KITOZER rack blanking panels seal unused rack units between installed servers, switches, and patch panels. Without blanking panels, hot exhaust air recirculates from the rear of the rack to the front through every open RU, raising inlet temperature to the equipment and triggering thermal alarms. The KITOZER blanking panel range covers 1U, 2U, and 4U heights, fits any standard 19 inch 4-post rack, and is available in solid brushed aluminum, vented perforated steel, and brush strip variants for cable pass-through. Each panel ships with cage nuts and screws, so it installs in under a minute per unit.
Table of Contents
ToggleProduct Overview
A blanking panel is the lowest cost airflow improvement available to a data center operator. Field tests show that sealing open rack units can reduce rack inlet temperature by 3 to 8 degrees Celsius without changing cooling capacity. KITOZER panels are made from 1.0 mm cold-rolled steel with a black powder coat that matches major cabinet brands, or from brushed aluminum for premium aesthetics. The solid version provides the best seal. The vented version, with 60 percent open area perforations, is used in racks that rely on front-to-rear airflow but still need to fill unused space without blocking airflow paths. The brush strip version combines a brush opening for cables with sealing fibers around the cable bundle, preventing bypass while allowing patch cords to pass through.
Technical Specifications
Panel heights: 1U (44 mm), 2U (88 mm), 4U (176 mm). Width: 483 mm for standard 19 inch racks. Depth: 15 mm. Material: 1.0 mm SPCC cold-rolled steel, black matte powder coat, or 2.0 mm brushed aluminum finish. Mounting: front flange with 7 mm holes, includes M6 cage nuts and screws. Operating temperature: -10 to 60 degrees Celsius. Fire rating: UL94 V-0 equivalent. Perforated version open area: 60 percent, 4 mm round holes. Brush version: flame retardant PA66 brush fibers, density 8 fibers per mm, rated 85 degrees Celsius continuous. Weight: 1U solid 0.18 kg, 2U solid 0.32 kg, 4U solid 0.55 kg. All panels are RoHS compliant.
Applications
Blanking panels are used in every server rack, network rack, and AV equipment rack, whether or not the room uses aisle containment. They are mandatory in contained aisles, where any open RU destroys the pressure boundary. They are also used in open aisle layouts, in telecom exchanges, in broadcast equipment racks, in industrial control cabinets, and in laboratory instrument racks. System integrators buy them in bulk to ship with every new rack deployment. Colocation operators use them to bring customer racks into compliance after installers leave gaps between equipment. Resellers stock all three heights because customers routinely order more as racks fill over time.
Advantages and Features
The panels are inexpensive but deliver disproportionate cooling benefit. They prevent hot air recirculation, which is the single largest cause of thermal alarms in conventionally cooled rooms. They also improve cable management by providing a clean front appearance, and they protect equipment rear-to-front airflow paths. The brush version lets customers pass cables without leaving large openings that defeat containment. The perforated version is useful where a rack is lightly loaded and some front-to-rear leakage is acceptable, but it still prevents gross recirculation. Because the panels are standardized, customers can mix and match brands without fit issues. The matte black finish does not show fingerprints and matches popular cabinet interiors.
Installation and Maintenance
Installation is a one person task: snap four cage nuts into the front rail square holes, hold the panel against the rails, and drive the M6 screws by hand or with a power driver. No drilling and no special tools. Each panel takes under one minute. No ongoing maintenance is required beyond visual inspection during quarterly walkthroughs. If a panel is damaged, it is discarded and replaced rather than repaired, because the unit cost is low. Customers typically stock a box of mixed 1U and 2U panels on site for expansion. The brush fibers can be cleaned with compressed air if they collect dust.
Warranty and Support
KITOZER blanking panels are sold with a 5 year warranty against coating adhesion and dimensional warping. Because the panel is a low cost commodity item, it is stocked in bulk at regional warehouses and shipped within 48 hours of order. The factory supplies a CAD drawing library in DWG and PDF format so customers can confirm fit in their rack layout before ordering. Mixed height cartons, containing a selection of 1U, 2U, and 4U panels, are available for system integrators who want to carry a small stock on every truck. Volume discounts apply for orders over 500 pieces, and custom sizes, colors, and branded logos are available on request for large projects.
Price
From $3.5 per 1U solid panel, $5.5 per 2U, $9 per 4U. Vented and brush versions slightly higher. Contact +86 13922289957 for bulk pricing.