KITOZER Rack UPS: 3kVA Online Double Conversion Long Backup

KITOZER 3kVA rack online double conversion UPS is a workhorse for mid-size business IT rooms, virtualization hosts, and network core racks that require clean sine wave power and extended battery runtime. The high-frequency topology continuously conditions utility power, isolating critical loads from surges, sags, impulses, noise, and frequency deviations. With output power factor 0.9, the unit delivers 2.7kW of real power, comfortably supporting dense blade servers and storage controllers. The unit is suitable for installations where both rack space and floor space are at a premium.

Product Overview

The unit supports both rack and tower deployment. The front LCD provides real-time power quality data including THD and power factor. The smart slot accepts SNMP, Modbus, or dry-contact cards.

The 3kVA model fits a 4U rack chassis and can be deployed horizontally in a 19-inch rack or vertically as a tower using the included conversion kit. A backlit LCD shows real-time input, output, load bar, battery state of charge, and event history. The unit ships standard with USB and RS232 ports and a smart slot for an optional SNMP card. An isolated relay contact board provides dry contacts for remote building management alarms. The smart battery charger supports unlimited parallel external battery cabinets, enabling runtime configurations from 15 minutes to several hours. The front panel includes a protective door and lock to prevent unauthorized access.

Technical Specifications

Rated 3kVA / 2.7kW. Input 220-240VAC, range 110-300VAC, PFC greater than 0.99, inrush current limited. Output 230VAC pure sine, regulation plus or minus 1 percent, THDv less than 2 percent linear, less than 5 percent non-linear. Inverter efficiency 94 percent, ECO 98 percent. Internal VRLA 12V 9Ah x 6, runtime 6-10 min full load. Charging current adjustable 1-10A. Operating temperature 0-40C, noise less than 55dBA. Dimensions 438 x 620 x 176mm (4U), weight 48kg. Output sockets 10 x IEC C13 plus hard-wired terminal. CE, ISO. KITOZER, 3 year warranty, 2 year battery warranty.

Application Scenarios

In healthcare facilities, the unit protects medical imaging peripherals and laboratory equipment. The isolated outlet group allows sequential shutdown of non-critical devices first, preserving runtime for critical servers.

The unit is also suitable for edge colocation facilities where multiple tenants share a common power feed, and for small government offices requiring clean power for secure communications equipment. When configured with external battery cabinets, it supports 1-2 hour runtime for critical systems during extended outages.

This UPS is commonly specified for corporate server rooms running VMware or Hyper-V clusters, database servers, VoIP PBX systems, and central storage arrays. It is also used in manufacturing execution systems, broadcast playout servers, security operations centers, and banking branch communications. For sites with a backup generator, the 3kVA unit bridges the gap between utility failure and generator pickup, typically 10-30 seconds, eliminating any perceived outage. External battery cabinets extend runtime to cover graceful virtual machine migration or orderly shutdown. The tower option suits floor-standing installations in rooms without reinforced rack structures.

Advantages and Features

The unit supports Modbus RTU via RS485 for integration with industrial SCADA systems. The Web HMI provides real-time power quality data and historical trending. Remote firmware upgrade reduces service visits.

The unit also supports scheduled battery testing that runs automatically during off-peak hours, and the event log stores the last 500 alarms for post-incident analysis. The Web HMI allows remote configuration from any browser, reducing truck rolls for routine settings changes.

Double conversion online topology delivers zero transfer time and output power factor 0.9 for today power-dense IT loads. Wide input window reduces battery wear. The intelligent charger adapts charge current to battery capacity and temperature, preventing overcharge and thermal runaway. Parallel capability supports N+1 redundancy when two units are installed. Remote management via SNMP Web interface provides email, SMS, and trap alerts for proactive service. The unit also supports scheduled battery test and automatic shutdown of connected servers. ECO mode achieves 98 percent efficiency for stable mains.

Installation and Maintenance Advice

Keep spare fuses and a spare battery module on site. Document all configuration changes. Verify shutdown software triggers graceful server shutdown.

Keep spare batteries on site matching the installed string. Document all configuration changes in the site runbook. Verify that the shutdown software is configured for graceful shutdown of all connected servers before the battery reaches low-voltage cutoff.

Plan rack weight carefully, as the 48kg UPS plus external battery cabinets may require reinforced shelves. Keep ambient below 25C to achieve the rated battery service life of 5 years. Cable external battery cabinets with sized copper conductors and fuse protection at the battery end. Test the automatic shutdown software during commissioning by simulating a utility failure. Schedule battery capacity test every 12 months, and replace batteries when measured runtime falls below 80 percent of rated. Keep spare fuses and a spare battery module on site. Inspect cooling fans quarterly.