KITOZER
KITOZER

KITOZER Remote IO: 8 Channel Analog Input Modbus RTU Module

Product Overview

The KITOZER KT-RIO8AI is a distributed remote I/O module that brings analog signal acquisition directly into the field, reducing long wiring runs from sensors back to the control cabinet. Eight analog input channels accept 4 to 20 milliampere and 0 to 10 volt signals, and each channel is individually configurable through dip switches or software. The module communicates over RS485 Modbus RTU at baud rates up to 115200, and a built-in terminal resistor simplifies bus termination at the end of the line. This makes KT-RIO8AI an ideal companion for PLCs, data loggers, and building management systems that need to gather temperature, pressure, level, and flow signals from remote equipment skids.

Technical Specifications

Eight analog input channels, 16 bit resolution, configurable for 4 to 20mA, 0 to 20mA, 0 to 10V, 0 to 5V, PT100, and thermocouple types J, K, and T. Common mode rejection ratio exceeds 86 decibels at 50 and 60 hertz, and sampling time per channel is 10 milliseconds. The module draws 120 milliamperes at 24V DC and offers 3000V AC isolation between field wiring and the communication bus. Baud rate is selectable from 1200 to 115200, with Modbus address adjustable via rotary switches. Operating temperature spans minus 20 to plus 60 degrees Celsius, and the DIN-rail plastic housing is rated IP20. CE and RoHS certifications are standard.

Applications

Typical installations include pumping stations where pressure transmitters and level sensors are spread across a site, and a single twisted pair returns all signals to the master PLC. Food and beverage lines use the module to collect temperature from ovens and freezers located far from the control cabinet. Environmental monitoring, HVAC plant rooms, and energy metering panels also rely on the KT-RIO8AI to aggregate analog measurements before forwarding them to a SCADA or cloud gateway. Because the channels are software configurable, one module type can replace multiple specialized cards, simplifying spares inventory.

Advantages and Features

The KT-RIO8AI eliminates the cost of running individual shielded pairs from every sensor to the central cabinet, cutting installation labor and material expense. Each channel carries independent surge and overvoltage protection, so a fault on one loop does not pull down the whole module. The modular DIN-rail form factor snaps onto the same rail as circuit breakers and power supplies, keeping cabinet layout tidy. Free configuration software is provided for channel mapping, scaling, and Modbus register table export, and a diagnostic LED indicates bus activity, power, and per-channel overrange. Up to 32 modules can share one RS485 segment, and the module is backed by a 3 year warranty.

Installation and Maintenance

Mount the module on a standard 35 millimeter DIN rail, and wire the RS485 bus in a daisy-chain topology rather than a star. Enable the 120 ohm termination only at the two physical ends of the segment. Power the module from a regulated 24V DC supply, and keep the common ground separate from noisy motor drives. Use shielded twisted pair cable, grounding the shield at the cabinet entry. During commissioning, set the Modbus address with the rotary switches, then scan the bus with the configuration tool to verify each channel. For maintenance, the removable screw terminals allow field wiring to stay intact while the module is swapped out, minimizing downtime. Store spare modules in their original packaging to protect the analog front end from electrostatic discharge.

Reliability and Testing

Each KT-RIO8AI is factory calibrated at five points across the input range and temperature cycled from minus 20 to plus 60 degrees Celsius to verify drift stays within specification. Independent channel isolation means a single shorted loop cannot take down the module, and the built-in watchdog resets the communication port if the firmware hangs. Surge protection on each RS485 wire survives 2kV contact discharge, which is critical in plants with heavy motor switching.

Industry Standards and Compliance

The KT-RIO8AI conforms to IEC 61010-1 for measurement, control, and laboratory use, and its EMC immunity meets IEC 61326-1 industrial locations. Modbus RTU implementation follows the Modbus Organization specification, register mapping documented in the user manual. The unit is CE marked and RoHS compliant, and UL certification is in progress for North American panels. Because the channels are optically isolated, the module complies with IEC 61131-2 sensor wiring rules. KITOZER supplies the declaration of conformity and installation drawing in digital format on request.

Why Choose KITOZER

KITOZER remote IO modules are priced at roughly half the cost of equivalent imported brands, yet offer the same Modbus register mapping and DIN-rail form factor. This makes them a direct drop-in replacement for existing systems when legacy modules reach end of life. The configuration software is a free download, and a 30 day evaluation period lets integrators prove performance on their own bench. Bulk orders above 100 units qualify for volume pricing and a dedicated account engineer. KITOZER maintains a 5000 unit stock for the most popular variants, ensuring same-week delivery.

Warranty and Support

The KT-RIO8AI carries a 3 year warranty and a 30 day no-questions-asked return policy for evaluation units. KITOZER engineers help with Modbus register mapping and wiring diagrams at no charge, and provide a sample PLC program for common use cases. Spare modules ship within 24 hours for critical orders. A free webinarseries covers configuration, troubleshooting, and best practices for distributed IO. Calibration certificates and test reports are available on request with every shipment.

Price

From $185/pc including configuration software. Contact +86 13922289957 for bulk pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com