KITOZER Rack UPS: 3kVA Online Double Conversion Long Backup

KITOZER 3kVA rack online double conversion UPS is a workhorse for mid-size business IT rooms, virtualization hosts, and network core racks that require clean sine wave power and extended battery runtime. The high-frequency topology continuously conditions utility power, isolating critical loads from surges, sags, impulses, noise, and frequency deviations. With output power factor 0.9, the unit delivers 2.7kW of real power, comfortably supporting dense blade servers and storage controllers.

Product Overview

The 3kVA model fits a 4U rack chassis and can be deployed horizontally in a 19-inch rack or vertically as a tower using the included conversion kit. A backlit LCD shows real-time input, output, load bar, battery state of charge, and event history. The unit ships standard with USB and RS232 ports and a smart slot for an optional SNMP/Modbus TCP card. An isolated relay contact board provides dry contacts for remote building management alarms. The smart battery charger supports unlimited parallel external battery cabinets, enabling runtime configurations from 15 minutes to several hours.

Technical Specifications

Rated 3kVA / 2.7kW. Input 220-240VAC, range 110-300VAC, PFC >0.99, inrush current limited. Output pure sine 230VAC, regulation +/-1%, THDv <2% linear, <5% non-linear. Inverter efficiency 94%, ECO 98%. Internal VRLA 12V 9Ah x 6, runtime 6-10 min at full load. Charging current adjustable 1-10A. Operating temperature 0-40C, noise <55dBA. Dimensions 438 x 620 x 176mm (4U), weight 48kg. CE, ISO. KITOZER, 3 year warranty, 2 year battery warranty.

Application Scenarios

This UPS is commonly specified for corporate server rooms running VMware or Hyper-V clusters, database servers, VoIP PBX systems, and central storage arrays. It is also used in manufacturing execution systems, broadcast playout servers, security operations centers, and banking branch communications. For sites with a backup generator, the 3kVA unit bridges the gap between utility failure and generator pickup, typically 10-30 seconds, eliminating any perceived outage.

Advantages and Features

Double conversion online topology delivers zero transfer time and output power factor 0.9 for today power-dense IT loads. Wide input window reduces battery wear. The intelligent charger adapts charge current to battery capacity and temperature, preventing overcharge and thermal runaway. Parallel capability supports N+1 redundancy when two units are installed. Remote management via SNMP Web interface provides email, SMS, and trap alerts for proactive service.

Installation and Maintenance Advice

Plan rack weight carefully, as the 48kg UPS plus external battery cabinets may require reinforced shelves. Keep ambient below 25C to achieve the rated battery service life of 5 years. Cable external battery cabinets with sized copper conductors and fuse protection at the battery end. Test the automatic shutdown software during commissioning by simulating a utility failure. Schedule battery capacity test every 12 months, and replace batteries when measured runtime falls below 80% of rated.

Price

From $1,480/pc. Contact +86 13922289957 for 3kVA rack UPS pricing, external battery cabinet sizing, and generator bridging runtime calculations.