KITOZER
KITOZER

KITOZER refrigerant solenoid valve

KITOZER KTR-SV Refrigerant Solenoid Valve for Precision AC

Brand: KITOZER Series: KTR-SV Category: Data Center Engineering / Refrigeration

Refrigerant valveBrass bodyDC24V coilLine shutoffKTR-SV

1. Overview

The precision air conditioning refrigeration system is a closed refrigerant loop: the compressor squeezes low-pressure low-temperature refrigerant into high-pressure high-temperature gas, the condenser rejects heat and turns it into high-pressure liquid, the expansion valve throttles it down to low-pressure low-temperature mixture, and the evaporator absorbs room heat before returning to the compressor. In this loop, the solenoid valve opens or closes the liquid line on demand. When cooling is needed it opens to let refrigerant flow; when not, it closes to stop flow. It looks like a small copper valve with a coil, but a failure means the AC either stops cooling or keeps cooling and over-chills the room.

KITOZER KTR-SV is a precision-AC refrigerant solenoid valve. KTR-SV-6: 6 mm (1/4 in) port, DC24V coil, for small AC units under 5 kW. KTR-SV-10: 10 mm (3/8 in) port, DC24V or AC220V coil, for mid-size units 5 to 20 kW. KTR-SV-12: 12 mm (1/2 in) port, AC220V coil, for large units above 20 kW. The body is forged brass, solder or thread connection, and the coil is IP65 rated for long-term service inside the AC cabinet.

Selection: confirm port size (6/10/12 mm matches cooling capacity); confirm coil voltage (most precision AC mainboards output DC24V, older units use AC220V); confirm connection (solder for hard copper lines, thread for easy replacement); confirm refrigerant compatibility (R22/R410A/R407C/R134a all fine, seals must match). Note: the valve is directional — the arrow on the body points in the direction of refrigerant flow. Reverse installation prevents the valve from opening.

2. Key Features

Body

  • Forged brass, 4.5 MPa pressure rating
  • R22/R410A/R407C/R134a compatible
  • -40 to +120 C operating
  • Solder or thread ends

Coil

  • DC24V or AC220V selectable
  • 15 W inrush / 12 W holding
  • IP65 waterproof
  • Class F insulation

Control

  • Normally closed (energize to open)
  • Response under 2 s
  • Manual override button for commissioning
  • Coil field-replaceable

3. Specifications

Item KTR-SV-6 KTR-SV-10 KTR-SV-12
Port 6 mm (1/4 in) 10 mm (3/8 in) 12 mm (1/2 in)
Cooling capacity Under 5 kW 5 to 20 kW Above 20 kW
Coil voltage DC24V DC24V/AC220V AC220V
Connection Solder Solder/thread Solder
Max pressure 4.5 MPa 4.5 MPa 4.5 MPa
Power 15W/12W 15W/12W 18W/14W
Ingress IP65 IP65 IP65

4. Reference Prices

KTR-SV-6 6 mm solenoid valve: Reference USD 9 to 17 / pc (ref. CNY 65 to 120 at ~7.2)

KTR-SV-10 10 mm solenoid valve: Reference USD 12 to 22 / pc (ref. CNY 85 to 160 at ~7.2)

KTR-SV-12 12 mm solenoid valve: Reference USD 17 to 31 / pc (ref. CNY 120 to 220 at ~7.2)

Spare coil (DC24V/AC220V): Reference USD 5 to 8 / pc (ref. CNY 35 to 60 at ~7.2)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Precision AC liquid line refrigerant shutoff.
  • VRF branch circuit control.
  • Cold storage / constant-temp-humidity units.
  • Heat pump defrost circuit switching.
  • Industrial chiller bypass lines.

