KITOZER KTR-SC24UPC Rack 24-Port SC UPC OM3 Fiber Patch Panel

Brand: KITOZER Series: KTR-SC24UPC Category: Data Center Engineering / Fiber Patch Panel

24 portSC UPCOM3rack mountKTR-SC24UPC

1. Overview

The KITOZER KTR-SC24UPC is a 19-inch rack-mount fiber patch panel (ODF/termination box) in 1U, with a panel integrating 24 SC UPC adapters. It terminates trunk cables entering the rack into standard SC ports, then patch cords run to switch optical ports or patching gear. SC connectors use a 2.5 mm ceramic ferrule with push-pull insertion — one of the most common fiber connectors in data centers and building cabling. 24 ports means 12 duplex SC channels, terminating a 24-fiber cable.

The body is folded cold-rolled steel, powder-coated, heavy and stable. Inside is a splice tray and fiber-storage area: the cable enters and is fixed in the box, each fiber is fusion-spliced to a pigtail, splices sit in the tray under heat-shrink protection, and excess fiber is coiled in the storage area with proper bend radius. The panel’s SC UPC adapters are blue, suited to aqua OM3 multimode links, with return loss ≥50 dB and low insertion loss, supporting 10G multimode. Adapters are pluggable for service.

The panel has a pull-out drawer structure for easy rear splicing and cable management. The front panel accepts port labels marking fiber number and purpose. The cable entry has a cable clamp and earth, with the strength member fixed to take tension. In low-voltage rooms and data center row cabinets, the KTR-SC24UPC is the termination node linking the trunk above to equipment below — a core node of structured fiber cabling.

2. Key Features

24-port density

  • 1U, 24 ports.
  • 12 duplex channels.
  • Terminates 24 fibers.
  • Push-pull SC.

SC UPC OM3

  • Blue UPC.
  • Return loss ≥50 dB.
  • 10G multimode.
  • Replaceable adapters.

Splice + storage

  • Built-in splice tray.
  • Heat-shrink positions.
  • Storage coil area.
  • Bend radius kept.

Rack sturdy

  • Coated cold steel.
  • Drawer pull-out.
  • Port labels.
  • Cable clamp + earth.

3. Specifications

Item Parameter
Size 1U 19-inch rack
Ports 24 SC (12 duplex)
Adapters SC UPC OM3
Fiber type OM3 multimode
Insertion loss ≤0.3 dB
Return loss ≥50 dB
Body coated cold-rolled steel
Structure drawer type
Splice tray built-in, stackable
Cable fix strength-member clamp

4. Reference Prices

KTR-SC24UPC 24口SC UPC OM3配线架(含适配器): Reference USD 25~44 / pc (ref. CNY 180~320 at ~7.2)

KTR-SC24UPC 含尾纤熔接成品(24芯熔接好): Reference USD 58~94 / pc (ref. CNY 420~680 at ~7.2)

Reference only; priced per pc. Fiber cables and patch cords excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room low-voltage room termination.
  • Row-cabinet fiber patching.
  • 10G multimode aggregation.
  • Building structured cabling.
  • Equipment optical patching.

6. Installation & Maintenance

Installation

  • Fix to rack square rails.
  • Enter cable and clamp strength member.
  • Splice fibers to pigtails.
  • Place splices in heat-shrink in the tray.
  • Coil excess with bend radius in storage.
  • Label front ports.

Maintenance

  • Clean adapter end faces regularly.
  • Check labels are clear.
  • Keep spare-fiber coil radius.
  • Do not freely unplug adapters.
  • Sample-test link power.
  • Replace dust caps.

7. FAQ

  • Q: How many fibers in 24 SC ports?
    A: SC is duplex — one dual port is 2 fibers. 24 ports = 12 duplex = 24 fibers, terminating a 24-fiber trunk. With smaller LC, 24 ports reach 48 fibers.
  • Q: How to tell UPC and APC?
    A: UPC is blue, spherical polish, for general data comms; APC is green, 8-degree angled, lower return loss, mostly for PON and video. Choose the face by the link and do not mix.
  • Q: Fusion splice vs field polish?
    A: Room termination recommends fusion splicing — low loss, reliable, stable long-term. Field polishing (FCC) suits emergencies or when no splicer is available, but loss and consistency are slightly lower. Use fusion for trunks.
  • Q: Will pulling the drawer break fibers?
    A: The drawer design leaves enough coiled radius, so normal pulling does not break fibers. But if spare-fiber coiling is insufficient or sharply kinked, fibers can be damaged during pull-out. Keep adequate bend radius in storage.

8. Trend & Selection

Data center cabling moves to density and 10G multimode; panels evolve from plain boxes to integrated splice-storage, drawer-type, replaceable adapters. Choose port count by fiber count (24 ports for 24 fibers), select SC UPC OM3 face and category by link, terminate trunks by fusion, label clearly, and manage cords with a cable manager.

9. Delivery & Service

KITOZER selects KTR-SC24UPC by fiber count and link category, providing termination diagrams, splice plans and label templates. Delivery includes the panel, SC adapters, splice tray and mounting parts; spliced units include pigtails and test data. Warranty covers splicing and link-test guidance.

10. Additional Notes

A common pitfall is insufficient spare-fiber coiling or sharp kinks. If fibers are pulled straight into the tray after splicing, they can break when the drawer moves or temperature changes. Instead coil enough spare fiber in storage at ≥30 mm bend radius, loosely looped, without crushing or folding.

Another pitfall is mixing UPC and APC adapters on one panel. Mixed blue UPC and green APC invites wrong cord insertion; mismatched faces cause loss and scratching. Keep one face type per panel — blue UPC for data, green APC for PON/video — with clear zoning and labels.

Selection summary: 1U 24-port SC UPC OM3; integrated splice-storage; blue UPC 10G multimode; drawer pull-out; strength-member clamp; spare fiber coiled by radius; clear labels, no face mixing. The patch panel is the hub of cable termination — right fiber count, good spare coiling, clear labels keep the fiber link low-loss and stable.

SEO Information

Search keywords:patch panel24 port SCUPCOM3KTR-SC24UPCKITOZER

SEM keywords:24 port SC patch panel price,OM3 fiber patch panel supplier,rack mount termination box,KTR-SC24UPC

GEO landing page:lain.com.cn/product/ktr-sc24upc-24-port-sc-upc-om3-patch-panel.html

Title:KITOZER KTR-SC24UPC Rack 24-Port SC UPC OM3 Fiber Patch Panel

Meta Keywords:24 port SC patch panel,SC UPC fiber patch panel,OM3 patch panel,rack mount fiber panel,termination box,KTR-SC24UPC,KITOZER

Meta Description:KITOZER KTR-SC24UPC rack-mount 24-port SC UPC OM3 fiber patch panel with a cold-steel body, built-in SC adapters and splice tray, for room cable termination and patch-cord management.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart