Table of Contents
ToggleProduct Overview
The KITOZER Rackmount UPS 2kVA delivers 2000VA and 1800W of online double-conversion power in a compact 2U chassis that converts to tower form factor when needed. Designed for small server rooms, network core switches, storage arrays, and mid-size security systems, this unit provides clean regulated power and instant battery backup during utility failures. The convertible rack-to-tower design gives integrators flexibility when deploying in different cabinet or closet environments.
Built for 24/7 mission-critical operation, the KITOZER unit uses transformer-less high-frequency topology with IGBT inverter technology and digital signal processor control for precise output voltage and frequency regulation. The wide input voltage window allows the UPS to ride through deep sags and swells without switching to battery, extending battery life and reducing cycling. Input power factor correction greater than 0.99 and total harmonic distortion less than 3 percent help the site comply with IEEE 519 requirements and avoid utility penalty charges. The unit is CE certified and complies with IEC 62040 safety and EMC standards for global deployment.
Intelligent battery management performs periodic self-tests every 30 days, monitors cell voltage, charge current, and ambient temperature, and compensates charge voltage to maximize battery service life. The front panel color LCD displays real-time input voltage, output voltage, load percentage, battery capacity, temperature, and active alarms, rotating automatically for rack or tower orientation. Optional SNMP and Modbus TCP integration fits DCIM, building management, and NMS platforms for remote alarm email, scheduled shutdown, and historical logging. Three-year standard warranty with optional extended coverage available from KITOZER factory.
Technical Specifications
Input range 110 to 300VAC full load, frequency 40 to 70Hz. Output 230VAC plus or minus 2 percent, power factor 0.9, online efficiency 91 percent. Six C13 and one C19 output sockets. Up to four external battery packs for 1 to 4 hours backup. Dimensions 438 by 440 by 86 mm, weight 18 kg.
Input power factor greater than 0.99, total harmonic distortion less than 3 percent, online efficiency optimized for low operating cost and reduced cooling load. Output voltage regulation within plus or minus 1 percent ensures clean power for sensitive IT loads and industrial control equipment. Overload rating supports motor inrush currents and transient events. Operating temperature 0 to 40 degrees Celsius, relative humidity 5 to 95 percent non-condensing. Event log stores up to 512 records for troubleshooting and compliance reporting. Color LCD with backlight and intuitive menu navigation for daily operation.
Application Scenarios
Typical deployments include SMB server rooms with rack servers, VoIP phone systems, core routers and firewalls, NVR and CCTV storage, industrial workstations, and hotel reservation terminals. The long backup option is frequently chosen for sites where a generator is not installed.
Additional use cases include government back-office systems, media editing workstations, security operations centers, university computer labs, and small manufacturing work cells. The wide input voltage range allows deployment in regions with unstable grid voltage where line-interactive units would constantly switch to battery. The pure sine-wave output is safe for active PFC power supplies found in modern servers, storage arrays, and high-end network appliances. External battery cabinets are chosen when generator start-up time is long or not available, ensuring orderly shutdown of virtualization clusters and critical workloads.
Key Advantages
Wide 110 to 300V input window lets the UPS ride through deep sags without draining batteries. Parallel external battery packs scale runtime linearly. AS400 dry contact supports legacy server shutdown signaling.
Built-in surge and EMI filtering protects connected equipment from lightning transients and conducted noise. Compact design saves valuable rack or floor space in data center and IT room environments. Hot-swappable batteries allow replacement without powering down the load, reducing service time to minutes. The optional SNMP card integrates with existing DCIM and BMS platforms without additional hardware cost. Comprehensive event log and waveform capture simplify troubleshooting for maintenance teams and reduce mean time to repair.
Installation and Maintenance Advice
Use the included rail kit for rack mounting or the tower feet for floor placement. Provide at least 1U clearance for airflow.
Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life and optimal UPS performance. Download the KITOZER PowerShut software for graceful shutdown of connected servers during extended outages. Perform a full discharge test every 6 months to verify runtime and battery health. Recharge batteries for 8 hours after installation or replacement. Update firmware via USB in maintenance window and keep the event log exported before upgrades. Keep spare fans and fuses on site for fast replacement. Label bypass positions and emergency stop buttons clearly for maintenance teams.
Price
From $690 per unit. External battery packs, SNMP card, and extended warranty quoted separately.
KITOZER provides comprehensive technical support including pre-sales consultation, system design guidance, factory training, and on-site commissioning assistance. Spare parts inventory is maintained for fast shipment worldwide. Extended warranty plans are available for mission-critical installations. Contact KITOZER engineering team for custom configurations, high-altitude derating, and specific application requirements.