KITOZER
KITOZER

KITOZER Rackmount UPS 3kVA 2U Online Double Conversion

Product Overview

The KITOZER Rackmount UPS 3kVA is a high-density 2U online UPS delivering 3000VA and 2700W for IT racks, network core infrastructure, and edge data centers. With power factor 0.9 and a true double-conversion topology, it powers modern servers with active PFC power supplies without risk of overload. The compact 2U height leaves valuable rack space for servers and switches, while the internal battery set provides enough autonomy for graceful shutdown and generator takeover.

Built for 24/7 mission-critical operation, the KITOZER unit uses transformer-less high-frequency topology with IGBT inverter technology and digital signal processor control for precise output voltage and frequency regulation. The wide input voltage window allows the UPS to ride through deep sags and swells without switching to battery, extending battery life and reducing cycling. Input power factor correction greater than 0.99 and total harmonic distortion less than 3 percent help the site comply with IEEE 519 requirements and avoid utility penalty charges. The unit is CE certified and complies with IEC 62040 safety and EMC standards.

Intelligent battery management performs periodic self-tests every 30 days, monitors cell voltage, charge current, and ambient temperature, and compensates charge voltage to maximize battery service life. The front panel color LCD displays real-time input voltage, output voltage, load percentage, battery capacity, temperature, and active alarms, rotating automatically for rack or tower orientation. Optional SNMP and Modbus TCP integration fits DCIM, building management, and NMS platforms for remote alarm email, scheduled shutdown, and historical logging. Three-year standard warranty with optional extended coverage.

Technical Specifications

Input range 110 to 300VAC, frequency 40 to 70Hz. Output 200 to 240VAC selectable, power factor 0.9, online efficiency 92 percent. 8 C13 and 2 C19 output sockets. Up to 4 external battery packs. Parallel up to 3 units. Dimensions 438 by 620 by 86 mm, weight 28 kg.

Input power factor greater than 0.99, total harmonic distortion less than 3 percent, online efficiency optimized for low operating cost. Output voltage regulation within plus or minus 1 percent ensures clean power for sensitive IT loads. Overload rating supports motor and inrush currents. Operating temperature 0 to 40 degrees Celsius, relative humidity 5 to 95 percent non-condensing. Event log stores up to 512 or 1024 records for troubleshooting. Color LCD with backlight and intuitive menu navigation.

Application Scenarios

Deploy this UPS in medium IT closets, retail data rooms, branch offices of banks, hospital imaging suites, industrial SCADA control rooms, and distributed edge computing nodes. It powers high-density rack servers, blade enclosures, SAN storage, and core routers.

Additional use cases include government back-office systems, media editing workstations, security operations centers, university computer labs, and small manufacturing work cells. The wide input voltage range allows deployment in regions with unstable grid voltage where line-interactive units would constantly switch to battery. The pure sine-wave output is safe for active PFC power supplies found in modern servers, storage arrays, and high-end network appliances. External battery cabinets are chosen when generator start-up time is long or not available.

Key Advantages

Power factor 0.9 means 2700W real output from a 3kVA frame, matching modern server power supplies. Parallel N+1 option provides redundancy without a separate STS. Built-in energy meter supports sustainability reporting.

Built-in surge and EMI filtering protects connected equipment from lightning transients and conducted noise. Compact design saves valuable rack or floor space. Hot-swappable batteries allow replacement without powering down the load, reducing service time to minutes. The optional SNMP card integrates with existing DCIM and BMS platforms without additional hardware. Comprehensive event log and waveform capture simplify troubleshooting for maintenance teams.

Installation and Maintenance Advice

Use heavy-duty rails rated for 28 kg. Provide dedicated 16A circuit and hardwired input. For parallel N+1, use the KITOZER parallel cable kit and ensure identical firmware.

Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life. Download the KITOZER PowerShut software for graceful shutdown of connected servers during extended outages. Perform a full discharge test every 6 months to verify runtime. Recharge batteries for 8 hours after installation or replacement. Update firmware via USB in maintenance window and keep the event log exported before upgrades. Keep spare fans and fuses on site for fast replacement.

Price

From $1,050 per unit. Parallel kit, external battery packs, SNMP card, and extended warranty quoted separately.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart