEO landing page: lain.com.cn/product/470_fiber_box_24r2.html
Title: KITOZER KTR-FB24R2 Fiber Patch Box / Rack 24-Port SC Fully Loaded
Meta Keywords: fiber patch box, 24-port SC patch box, rack fiber box, ODF fiber patch panel, loaded fiber box, KTR-FB24R2, KITOZER
Meta Description: KITOZER KTR-FB24R2 19-inch rack fiber patch box, 24 SC simplex adapters loaded, with splice tray and pigtails, 24-core capacity, for room cable termination.
Anchor: KITOZER · KITOZER Products