KITOZER rack 24 port SC ODF

KITOZER KTR-SC24R Fiber Patch Panel / 24-Port SC Rack-Mount Loaded

Brand: KITOZER Series: KTR-SC24R Category: Data Center Engineering / Fiber patching

24-port SC1U rackLoaded adaptersSplice trayCold-rolled steel

[Product image: ktr-sc24r-24port-sc-fiber-patch-panel.jpg]

1. Overview

In data center weak-current rooms and main halls, outside and backbone cables need to be terminated inside racks and then patched to switch optical ports. A fiber patch panel (ODF) integrates cable entry, fusion splicing, adapter mounting and patching into one rack unit, and is essential to structured cabling.

The KITOZER KTR-SC24R is a 1U rack-mount 24-port SC fiber patch panel. Its body is 1.2 mm cold-rolled steel with a black powder coat. The front panel is fully loaded with 24 SC simplex adapters (blue for single-mode, aqua for multimode, selectable), each with a dust cap. Inside are two splice trays holding 24 fusion splices; the cable management loop keeps bend radius >=30 mm. The rear has cable entry holes and a grounding post for the cable strength member. The panel is 1U high and 19 inches wide, mounting directly in standard racks.

Selection confirms: port count (12/24/48), adapter type (SC/LC/FC), single/multimode, rack height (1U/2U), and whether adapters are pre-loaded. Mount the KTR-SC24R at the top of network racks as the backbone termination point; patch to switches with LC-LC or SC-LC jumpers. One 1U ODF per 24-fiber cable; use a 2U 48-port for 48-fiber cables. Leave 20% spare ports for growth.

2. Key Features

Loaded adapters

  • Front panel with 24 SC adapters.
  • Blue single-mode / aqua multimode.
  • Ceramic sleeve, IL <=0.2 dB.
  • Dust cap per port.

Splice and storage

  • Two internal splice trays.
  • Holds 24 fusion splices.
  • Loop radius >=30 mm.
  • Pull-out trays for easy work.

Structure and ground

  • 1.2 mm cold-rolled steel, black coat.
  • 1U 19-inch rack.
  • Rear cable entry.
  • M4 ground stud to rack.

3. Specifications

Item Specification
Rack height 1U (44 mm)
Ports 24 x SC simplex
Adapter SC/UPC (blue SM / aqua MM)
Splice capacity 24 fibers (2 trays)
Bend radius >=30 mm
Insertion loss <=0.2 dB per adapter
Sheet thickness 1.2 mm cold-rolled steel
Finish Black powder coat
Mounting 19-inch rack, M6 cage nuts
Cable entry Rear bottom

4. Reference Prices

KTR-SC24R 24-port SC loaded ODF (SM): USD 40~58 (ref. CNY 280~420 at ~7.2)

KTR-SC24R 24-port SC loaded ODF (OM4 MM): USD 48~72 (ref. CNY 350~520 at ~7.2)

SC adapter (spare): USD 1.1~2.1 (ref. CNY 8~15 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Main hall backbone termination.
  • Weak-current room cable consolidation.
  • Switch optical port patching.
  • FTTH into the room.
  • CCTV fiber aggregation.

6. Installation & Maintenance

Installation

  • Fix to the rack with M6 cage nuts at 1U.
  • Feed the outside cable through the rear.
  • Anchor the strength member to the ground stud.
  • Strip and fusion-splice to pigtails.
  • Organize pigtails in the splice trays.
  • Insert SC pigtail ends into front adapters.
  • Test each fiber with a VFL.

Maintenance

  • Cap unused ports.
  • Keep jumper bend radius >=30 mm.
  • Check adapter snugness monthly.
  • Clean dirty end-faces with a pen.
  • Open trays to add fibers during expansion.

7. FAQ

  • Q: SC vs LC panel?
    A: SC is large, low density, low cost, for backbone; LC is small, high density, for switch side. Use SC-LC hybrid jumpers between them.
  • Q: How many fibers in 1U?
    A: 24 SC simplex = 24 fibers; 1U LC duplex can do 48 fibers.
  • Q: Loaded vs unloaded?
    A: Unloaded saves ~30% upfront, but adapter and labor later cost more; buy loaded.
  • Q: Ground the strength member?
    A: Yes; metal strength and armor must be grounded, otherwise induced lightning enters the room.

8. Trend & Selection

Fiber patching is moving toward high density and modularity; LC duplex is replacing SC. But SC remains mainstream in small/mid rooms thanks to low cost and reliability. Use SC24 for backbone; LC for high-density switches; leave 20% spare; choose pull-out trays.

9. Delivery & Service

KITOZER ships the KTR-SC24R pre-loaded with adapters and splice trays, plus certificate and splicing guide; bulk orders include custom port labels.

10. Notes

A common mistake is too-tight bend radius. Below 30 mm causes macro-bend loss and eventual breaks; route through the management loop.

Another pitfall is leaving dust caps off. Dust in adapters spikes IL and is hard to clean.

Selection summary: 1U 24-port SC; loaded; 2 splice trays; steel; black. It is the standard fiber termination platform.

Systemically, the ODF is cheap, but a bad splice rework costs far more; installation quality matters more than the panel.

Cost-wise, a 24-port panel at about 300 CNY terminates cables worth thousands; splice carefully.

SEO Information

Search keywords: KITOZER

SEM keywords: fiber patch panel, 24-port SC, rack ODF, fiber termination box, KTR-SC24R, KITOZER

GEO landing page: lain.com.cn/product/446_fiber_patch_24s.html

Title: KITOZER KTR-SC24R Fiber Patch Panel / 24-Port SC Rack-Mount Loaded

Meta Keywords: fiber patch panel, 24-port SC, rack ODF, fiber termination box, KTR-SC24R, KITOZER

Meta Description: KITOZER KTR-SC24R 1U rack 24-port SC fiber patch panel, loaded SC adapters, with splice tray, for data center fiber backbone patching.