ToggleKITOZER KTR-SC24APC 24-port SC APC OM3 Rack Fiber Patch Panel
Brand: KITOZER Series: KTR-SC24APC Category: Data Center Engineering / Fiber Patch Panel
24-port SCAPC greenOM3 multimode1U rack
1. Overview
[‘The KITOZER KTR-SC24APC is a 1U rack fiber patch panel (ODF / enclosure) with 24 SC duplex APC adapters for OM3 multimode, used to terminate and patch backbone fiber in telecom rooms or rack cabinets. The 19-inch 1U unit contains a splice tray, fiber guides and an adapter panel. Cable enters from the rear; fibers are fusion-spliced to pigtails, coiled in the splice tray, with adapters fixed on the front panel. Equipment patches in via SC-LC or SC-SC jumpers, routing backbone to switch ports. 24 duplex = 48 fibers OM3, a common size for mid-size room backbone termination.’, ‘The KTR-SC24APC is 1.2 mm cold-rolled steel with black powder coat. The front panel holds 24 SC duplex APC adapters (48 fibers OM3), green APC polish. The internal splice tray holds 48 fibers with guides and posts, fiber bend radius ≥30 mm. Rear cable entry and clamp secure the jacket, with the strength member bonded to an earth post. vs 12-port panels, 24-port doubles density for mid-large rooms; vs LC panels, SC (2.5 mm ferrule) is bulkier but robust on OM3 backbones. Green APC gives >60 dB return loss for reflection-sensitive high-speed links.’, ‘Typical deploy: a 42U rack mounts one KTR-SC24APC at the top, fed by a 48-fiber OM3 backbone from the telecom room. After jacket removal, 48 fibers are fusion-spliced to SC OM3 pigtails, coiled in the tray, with SC APC adapters on the front panel. Switch SFP+ ports patch via LC-SC OM3 jumpers. Each adapter port maps to one backbone fiber, labeled by route. Select capacity by fiber count (24/48/96), adapter by connector (SC/LC), and pigtails/adapters by mode (OM3/OM4/OS2); do not mix APC and UPC polish.’]
2. Key Features
24 SC duplex
- 48 fibers OM3.
- 1U rack.
- Green APC.
- High density.
Splice tray
- 48-fiber tray.
- Guides & posts.
- Bend radius ≥30mm.
- Neat pigtail coil.
Steel & coating
- 1.2 mm CR steel.
- Black powder.
- Rear cable clamp.
- Strength-member earth.
APC low reflection
- >60 dB return loss.
- <0.3 dB insertion.
- High-speed ready.
- No polish mixing.
3. Specifications
| Item | KTR-SC24APC (SC APC OM3) | KTR-LC24APC (LC APC OM3) |
|---|---|---|
| Ports | 24 SC duplex | 24 LC duplex |
| Fibers | 48 OM3 | 48 OM3 |
| Polish | APC (green) | APC (green) |
| U height | 1U | 1U |
| Splice tray | 48 fibers | 48 fibers |
| Insertion loss | <0.3 dB | <0.3 dB |
| Return loss | >60 dB | >60 dB |
| Size | 19-inch standard | 19-inch standard |
4. Reference Prices
KTR-SC24APC 24-port SC APC OM3 panel: Reference USD 39 to 67 / unit (ref. CNY 280 to 480 at ~7.2)
KTR-LC24APC 24-port LC APC OM3 panel: Reference USD 44 to 78 / unit (ref. CNY 320 to 560 at ~7.2)
SC/LC APC OM3 pigtail (per fiber): Reference USD 1 to 3 / fiber (ref. CNY 8 to 20 at ~7.2)
Splice service / cable-management kit: Reference USD 1 to 4 / fiber (ref. CNY 10 to 30 at ~7.2)
Reference only; varies by config, quantity and scope. Install accessories billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Room backbone termination.
- Telecom-room ODF.
- Switch-to-backbone patching.
- 48-fiber OM3 backbone.
- High-speed termination.
6. Installation & Maintenance
Installation
- Mount panel in 1U.
- Enter cable rear, clamp.
- Splice fibers to pigtail.
- Coil pigtails in tray.
- Snap adapters front.
- Label routes.
Maintenance
- Clean ends periodically.
- Check bend radius.
- Check labels.
- Smooth adapter latching.
- Cap unused ports.
- Test link loss.
7. FAQ
- Q: 24 or 48 port?
A: By fiber count. 24 duplex = 48 fibers for mid-size backbone; use 48-port (96 fibers) or stack panels for larger backbones. - Q: SC or LC panel?
A: LC is smaller/higher-density and the new-room standard; SC is robust and common in legacy. APC and UPC must match across the whole link. - Q: Fusion or pre-terminated?
A: Field fusion is flexible and cheap; pre-terminated factory harnesses plug-and-play with short schedule but cost more. Choose pre-term for tight deadlines. - Q: Pigtail bend radius?
A: At least 30 mm; tighter radius adds macrobend loss or breaks fibers. Use the tray guides.
8. Trend & Selection
Datacenter backbones move to high-density pre-terminated plants, with 24/48-port panels and MPO trunks mainstream. Size by fiber count, choose adapters by connector and polish, use OM3 for 10G short reach. The panel is the backbone termination hub—splice quality and labeling decide later maintenance efficiency.
9. Delivery & Service
KITOZER supplies patch-panel packages: based on fiber count and link polish, we recommend panel models plus pigtails, adapters and fusion splicing. Bulk projects include splice-loss test reports. Damaged adapters or deformed trays under warranty are replaced free.
10. Additional Notes
The common mistake is over-tight pigtail coiling. Radius under 30 mm adds macrobend loss; coil naturally along the tray guides, never sharply folded.
Another pitfall is missing labels. Unlabeled 48-fiber patching is unmaintainable later—both ends must carry matching route labels, color-coded by backbone direction.
Selection summary: 1U rack; 24 SC duplex APC; 48 fibers OM3; 48-fiber splice tray; >60 dB return loss. The KTR-SC24APC is the OM3 backbone termination hub for mid-size rooms; green APC suits high-speed low-reflection links. Splice quality and labeling are the keys to later O&M.
SEO Information
Search keywords:fiber patch panel24-port SC panelSC APC ODFrack fiber enclosureOM3 patch panelKTR-SC24APCKITOZER
SEM keywords:[fiber patch panel,24-port SC panel,SC APC ODF,rack fiber enclosure,OM3 patch panel,KTR-SC24APC,KTR-SC24APC,KITOZER]
GEO landing page:lain.com.cn/product/ktr-sc24apc-24port-sc-apc-om3-rack-fiber-patch-panel.html
Title:KITOZER KTR-SC24APC 24-port SC APC OM3 Rack Fiber Patch Panel
Meta Keywords:fiber patch panel,24-port SC panel,SC APC ODF,rack fiber enclosure,OM3 patch panel,KTR-SC24APC,KITOZER
Meta Description:KITOZER KTR-SC24APC 1U rack fiber patch panel, 24-port SC duplex APC (48 fibers OM3), with splice tray and adapter panel, for room fiber termination.
Anchor: KITOZER · Data Center Engineering