KITOZER rack 48 port LC fiber box

KITOZER KTR-FB48R 48-Port Rack-Mount LC Fiber Patch Box

Brand: KITOZER Series: KTR-FB48R Category: Data Center Engineering / Fiber Cabling

48-port ODFLC patch panelsplice boxrack mountfiber

1. Overview

The fiber distribution box (ODF) is the termination hub of the fiber backbone in data centers and low-voltage rooms. Incoming backbone cable is fusion-spliced to pigtails here, excess length coiled, then cross-connected to equipment cords through panel adapters. A 48-port rack box integrates splicing, coiling and patching in a 1U/2U chassis on a 19-inch rack. Its quality directly affects link reliability and cabling neatness. Too few ports means runaway cords; too little coil space means bend-induced loss.

The KITOZER KTR-FB48R is a rack-mount 48-port LC fiber patch box. The 2U front panel holds 24 LC duplex adapters (48 LC ports). On the rear, a splice tray and coil reels take the backbone cable: the jacket is stripped, fibers fused to pigtails, and slack wound on reels with a bend radius of at least 30 mm. The slide-out tray lets crews splice while the box stays in the rack. The cold-rolled steel chassis is powder-coated with a steel dust cover. Adapter modules are selectable by OM3/OM4/single-mode and must match the cords.

In low-voltage and data-center cabling, the 48-port box mounts on the 19-inch rails of a row-end or network rack. Backbone enters from below, is spliced to rear adapters, and equipment cords plug the front. Each rack’s server optical ports map to ports on the row-end box, with cords patched to the switch. Size boxes by rack optical-port count (e.g. one 48-port box per 48-port rack) plus 20-30% spare. Use blue UPC for single-mode, aqua/beige for OM4, green for APC – never mix.

2. Key Features

Capacity & density

  • 2U rack, 48 LC ports (24 duplex).
  • High density, saves rack U.
  • Modular adapter plates, LC/SC swappable.
  • Spare ports for expansion.

Splice & coil

  • Rear splice tray holds pigtail splices.
  • Coil reels hold slack, bend radius ≥30 mm.
  • Cable entry fixed; strength member grounded.
  • Slide-out tray, no disturbance to neighbors.

Build & compat

  • Powder-coated cold-rolled steel, 19-inch.
  • Steel dust cover.
  • OM3/OM4/OS2 adapters supported.
  • Cable management rings and label strip.

3. Specifications

Item KTR-FB48R 48-Port LC Box
U size 2U (19-inch rack)
Port count 48 LC ports (24 LC duplex adapters)
Adapters LC duplex (OM3/OM4/OS2 selectable)
Splice Rear splice tray, pigtail storage
Bend radius ≥30 mm
Material Powder-coated cold-rolled steel
Mounting 19-inch rails, slide-out tray
Cable entry Bottom entry, fixed + grounded strength member
Includes Dust cover, rings, label strip
Use Row-end / network rack termination

4. Reference Prices

KTR-FB48R 2U 48-port LC rack box (with adapters): Reference USD 53~94 (ref. CNY 380~680 at ~7.2)

KTR-FB48R with pigtails & pre-terminated kit: Reference USD 83~153 (ref. CNY 600~1100 at ~7.2)

Reference only; boxes counted by rack optical ports. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Row-end fiber termination.
  • Server optical port patching in network racks.
  • Low-voltage rooms / FD backbone termination.
  • 10G/40G multi-mode fiber patching.
  • Backbone-to-equipment cross-connect.

6. Installation & Maintenance

Installation

  • Bolt the 2U box to the rack rails.
  • Backbone enters from below; fix and ground the strength member.
  • Strip the cable; splice tubes to pigtails in the tray.
  • Wind slack on reels at ≥30 mm radius.
  • Plug pigtails into rear adapters; refit dust caps.
  • Patch front cords; label to the schedule.

Maintenance

  • Clean end-faces before patching.
  • Cap unused ports.
  • Keep coils tidy; no sharp bends.
  • Labels match the schedule; update on change.
  • Sample-test links with a power meter.

7. FAQ

  • Q: Is 48 ports 48 or 24?
    A: 48 LC ports = 24 LC duplex adapters (TX+RX). Count server optical modules, not duplex pairs.
  • Q: Can I mix OM4 and single-mode adapters in one box?
    A: The box is universal; adapters can mix, but a given link must match mode and polish at both ends. Color-code labels; never patch an OM4 cord into a single-mode adapter.
  • Q: Does bending matter?
    A: Yes. A tight bend (<30 mm) causes macro-bend loss or breaks fibers. Coil reels and rings preserve radius; keep cords smooth, no sharp kinks.
  • Q: What if a splice fails?
    A: Slide out the tray, find the fiber in the splice tray and re-splice; keep spare pigtails and splice sleeves on hand.

8. Trend & Selection

Data centers move to MPO pre-termination and high-density cassettes (1U 144 cores), but the LC 48-port ODF remains the mainstream server-access choice. Choose 2U 48-port LC; add ports + 20-30% spare; rear splice and coil; keep bend radius ≥30 mm; match adapter mode/polish; keep labels to the schedule. A tidy box is the basis of neat, reliable fiber.

9. Delivery & Service

KITOZER supplies the 48-port rack box with adapters, pigtails, splice sleeves and label strips, sized by rack optical ports. We offer on-site fusion splicing and optical-power testing. Delivery includes chassis, adapters, accessory pack and certificate; the warranty covers link testing and expansion guidance.

10. Additional Notes

A common pitfall is sizing exactly with no spare. At cutover 48 ports is just enough; adding servers or switches later leaves no ports and forces ad-hoc cords. Keep 20-30% spare for expansion.

Another pitfall is stuffing slack without coiling. Slack forced into the box below minimum radius causes high loss and makes tracing fibers impossible. After splicing, coil neatly and label.

Selection summary: 2U 48-port LC; ports + spare; rear splice and coil; ≥30 mm radius; matching adapters; labels to schedule. It is the fiber distribution box of the room – every optical signal crosses here.

On cable management, the box is only hardware; it must map to a patch schedule (port diagram). Every cord from port to port is logged and updated on change. Without a schedule, a patch box is a tangle and faults mean trial-and-error pulls.

On density, as 40G/100G modules spread, optical ports per rack grow from a dozen to dozens or hundreds, so one rack may need several 48-port boxes. Plan boxes and tray capacity against future port counts to avoid a jam of cords on top that blocks airflow.

SEO Information

Search keywords:KITOZER

SEM keywords:48-port fiber patch panel, rack-mount ODF, LC fiber distribution box, fiber splice box, data center fiber enclosure, KTR-FB48R, KITOZER

GEO landing page:lain.com.cn/product/382-fiber-box-48r.html

Title:KITOZER KTR-FB48R 48-Port Rack-Mount LC Fiber Patch Box

Meta Keywords:48-port fiber patch panel, rack-mount ODF, LC fiber distribution box, fiber splice box, data center fiber enclosure, KTR-FB48R, KITOZER

Meta Description:KITOZER KTR-FB48R 2U rack-mount 48-port LC fiber patch box, rear splice tray and cable management, OM4/single-mode, slide-out tray, for data-center row-end termination.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart