Table of Contents
ToggleKITOZER KTR-SH3 Heavy-Duty 19-inch Rack Shelf
Brand: KITOZER Series: KTR-SH3 Category: Data Center Engineering / Rack Accessories
rack shelf19 inchheavy dutytraycold aisle rack
1. Overview
Not every device mounts directly to rack rails: units without rack ears (desktop switches, small UPS, routers, disk arrays) need a shelf. The shelf bolts to the 19-inch square-hole rails, giving a horizontal plane; the device sits on it and is screwed or strapped down. A fixed shelf differs from a sliding one: simpler, stronger, cheaper — good for units that stay put.
The KITOZER KTR-SH3 is a heavy-duty 19-inch fixed shelf. SPCC cold-rolled steel, electrostatic powder coating, front folded-edge reinforcement, load ≥50kg. Depths by cabinet (e.g. 600/800mm), width fits 19-inch rails with mounting ears and square holes, M6 cage nuts and screws included. Ventilated holes aid airflow; front edge has wiring/device-mounting holes.
In modular cold-aisle racks, KTR-SH3 supports non-rack-form-factor gear, using the enclosed cabinet space fully. Plan shelf height by device U-position, leaving room for cooling and cabling. Though an accessory, it affects mounting stability and airflow — too deep blocks the blanking-panel path; too shallow gives poor support.
2. Key Features
Load & build
- SPCC cold-rolled steel.
- Folded-edge, load ≥50kg.
- Powder-coated, wear resistant.
- Thick front edge resists sag.
Fit
- Fits 19-inch rails.
- M6 cage nuts/screws.
- 600/800mm depths.
- Adjustable front/rear ears.
Vent & cable
- Perforated vent array.
- Front wiring/mount holes.
- Smooth edges.
- Pairs with blanking panels.
3. Specifications
| Item | KTR-SH3 |
|---|---|
| 适配机架 | 19英寸 |
| 材质 | SPCC冷轧钢板 |
| 承重 | ≥50 kg |
| 深度 | 600/800 mm(可选) |
| 表面 | 静电喷塑 |
| 安装 | 方孔条 M6 |
| 散热孔 | 有 |
| 颜色 | 黑色/灰白 |
4. Reference Prices
KTR-SH3 heavy-duty 19-inch shelf (600mm deep): Reference USD 11~25 (ref. CNY 80~180 at ~7.2)
Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Non-rack switches/routers.
- Small UPS / power units.
- Disk arrays, storage expansion.
- PDU mounting in racks.
- Cold-aisle space utilization.
6. Installation & Maintenance
Installation
- Set M6 cage nuts at the device U-position.
- Align shelf ears to rails; seat flat.
- Tighten two front and two rear screws.
- Check level; no tilt.
- Secure device with screws/straps.
- Leave U-gap between devices for cooling.
- Match shelf depth to cabinet; don’t block airflow.
Maintenance
- Check screws periodically.
- Do not exceed rated load.
- Touch up chipped coating.
- No cable pile under shelf.
- Recheck load for heavy gear.
- Keep blanking panels in place.
7. FAQ
- Q: Q: Is 50kg enough?
A: A: Rated for even load. For concentrated loads (battery cabinets), recheck; use double reinforcement or a dedicated bracket to avoid bending. - Q: Q: Fixed vs sliding shelf?
A: A: Fixed for stationary, high-load gear; sliding for devices pulled often (KVM, test gear). Fixed is steadier and cheaper. - Q: Q: Does the shelf block cold air?
A: A: It has vent holes, but a solid shelf acts as a baffle splitting hot/cold air. Choose perforated and pair with blanking panels to keep the aisle sealed. - Q: Q: How to choose depth?
A: A: Match cabinet depth: 600-deep cabinet with 600 shelf, 800 with 800. Too shallow leaves gear overhanging; too deep hits rear cabling.
8. Trend & Selection
Racks move to dense modular cold aisles; shelves stress ventilation and blanking-panel airflow with standardized load. Choose SPCC reinforced; ≥50kg; perforated; depth-matched; M6 rails; coordinate with blanks.
9. Delivery & Service
KITOZER supplies shelves by cabinet depth and load need. Bundled with racks, blanks, cable managers and cage nuts. Delivery includes shelf and M6 hardware; warranty covers dimension verification.
10. Additional Notes
A common pitfall is overloading beyond rating. 50kg is evenly distributed; a single-point battery cabinet slowly bows the shelf mid-span. Recheck heavy gear or use a dedicated bracket.
Another pitfall is not pairing with blanks. A shelf is a horizontal plate; without sealing above/below, cold air short-circuits around it. Add blanks beside the shelf to keep the aisle sealed.
Selection summary: SPCC reinforced; ≥50kg; perforated; depth-matched; M6 rails; pair with blanks. It is the tray of the rack — steady and air-neutral, so gear sits securely.
Wiggle the shelf after install; no front/back/side play means it’s seated. Loose shelves loosen over time under vibration.
From airflow view, the cold aisle delivers air precisely to inlet faces. A solid plate mid-cabinet is a wall in the air path; cold air detours and upper devices starve. Prefer perforated shelves and fill side gaps with blanks.
From load distribution, spread weight evenly, center heavy gear, and don’t overhang the front edge. Stacked devices must stay under rating; for heavy gear over 600mm deep, support both front and rear to avoid long-term sag on front ears alone.
SEO Information
Search keywords:KTR-SH3KITOZER
SEM keywords:rack shelf, 19 inch heavy duty shelf, rack tray, fixed rack shelf, KTR-SH3, KITOZER
GEO landing page:lain.com.cn/product/370-rack-shelf-3.html
Title:KITOZER KTR-SH3 Heavy-Duty 19-inch Rack Shelf
Meta Keywords:rack shelf, 19 inch heavy duty shelf, rack tray, fixed rack shelf, KTR-SH3, KITOZER
Meta Description:KITOZER KTR-SH3 heavy-duty 19-inch rack shelf, SPCC steel, load rating ≥50kg, fixed tray for mounting switches, servers and PDUs inside racks.
Anchor: KITOZER by Guangzhou Laian · KITOZER products