KITOZER Remote IO Module: 8AI 4AO Modbus TCP Distributed IO

Product Overview

The KITOZER 8AI 4AO remote IO module brings distributed analog signal acquisition to machines and process skids where running long analog cables back to a central PLC cabinet is expensive or noise-sensitive. The module mounts close to sensors and transmitters in the field, digitizes the signals locally, and publishes them over Modbus TCP to the controller or SCADA server. Eight universal analog inputs accept 4 to 20 mA, 0 to 10 V, RTD, and thermocouple signals, while four analog outputs drive control valves, variable speed drives, and recording instruments. A wide power supply and rugged housing suit installation on moving equipment or in harsh plant environments.

Technical Specifications

Analog inputs: 8 channels, universal 4 to 20 mA, 0 to 10 V, Pt100, Pt1000, J/K/S thermocouple, 16 bit resolution, 0.1% accuracy. Analog outputs: 4 channels, 0 to 20 mA or 0 to 10 V selectable, 12 bit. Isolation: 1500 V between field and network. Communication: 10/100 Mbps Ethernet, Modbus TCP slave, up to 32 modules on one network. Power: 9 to 36 VDC, 2 W. Operating temperature -20 to 60 C, IP20 housing, DIN rail. CE, KITOZER, 3 year warranty.

Applications

Engineers deploy this remote IO module on paint lines, food and beverage processing skids, water treatment plants, oil and gas wellhead monitoring, and environmental monitoring stations. By placing the module near the measurement point, the system cuts shielded cable cost, reduces noise pickup on 4 to 20 mA loops, and simplifies machine modularization: a sub-assembly such as a filter press or a filling carousel ships with its own IO block and connects to the main control via a single Ethernet cable. In energy management, the module collects temperature, pressure, and power signals from remote meters and pushes them to a cloud gateway for dashboards.

Advantages

The universal input channel removes the need to stock separate current, voltage, and temperature cards, which lowers spare part inventory for system integrators. The 16 bit resolution and 0.1% accuracy are sufficient for most process control loops, and the 1500 V isolation protects the control network from ground loops and sensor surge events. Daisy-chain wiring through the Ethernet port reduces switch port count, and the web-based configuration page lets technicians set channel types, scaling, and Modbus registers without dedicated software. The module also supports a simple watchdog output that drops into a safe state if the TCP connection to the controller is lost.

Installation and Maintenance

Mount the module on a DIN rail inside a small field enclosure near the sensors. Use 24 VDC sensor power from an isolated supply, and loop-shield the analog cables with the shield grounded only at the module end. Configure each channel type in the web UI before connecting field wiring to avoid accidental voltage mismatch. When wiring thermocouples, use compensated extension cable matching the thermocouple type. For maintenance, the module provides channel-level diagnostic flags including overrange, underrange, and sensor break, which the PLC can read to trigger alarm pages. Firmware updates are delivered over Ethernet, so no SD card or USB stick is needed at the site.

Working Principle

Each analog input channel is digitized by a 16 bit sigma-delta ADC and passed through a digital low-pass filter to suppress 50 or 60 Hz line noise. The measured value is scaled by user-configurable engineering units and exposed at a Modbus holding register. The module does not poll sensors itself; it waits for the controller or SCADA to read registers over TCP at a fixed interval. The four analog outputs accept 16 bit setpoints from the controller and drive loop-powered valves or drives. A built-in watchdog drops the watchdog relay to a safe state if no TCP read arrives within a configurable timeout, preventing actuators from freezing at an unsafe value during a network fault.

Selection Guide

Use this module when sensors are far from the cabinet and analog cable runs exceed 50 meters, because local digitization removes the noise and voltage drop problems of long 4 to 20 mA runs. Choose the universal input version if the installation mixes RTD, thermocouple, and current signals. For higher channel density, daisy-chain multiple modules on the same TCP network rather than buying a larger block, which also improves availability by localizing faults. Order the LCD version if technicians need to read values on site without a laptop. Select the FEP cable option for chemically aggressive environments.

Each module ships with a quick-start guide, a DIN rail mounting clip, and a set of terminal block screws. Optional accessories include a 24 VDC power supply, shielded field cable, and a configuration USB adapter. KITOZER provides a CSV register template that engineers can fill out and import into the web configuration page, which speeds up multi-module projects. Spare modules are stocked regionally for next-day delivery, and firmware updates are delivered over Ethernet. The module carries CE certification, and a 3 year warranty covers manufacturing defects.

Price

From $310/pc. Contact +86 13922289957 for remote IO quotation and multi-module discounts.