KITOZER Rack UPS: 2kVA Online For Small Server Rack

KITOZER 2kVA rack online double conversion UPS delivers conditioned, uninterruptible power for small business server racks containing 1U and 2U servers, SAN storage, and network switching gear. The unit is built around a high-frequency PWM rectifier and IGBT inverter that together produce a pure sine wave output with less than 3% total harmonic voltage distortion. This makes it safe for all sensitive electronic loads including active PFC power supplies found in modern servers.

Product Overview

Housed in a 3U rack-mountable chassis, the 2kVA UPS converts between rack and tower orientation in minutes using included slide rails and support stands. A large graphical LCD on the front panel displays input, output, battery, load, and temperature data in real time, while four status LEDs indicate normal, battery, fault, and bypass conditions. The unit supports USB, RS232, SNMP card slot, and dry contact relay ports, allowing integration with virtually any monitoring ecosystem. An integrated maintenance bypass is optional and recommended for installations where planned servicing of the UPS cannot interrupt the load.

Technical Specifications

Rated 2kVA / 1.8kW, output power factor 0.9. Input 220-240VAC, range 110-300VAC, power factor correction >0.99. Output 230VAC, regulation +/-1%, THDv <3% linear load. Inverter efficiency 93%, ECO mode 98%. Internal VRLA 12V 9Ah x 4, standard backup 6-10 minutes at full load. Recharge to 90% in 4 hours. Battery test automatic every 7 days. Operating temperature 0-40C, noise <50dBA. Dimensions 438 x 530 x 132mm (3U), weight 32kg. CE, ISO 9001 certified. KITOZER, 3 year warranty.

Application Scenarios

Typical deployments include small data centers with 3-5 rack servers, virtualization hosts, storage arrays, and core network switches. The unit also protects medical imaging peripherals, industrial SCADA workstations, broadcast studio editing bays, and retail data consolidation racks. When paired with KITOZER external battery cabinets, runtime can extend to 30 minutes or longer for orderly shutdown or generator bridging.

Advantages and Features

True online double conversion ensures zero transfer time even during long brownouts. Active input power factor correction reduces upstream current distortion and lowers utility demand charges. The intelligent battery management system compensates charging voltage for temperature and runs periodic capacity tests, doubling battery life compared with uncontrolled chargers. Hot-swappable battery packs mean battery replacement can be performed live without opening the rack power distribution.

Installation and Maintenance Advice

Mount the UPS on reinforced rack rails rated for at least 50kg. Keep clearances of 50mm on each side and 100mm at the rear for airflow. Use appropriately rated rack PDU to distribute output to loads. Configure the SNMP card with the site NTP server and alert email recipients during commissioning. Perform quarterly visual inspection of fans and filters, annual load bank test, and battery replacement at 3-5 year intervals. Document every battery replacement and firmware update in the on-site maintenance log.