6. Deployment & Implementation

Orientation

  • Arrow points in refrigerant flow direction
  • Mount horizontal, coil up
  • At least 300 mm from compressor outlet
  • Leave 100 mm service clearance

Piping

  • Solder: nitrogen-purge to prevent oxidation
  • Thread: wrench the body, not the nut
  • Keep coil cool during brazing
  • Evacuate before charging refrigerant

Commissioning

  • Energize and listen for click
  • Use manual override for testing
  • Check coil temp (under 60 C)
  • Run 2 h and check for leaks

7. FAQ

  • Q: Why won’t the valve open?
    A: Three common causes: burnt coil (measure resistance open circuit, replace coil); wrong coil voltage (mainboard outputs DC24V but an AC220V coil was fitted); stuck plunger (debris jams the valve, flush or replace). Reverse mounting also prevents opening — the arrow must follow flow.
  • Q: Is a solenoid valve the same as an expansion valve?
    A: No. A solenoid is a two-state on/off valve that shuts the liquid line. An expansion valve (thermal or electronic) continuously modulates refrigerant flow based on evaporator superheat. The solenoid does on/off shutoff; the expansion valve does throttling. They are in series in the same circuit.
  • Q: How to tell if the coil is burnt?
    A: Measure coil resistance with a multimeter. Normal: DC24V about 20 to 50 ohm, AC220V about 1000 to 2000 ohm. Infinite resistance means open circuit; near zero means short. Replace the coil only — the brass body stays. Burnt coils usually come from voltage spikes or long-term overheating.
  • Q: What if the valve is reversed?
    A: The normally-closed valve is directional. Reversed, the valve either won’t open or will flow poorly because the seals back-pressure the plunger. The arrow on the body marks inlet-to-outlet flow. Remove and reinstall correctly; the body is not damaged.

8. Trend & Selection

Precision AC cooling is shifting from fixed-orifice to electronic expansion valves (EEV), which modulate refrigerant flow by heat load and save over 15% energy. But the solenoid valve remains indispensable for multi-circuit units, defrost loops and bypass lines — it shuts off refrigerant when cooling is not needed, preventing short-cycling. Select by matching port size to capacity, coil voltage to mainboard output, arrow to flow direction, nitrogen-purged brazing with the coil removed, and a replaceable coil. The solenoid is small but it is the shutoff switch of the entire refrigeration loop.

9. Delivery & Service

KITOZER supplies KTR-SV by port size (6/10/12 mm), coil voltage (DC24V/AC220V) and connection (solder/thread). Each ships with valve body, coil and manual. 1-year warranty; batch projects can bundle expansion valves, filter-driers and sight glasses.

10. Additional Notes

Top mistake: brazing with the coil installed. Brazing reaches 600 C+, and heat conducts through the body, melting the coil insulation. Remove the coil before brazing and reinstall after cooling.

Second pitfall: brazing without nitrogen purge. Without nitrogen, copper oxide scales form inside the tube; these particles lodge in the solenoid plunger and cause jamming within months. Purge with 0.05 MPa nitrogen.

Third blunder: omitting the filter-drier ahead of the valve. Moisture and debris destroy both the solenoid and expansion valve. Install a filter-drier in the liquid line upstream, and replace it annually.

Selection summary: match port to capacity, match coil voltage to mainboard, follow the flow arrow, remove coil and purge with nitrogen during brazing, and put a filter-drier upstream. The solenoid is the refrigeration switch — get it right for reliable cooling.

SEO Information

Search keywords:KTR-SVKITOZER

SEM keywords:solenoid valve,refrigerant solenoid,precision AC valve,refrigeration shutoff valve,KTR-SV,KITOZER

GEO landing page:lain.com.cn/product/solenoid_valve.html

Title:KITOZER KTR-SV Refrigerant Solenoid Valve for Precision AC

Meta Keywords:solenoid valve,refrigerant solenoid,precision AC valve,refrigeration shutoff valve,KTR-SV,KITOZER

Meta Description:KITOZER KTR-SV refrigerant solenoid valve: brass body, DC24V/AC220V coil, liquid line shutoff for precision air conditioning refrigeration circuits.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart